Mantel Clearance - Superior Fireplaces VRT3042 Quick Start Manual

Vent-free fireplaces

Advertisement

Cat. #
Model
F0306
VRT3042B
F0307
VCT3042B
F0316 VRT3042WS Radiant
F0317 VCT3042WS
F0318
VRT3042RS
F0319
VCT3042RS
F0320
VRT3042RH
F0321
VCT3042RH

Mantel Clearance

Wall board or facing
material (above
firebox) may be of
combustible material,
including decorative
mantel ornaments or
other similar projec-
tions off of the facing
material.
Framing
Material
Firebox
Wire-mesh
Screen
Mantel from Top of Opening
12" (305 mm)
16" (407 mm)
20" (508 mm)
Nails or Wood
Screws
Nailing Flange
Printed in U.S.A. © 2016 Innovative Hearth Products
P/N 900660-02 REV. NC 04/2016
VRT3042 AND VCT3042
Type
Interior
Weight
Radiant
Black
224 lb.
Louver
Black
224 lb.
WS refractory
224 lb.
Louver
WS refractory
224 lb.
Radiant
RS refractory
224 lb.
Louver
RS refractory
224 lb.
Radiant
RH refractory
224 lb.
Louver
RH refractory
224 lb.
Mantel Shelf
Note: Any portion of the
Inch (millimeter)
mantel shelf must NOT
extend beyond this profile.
12 (305)
6-3/4 (172)
1-1/2 (38)
Noncombustible
16
Material May
(407)
Project Off this
Surface above
12
the Firebox Hood
(305)
Note: All vertical
measurements are
Supplied
from top of fireplace
Firebox Hood
hood opening to
Must Be Used
bottom of mantel shelf.
at All Times
These minimum
clearances replace any
other recommended
clearances supplied
with your ANSI Z21.11.2
approved gas logs.
Mantel Depth Allowed
1-1/2" (38 mm) max.
6-3/4" (172 mm) max.
12" (305 mm) max.
Cu. Ft.
32
32
32
32
32
32
32
32
20
(508)
Minimum Wall and Ceiling Clearances
A. Clearances from the side of the fireplace cabinet to any combustible
material and wall should follow diagram shown here.
Example: The face of a mantel, bookshelf, etc. is made of combustible
material and protrudes 3-1/2" from the wall. This combustible material
must be 4" from the side of the fireplace cabinet.
B. Clearances from the top of the firebox opening to the ceiling should not
be less than 42".
C. When the firebox is installed directly on carpeting, vinyl tile or other
combustible material, other than wood flooring, the firebox should be
installed on a metal or wood panel extending the full width and depth of
the enclosure.
D. Clearances from the bottom of firebox to the floor is 0".
PFS
These appliances comply with National
Safety Standards and are listed by PFS Cor-
®
poration to ANSI Z21.91 Ventless Firebox
C
US
Enclosures for Gas-Fired Unvented Decora-
tive Room Heaters and is approved for use
with appliances listed to ANSI Z21.11.2
Report No. F12-020
decorative type unvented room heaters.
Inch (millimeter)
Example
1/2
1
2
4
6
8
10
(13)
(26)
(51)
(102)
(153)
(204)
(254)
CORNER
INSTALLATION
INTERNAL WALL
INSTALLATION
FULL
PROJECTION
INSTALLATION
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Specifications and clearances are subject to change without notice.
Refer to Installation and Operation Manual before installation of these
appliances for updated dimensions and instructions.
12-1/4 (312)
10-1/2 (267)
8-3/4 (223)
7 (178)
5-1/4 (134)
3-1/2 (89)
1-3/4 (45)
7/8 (23)
1/2 (13)
12
14
16
(305)
(356)
(407)
FLUSH
INSTALLATION
Page 2 of 2