1.
Specifications:
Hardware:
‧Model:SC1150A-30
‧MCU:PIC16F685
‧Power Transfer:AC/DC Switching Power Supply
‧Input Voltage:100~240VAC 50/60HZ
‧Output Current:5A(Max)
‧Output Voltage:21~29.2V
‧DC-cord Jack:Microphone Head
‧Storage Temperature:-20~85℃
‧Operating Humidity:20%~80%RH
‧Operating Temperature:0~40℃
‧Heat dispersion:By Fan in CC-CV Mode
‧Dimension:180*95*51 mm
‧Weight:1000g
‧Certification:UL、TUV、JQA、SAA
Instruction:
Charging Control
Charging Mode:
﹣CC, CV and floating charge 3 stages
‧LED Indicator status:
﹣Stand-by、Charging、Floating charging、
Temperature Stand-by、Finish、NG
Protection:
‧Battery Over Voltage Protection:
﹣Charge-inhibition as battery voltage abnormal high
‧Battery Low Voltage Protection:
﹣Charge-inhibition as battery voltage abnormal low
‧Over Load Protection:
﹣Charge-inhibition
‧Over Temperature Protection:
﹣Charge-inhibition as fan breakdown or other abnormal
﹣Fan starts if floating charge temperature abnormal high
‧Short-Circuit Protection:
﹣Charge-inhibition
‧Max charging time protection:
﹣Max CC-CV charging time 12 hours
﹣Max Floating charging time 2 hours
‧No Output Protection:
﹣As no battery connection
‧Reverse Polarity Protection:
﹣staying in standby mode, no charge action
‧Delayed Charging Protection:
﹣3 seconds delay to start charging after charger
connects to batteries.
‧Auto-identify Battery Capacity Protection:
﹣Capacity>36AH, auto-extend max time protection
﹣Capacity<36AH, auto-decrease CC charging current
1
SC1150A-30

Advertisement

loading

Summary of Contents for SAC SC1150A-30

  • Page 1 SC1150A-30 MCU Lead-Acid Battery Charger of Intelligent 3 stage distinct operating mode : Specifications: Hardware: Protection: ‧Model:SC1150A-30 ‧Battery Over Voltage Protection: ‧MCU:PIC16F685 ﹣Charge-inhibition as battery voltage abnormal high ‧Power Transfer:AC/DC Switching Power Supply ‧Battery Low Voltage Protection: ‧Input Voltage:100~240VAC 50/60HZ ﹣Charge-inhibition as battery voltage abnormal low...