MONTAGE
INSTALLATION
ID ISC.MRU200
MidRange Reader UHF
(deutsch / english)
final
public (B)
2012-03-08
M70201-4de-ID-B.doc

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for Feig Electronic OBID i-scan UHF ISC.MRU200

  • Page 1 MONTAGE INSTALLATION ID ISC.MRU200 MidRange Reader UHF (deutsch / english) final public (B) 2012-03-08 M70201-4de-ID-B.doc...
  • Page 2 ® OBID i-scan Montage ID ISC.MRU200 deutsche Version ab Seite 3 english version from page 28 FEIG ELECTRONIC GmbH Seite 2 von 52 M70201-4de-ID-B.doc...
  • Page 3 Hinweise jederzeit dankbar. Die in diesem Dokument gemachten Installationsempfehlungen gehen von günstigsten Rahmenbedingun- gen aus. FEIG ELECTRONIC GmbH übernimmt keine Gewähr für die einwandfreie Funktion in systemfrem- den Umgebungen. FEIG ELECTRONIC GmbH übernimmt keine Gewährleistung dafür, dass die in diesem Dokument enthal- tenden Informationen frei von fremden Schutzrechten sind.
  • Page 4: Table Of Contents

    4.3.3 Ethernet-Schnittstelle (ID ISC.MRU200-E) ..............16 4.3.4 USB-Schnittstelle (ID ISC.MRU200-USB) ..............17 Eingänge ........................17 Ausgänge ........................19 4.5.1 Optokoppler ........................ 19 4.5.2 Relais ......................... 20 Bedien- und Anzeigeelemente LEDs .......................... 21 T1: Reset-Taster ......................21 FEIG ELECTRONIC GmbH Seite 4 von 52 M70201-4de-ID-B.doc...
  • Page 5 ID ISC.MRU200 J1-J8: Schnittstellenkonfiguration ................22 X62: Bootloader Modus .................... 23 Technische Daten Zulassung ........................26 6.1.1 Europa (CE) ........................ 26 6.1.2 USA (FCC) ......................... 26 6.1.3 USA und Kanada (UL) ....................27 FEIG ELECTRONIC GmbH Seite 5 von 52 M70201-4de-ID-B.doc...
  • Page 6: Sicherheits- Und Warnhinweise - Vor Inbetriebnahme Unbedingt Lesen

    Obwohl dieses Gerät die zulässigen Grenzwerte für elektromagnetische Felder nicht überschreitet, sollten Sie einen Mindestabstand von 25 cm zwischen dem Gerät und Ihrem Herzschrittmacher einhalten und sich nicht für längere Zeit in unmittelbarer Nähe des Geräts bzw. der Antenne aufhalten. FEIG ELECTRONIC GmbH Seite 6 von 52 M70201-4de-ID-B.doc...
  • Page 7: Leistungsmerkmale

    Folgende Komponenten sind im Lieferumfang enthalten: 1 x Reader ID ISC.MRU200 8 x Kurzschlussbrücke (Jumper) 2 x Dichtverschluss M16 1 x Dichtverschluss M12 1 x Dichtverschluss-Reduzierstück 2 x Designblenden aufsteckbar 2 x Integrierte Deckelhalter FEIG ELECTRONIC GmbH Seite 7 von 52 M70201-4de-ID-B.doc...
  • Page 8: Montage

    M5 Stahl verzinkt DIN 84 / ISO 1207, Festigkeitskasse 8.8 oder Beton, Stein z.B. Kunst- stoffdübel 6mm mit Holzschraube DIN96 d=4mm). Der maximale Schraubenkopfdurchmesser be- trägt 8,5 mm 200 (7.87) 182 (7.16) Bild 3-1: Gehäuse ID ISC.MRU200 (alle Maße in mm (inch)) FEIG ELECTRONIC GmbH Seite 8 von 52 M70201-4de-ID-B.doc...
  • Page 9: Kabelverschraubungen

    Das beigelegte Dichtring-Reduzierstück ist für die Netzwerkanbindung bzw. das USB- Anschlusskabel vorgesehen. Das aufgeschlitzte Reduzierstück wird über die Netzwerkleitung bzw. das USB-Anschlusskabel gelegt und anschließend in der Kabelverschraubung fixiert. Bild 3-2: Netzwerkanbindung mit Dichtring-Reduzierstück FEIG ELECTRONIC GmbH Seite 9 von 52 M70201-4de-ID-B.doc...
  • Page 10: Deckelhalter

    Die Designblenden werden nach der Montage des Readers aufgesteckt. Die Nut an der Längsseite der Blende dient zur Demontage der Blende. Mit einem geeigneten Schraubendreher kann die Blende entfernt werden. Bild 3-4: Designblende FEIG ELECTRONIC GmbH Seite 10 von 52 M70201-4de-ID-B.doc...
  • Page 11: Anschlussklemmen Und -Buchsen

    Anschlussklemmen und -buchsen In Bild 4-1 und Bild 4-2 sind alle Anschlussklemmen und -buchsen, sowie die Bedien- und Anzei- geelemente für die Readertypen -USB bzw. -E dargestellt. Bild 4-1: Anschlussklemmen und -buchsen (Typ -A) FEIG ELECTRONIC GmbH Seite 11 von 52 M70201-4de-ID-B.doc...
  • Page 12: Versorgungsspannung

    Bei Anschluss der Geräte mit flexiblen Leitungen sind im besondern die Vorschriften nach NEC Artikel 400.7 (8) und Artikel 400.8 (1) – (7) Anzuwenden. Hinweis: Eine Verpolung der Versorgungsspannung kann zur Zerstörung des Gerätes führen. FEIG ELECTRONIC GmbH Seite 12 von 52 M70201-4de-ID-B.doc...
  • Page 13: Antennenanschlüsse

    Antennen mit Kabel darf 1,5:1 nicht überschreiten. Tabelle 4-2: Antennenanschluss Anschluss Beschreibung SMA-Buchse für Antennenanschluss ANT1, ANT2 (Eingangsimpedanz 50 Ω) ANT1 ANT2 Bild 4-4: Antennenanschluss Hinweis: Das maximale Anzugsdrehmoment der SMA-Buchsen beträgt 0,45 Nm. FEIG ELECTRONIC GmbH Seite 13 von 52 M70201-4de-ID-B.doc...
  • Page 14: Schnittstellen

    X2 / Pin 1 (GND) Pin 5 X2 / Pin 2 (RxD) Pin 3 X2 / Pin 3 (TxD) Pin 2 TxD RxD GND 9-pol. DUB-D-Buchse Bild 4-5: Verdrahtungsbeispiel für den Anschluss der RS232-Schnittstelle FEIG ELECTRONIC GmbH Seite 14 von 52 M70201-4de-ID-B.doc...
  • Page 15: Rs485- / Rs422-Schnittstelle (Id Isc.mru200-Usb)

    RS485/RS422 – (A -) X3 / Pin 3 RS485/RS422 – (B +) X3 / Pin 4 RS422 – (Y -) X3 / Pin 5 RS422 – (Z +) A- GND Bild 4-6: Anschlussbelegung der RS485-/RS422-Schnittstelle FEIG ELECTRONIC GmbH Seite 15 von 52 M70201-4de-ID-B.doc...
  • Page 16: Ethernet-Schnittstelle (Id Isc.mru200-E)

    255.255.255.0 Port 10001 Hinweis: Die Reader müssen nacheinander ans Netzwerk angeschlossen und konfiguriert werden. Jede IP-Adresse darf nur einmal im Netzwerk vertreten sein. Alternativ kann die Einstellung über die asynchrone Schnittstelle erfolgen. FEIG ELECTRONIC GmbH Seite 16 von 52 M70201-4de-ID-B.doc...
  • Page 17: Usb-Schnittstelle (Id Isc.mru200-Usb)

    Bild 4-7: Interne und mögliche externe Beschaltung der Optokopplereingänge Bei Versorgungsspannungen größer 10 V muss der Eingangsstrom durch einen weiteren externen Vorwiderstand (siehe Tabelle 4-8) auf max. 20 mA begrenzt werden. Tabelle 4-8: Externe Vorwiderstände FEIG ELECTRONIC GmbH Seite 17 von 52 M70201-4de-ID-B.doc...
  • Page 18 Verpolung oder Überlastung der Eingänge führt zu deren Zerstörung. • Die Versorgungsspannung des Readers darf nicht zur Ansteuerung der Eingänge ver- wendet werden, da es ansonsten durch zusätzlich eingestrahlte Störungen zu Einbußen in der Lesereichweite kommen kann. FEIG ELECTRONIC GmbH Seite 18 von 52 M70201-4de-ID-B.doc...
  • Page 19: Ausgänge

    • Die Ausgänge sind für max. 24 VDC / 30 mA ausgelegt. • Verpolung oder Überlastung der Ausgänge führt zu deren Zerstörung. • Die Ausgänge sind nur zum Schalten ohmscher Lasten vorgesehen. FEIG ELECTRONIC GmbH Seite 19 von 52 M70201-4de-ID-B.doc...
  • Page 20: Relais

    • Der Relaisausgang ist für max. 24 VDC / 2 A ausgelegt. • Der Relaisausgang ist nur zum Schalten ohmscher Lasten vorgesehen. Im Falle einer induktiven Last sind die Relaiskontakte durch eine externe Schutzbeschaltung zu schüt- zen. FEIG ELECTRONIC GmbH Seite 20 von 52 M70201-4de-ID-B.doc...
  • Page 21: Bedien- Und Anzeigeelemente

    Leuchtet bei einem Fehler im RF-Teil des Readers. Der Fehlertyp kann per Software über die Schnittstellen ausgelesen werden 5.2 T1: Reset-Taster Durch Betätigen des Tasters T1 wird am Reader ein Reset durchgeführt. FEIG ELECTRONIC GmbH Seite 21 von 52 M70201-4de-ID-B.doc...
  • Page 22: J1-J8: Schnittstellenkonfiguration

    RS422 -Y ⇔ RS422 -Z 500 Ohm RS485 + RS422 Z+ 120 Ohm RS422 Y- RS422 B+ RS485 - RS422 A- 500 Ohm Bild 5-1: Jumper der RS485-Schnittstelle Bild 5-2: Jumper der RS422-Schnittstelle FEIG ELECTRONIC GmbH Seite 22 von 52 M70201-4de-ID-B.doc...
  • Page 23: X62: Bootloader Modus

    5-4 ist die Funktion der Stiftleiste X62 beschrieben. Tabelle 5-4: Stiftleiste X62 Beschreibung offen keine Auswirkung nach Betätigen des Tasters T1 wird der Reader in den Bootloader Mo- kurzgeschlossen dus versetzt. FEIG ELECTRONIC GmbH Seite 23 von 52 M70201-4de-ID-B.doc...
  • Page 24: Technische Daten

    - 1 Relais (1 x Wechsler) • Eingänge - 1 Optokoppler max. 24 VDC / 20 mA • Schnittstellen - RS232 - RS485 / RS422 (wahlweise einstellbar) - Ethernet (TCP/IP) (ID ISC.MRU200-E) - USB (ID ISC.MRU200-A) FEIG ELECTRONIC GmbH Seite 24 von 52 M70201-4de-ID-B.doc...
  • Page 25 • Zulassung Funk - Europa EN 302 208 - USA FCC 47 CFR Part 15 • EN 301 489 • Sicherheit – Niederspannung EN 60950 UL 60950-1 - Human Exposure EN 50364 FEIG ELECTRONIC GmbH Seite 25 von 52 M70201-4de-ID-B.doc...
  • Page 26: Zulassung

    Changes or modifications made to this equipment not expressly approved by FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
  • Page 27: Usa Und Kanada (Ul)

    10.5 dBic. Antennas not included in this list or having a gain greater than 10.5 dBic are strictly prohibited for use with this device. The required antenna impedance is 50 ohms. Lists of Antennas: ID.ISC.ANT.U250/250-FCC ID.ISC.ANT.U170/170-FCC ID ISC.ANT.U270/270-FCC ID ISC.ANT.U600/270-FCC FEIG ELECTRONIC GmbH Seite 27 von 52 M70201-4de-ID-B.doc...
  • Page 28: Feig Electronic Gmbh

    Composition of the information in this manual has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips.
  • Page 29: Feig Electronic Gmbh

    4.3.4 USB Interface (ID ISC.MRU200-USB) ................ 42 Inputs ......................... 42 Outputs ........................44 4.5.1 Optocouplers ......................44 4.5.2 Relay .......................... 45 Operating and Display Elements LEDs .......................... 46 Reset Button ......................46 FEIG ELECTRONIC GmbH Page 29 of 52 M70201-4de-ID-B.doc...
  • Page 30: Feig Electronic Gmbh

    J1-J8: Interface configuration .................. 47 X62: Boot Loader Mode .................... 48 Technical Data Approval ........................51 6.1.1 Europe (CE) ........................ 51 6.1.2 USA (FCC) ......................... 51 6.1.3 USA and Canada (UL) ....................52 FEIG ELECTRONIC GmbH Page 30 of 52 M70201-4de-ID-B.doc...
  • Page 31: Feig Electronic Gmbh

    25 cm (10 inch) between the device and your cardiac pacemak- er and not stay in the immediate proximity of the device’s antenna for any length of time. FEIG ELECTRONIC GmbH Page 31 of 52...
  • Page 32: Features Of The Reader Family Id Isc.mru200

    1 x Reader ID ISC.MRU200 8 x jumper 2 x seal cap M16 1 x seal cap M12 1 x seal cap - reducer 2 x decorative cover, clip-on 2 x integrated cover stays FEIG ELECTRONIC GmbH Page 32 of 52 M70201-4de-ID-B.doc...
  • Page 33: Installation

    DIN 84 / ISO 1207, property class 8.8 or concrete, stone e.g. plastic anchor 6mm with wood screw DIN96 d=4mm). The maximum size of the screw head is 8.5mm (0.33”) 200 (7.87) 182 (7.16) Fig. 3-1: Housing ID ISC.MRU200 (all dimensions in mm (inch)) FEIG ELECTRONIC GmbH Page 33 of 52 M70201-4de-ID-B.doc...
  • Page 34: Cable Glands

    The reducing ring provided is intended for the network connection. The slotted reducer is placed over the network cable and then fixed in place in the cable gland. Fig. 3-2: network connection with slotted reducer FEIG ELECTRONIC GmbH Page 34 of 52 M70201-4de-ID-B.doc...
  • Page 35: Cover Stays

    The decorative covers are attached after installing the Reader. The slot on the long side of the cover is used for disassembling the cover. Use a screwdriver to remove the cover. Fig. 3-4: Decorative cover FEIG ELECTRONIC GmbH Page 35 of 52 M70201-4de-ID-B.doc...
  • Page 36: Terminals And Jacks

    Terminals and Jacks Fig. 4-1 and Fig. 4-2 show terminals, jacks and operating elements of reader type -USB respective- ly reader type -E. Fig. 4-1: Terminals, jacks and operating elements of Type -USB FEIG ELECTRONIC GmbH Page 36 of 52 M70201-4de-ID-B.doc...
  • Page 37: Supply Voltage

    Listed NEC Class 2/LPS supply, only. • by use of flexible cords, the NEC rules according article 400.7 (8) and 400.8 (1)-(7) must be applied. Note: Reversing the polarity of the supply voltage may destroy the unit. FEIG ELECTRONIC GmbH Page 37 of 52 M70201-4de-ID-B.doc...
  • Page 38: Antenna Connections

    SMA jacks for antenna connections ANT1, ANT2 (input impedance 50 Ω) ANT1 ANT2 Fig. 4-4: Antenna Connections ANT1 and ANT2 Note: The maximum tightening torque of the SMA sockets is 0,45 Nm (4.0 lbf in). FEIG ELECTRONIC GmbH Page 38 of 52 M70201-4de-ID-B.doc...
  • Page 39: Interfaces

    X2 / Pin 1 (GND) Pin 5 X2 / Pin 2 (RxD) Pin 3 X2 / Pin 3 (TxD) Pin 2 TxD RxD GND 9-pol. DUB-D-Buchse Fig. 4-5: Wiring example for connecting the RS232 interface FEIG ELECTRONIC GmbH Page 39 of 52 M70201-4de-ID-B.doc...
  • Page 40: Rs485 / Rs422 Interface (Id Isc.mru200-Usb)

    RS485 / RS422 – (B +) X3 / Pin 4 RS422 – (Y -) X3 / Pin 5 RS422 – (Z +) A- GND Fig. 4-6: Wiring the RSR485 / RS422 interface FEIG ELECTRONIC GmbH Page 40 of 52 M70201-4de-ID-B.doc...
  • Page 41: Ethernet Interface (Id Isc.mru200-E)

    The readers must be connected to the network and configured one after the other. Every IP- Address must be used only one time. Alternatively this configuration can be done with the asynchronous interface. FEIG ELECTRONIC GmbH Page 41 of 52 M70201-4de-ID-B.doc...
  • Page 42: Usb Interface (Id Isc.mru200-Usb)

    Fig. 4-7: Internal and possible external wiring of the optocoupler inputs For supply voltages of greater than 10 V the input current must be limited to max. 20 mA by an additional external series resistor (see Table 4-8). FEIG ELECTRONIC GmbH Page 42 of 52 M70201-4de-ID-B.doc...
  • Page 43: Feig Electronic Gmbh

    Reversing the polarity or overloading the inputs will destroy them. • The Reader supply voltage must not be used to drive the inputs, since otherwise additionally induced noise may reduce the effective reading range. FEIG ELECTRONIC GmbH Page 43 of 52 M70201-4de-ID-B.doc...
  • Page 44: Outputs

    • The outputs are configured for max. 24 VDC / 30 mA. • Reversing the polarity or overloading the outputs will destroy them. • The outputs are intended for switching resistive loads only. FEIG ELECTRONIC GmbH Page 44 of 52 M70201-4de-ID-B.doc...
  • Page 45: Relay

    / 2 A. • The relay outputs are intended for switching resistive loads only. If an inductive load is used, the relay contacts must be protected by means of an external protection circuit. FEIG ELECTRONIC GmbH Page 45 of 52 M70201-4de-ID-B.doc...
  • Page 46: Operating And Display Elements

    Comes on when there is an error in the RF section of the Reader. LED V4 (red) The error type can be read out via software over the RS232/RS485 interface 5.2 Reset Button Pressing the button T1 resets the reader. FEIG ELECTRONIC GmbH Page 46 of 52 M70201-4de-ID-B.doc...
  • Page 47: J1-J8: Interface Configuration

    RS422 - Y ⇔ RS422 - Z 500 Ohm RS485 + RS422 Z+ 120 Ohm RS422 Y- RS422 B+ RS485 - RS422 A- 500 Ohm Fig. 5-1: RS485 Interface Jumper Fig. 5-2: RS422 Interface Jumper FEIG ELECTRONIC GmbH Page 47 of 52 M70201-4de-ID-B.doc...
  • Page 48: X62: Boot Loader Mode

    The pin connector X62 can be closed with a jumper (2.0 mm). Table 5-4: pin connector X62 Description open no effect closed after pressing the button T1 the reader is in th boot loader mode FEIG ELECTRONIC GmbH Page 48 of 52 M70201-4de-ID-B.doc...
  • Page 49: Technical Data

    Inputs - 2 Optocouplers max. 24 VDC / 20 mA (galvanically isolated) • Interfaces - RS232 - RS485 / RS422 (selectable) - Ethernet (TCP/IP) (ID ISC.MRU200-E only) - USB (ID ISC.MRU200-USB only) FEIG ELECTRONIC GmbH Page 49 of 52 M70201-4de-ID-B.doc...
  • Page 50: Feig Electronic Gmbh

    - Europe EN 302 208 / EN 300 220 - USA FCC 47 CFR Part 15 • EN 301 489 • Safety - Low-Voltage EN 60950 UL 60950-1 - Human Exposure EN 50364 FEIG ELECTRONIC GmbH Page 50 of 52 M70201-4de-ID-B.doc...
  • Page 51: Approval

    Changes or modifications made to this equipment not expressly approved by FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
  • Page 52: Usa And Canada (Ul)

    10.5 dBic. Antennas not included in this list or having a gain greater than 10.5 dBic are strictly prohibited for use with this device. The required antenna impedance is 50 ohms. Lists of Antennas: ID.ISC.ANT.U250/250-FCC ID.ISC.ANT.U170/170-FCC ID ISC.ANT.U270/270-FCC ID ISC.ANT.U600/270-FCC FEIG ELECTRONIC GmbH Page 52 of 52 M70201-4de-ID-B.doc...