Operating Instructions

LASER RADIATION
DO NOT STARE INTO BEAM!
CLASS IIIa LASER PRODUCT
MAX. OUTPUT < 5 mW, WAVELENGTH 635 – 660 NM
RoHS
5020-0450

Advertisement

loading
Need help?

Need help?

Do you have a question about the ScanTemp 450 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ITS Telecom ScanTemp 450

  • Page 1: Operating Instructions

    Operating Instructions LASER RADIATION DO NOT STARE INTO BEAM! CLASS IIIa LASER PRODUCT MAX. OUTPUT < 5 mW, WAVELENGTH 635 – 660 NM RoHS 5020-0450...
  • Page 2 Table of emissivity values Table of emissivity values of common materials: Aluminum* 0.30 Asbestos 0.95 Asphalt 0.95 Basalt 0.70 Brass* 0.50 Brick 0.90 Carbon 0.85 Ceramic 0.95 Concrete 0.95 Copper* 0.95 Dirt 0.94 Frozen food 0.90 Hot food 0.93 Glass (plate) 0.85 0.98 Iron*...
  • Page 3 • Please keep this instruction manual for future refer- ence. 2. Field of operation and all the benefits • The ScanTemp 450 infrared thermometer is a non-contact infrared thermometer with Thermocouple connector. For the infrared part, simply aim the thermometer at the target and press the measurement button to display the surface temperature in less than a second.
  • Page 4 • Do not place your device near extreme temperatures, vibrations or shocks. • The ScanTemp 450 should be stored at room tempera- ture between –20 to +65°C. • The lens should be kept clean at all times.
  • Page 5 ScanTemp 450 – Infrared Thermometer • The sensor lens is the most delicate part of the ScanT- emp. The lens should be kept clean at all times, care should be taken when cleaning the lens using only a soft cloth or cotton swab with water or medical alcohol, allowing the lens to fully dry before using the ScanTemp 450.
  • Page 6 ScanTemp 450 – Infrared Thermometer Default Screen Infrared function ScanTemp 450 is supplied with a default emissivity of 0.95. ④ → Press Mode key for scrolling more display function as follows: ④ Press emissivity key key to adjust the emissivity.
  • Page 7 ScanTemp 450 – Infrared Thermometer ➞ ScanTemp 450 will automatically shut off if left idle for more than 12 min in PRB mode. ➞ The measurement range: -64 to +1400 °C. After measure high temp, the probe may remain HOT for a while.
  • Page 8 ➞ For all other error messages it is necessary to reset the ScanTemp 450. ➞ To reset the ScanTemp 450, please wait the instrument automatic off, remove the battery and wait for a minimum of one minute, re- insert the battery and turn on.
  • Page 9 ScanTemp 450 – Infrared Thermometer 7. Waste disposal This product has been manufactured using high-grade materials and components which can be recycled and reused. Never dispose of empty batteries and rechargeable batteries in household waste. As a consumer, you are legally required to...
  • Page 10 ScanTemp 450 – Infrared Thermometer Operating range: 0 to +50 °C (32 to 122°F) Storage range: -20 to +65 °C (-4 to 149 °F), 95%RH Response time: 1sec Distance to Spot size: 12:1 Emissivity: 0.10~1.00 step 0.01 Update frequency: 1.4Hz...