PVLB10/ PVLC10 Serial Bus Modules V-382P Contents DeviceNet™ ..........................3-4 ® PROFIBUS-DP ..........................5 InterBus-S ® ............................. 6 ® ............................. 7-8 WARNING BEFORE SERVICING THIS UNIT! Hazardous voltages and fluid pressures may be present. Disconnect all external power, BUS connections and air supply prior to the servicing of this device.
This device transmits 2 bytes and receives 2 bytes. The EDS file can be downloaded from our website http://www.parker.com/pneumatic. Click on Solenoid / Air Operated Valves and then click on PVLB10 or PVLC10 Valves and finally click on Service / Maintenance. Bus Connector...
Page 4
PVLB10/ PVLC10 Serial Bus Modules V-382P ™ DeviceNet Module Status Lights (LED's) Baud Rate Setting Through DIP Switches Indicator Description Baud Rate SteadyGreen Normal Power-BUS 125 Kbaud No Power Applied to the BUS 250 Kbaud Steady Green Normal Power-Out No Power Applied to the...
No Power Applied A Line Last Module Termination B Line If the PVLB10 or PVLC10 manifold is the last device on the network, a terminating resistor connector must be connected on the Bus-OUT connector. If the network baud rate is Bus-Out Connector higher than 1.5 Mbaud, use a terminating resistor connector...
PVLB10/ PVLC10 Serial Bus Modules V-382P InterBus-S E STOP Feature* Output power to the solenoids can be wired to allow the user to turn the outputs off while allowing the communications to Technical Specifications remain on. This can be done by placing the user's External Power Supply .........
Page 7
PVLB10/ PVLC10 Serial Bus Modules V-382P Technical Specifications Module Status Lights (LED's) Bus Voltage ..........29.5-31.6 VDC Indicator Description Bus Current ..............30mA ASI Bus Error Output Current ............250mA Steady Green Normal Total Output Current ............1A No Power Max.
Page 8
PVLB10/ PVLC10 Serial Bus Modules V-382P Pinout Details External Power Connector ASI Bus Connector Function Function 24 VDC Valve Power 0 VDC Input Connector (On PVLBAXXXXX Modules PNP Only) Function 24 VDC 0 VDC Input Valve Address & Input Mapping...