• Do not apply air or fluid pressures above the maximum published inlet pressures • Problems resulting from any of the above-mentioned situations will jeopardize warranty Automatic Safety Information • Use the equipment only for its intended purpose • Do not point spray gun at any part of body •...
Triggering air, atomizing air and fan control air (when applicable) must be Fittings supplied and regulated separately. The DUX Automatic spray gun uses push-lock • The fluid hose must have a regulator, style fittings as standard equipment. To attach the shut-off valve, and a filter prior to use.
The DUX Automatic spray gun features two desired fluid atomization is achieved. methods of fan control adjustment: 7. Adjust fluid flow as necessary to achieve desired results. For customer service call 888 DUX AREA (888 389 2732) Page 5...
AUTOMATIC Troubleshooting Problem Cause Solution 1. Remove triggering assembly 2. Insert screwdriver into rear of spray gun Coating leakage Needle packing is too tight 3. Turn fluid seal nut counter-clockwise 1/4 turn (refer out of tip of spray gun to page 9 for packing adjustment) 4.
AUTOMATIC Maintenance Guide The DUX Automatic spray gun is a precision Fluid Needle Removal tool that delivers superior finishing results and cost savings with each use. Optimal results require good handling and maintenance processes. NOTE: Due to the self-cleaning nature of the Daily cleaning, lubrication, and proper fluid tip and needle combination;...
Fluid Packing Adjustment To replace or change the fluid tips: The fluid packing in all DUX spray guns is set 1. Ensure the spray gun is depressurized. pre-determined specification during 2.
AUTOMATIC Maintenance (continued) To adjust the packing: 1. Ensure the spray gun is depressurized. 2. Unscrew the trigger housing from the main body by turning counter-clockwise and completely removing it, along with the fluid needle and trigger piston (See Figure 10).
Removal 1. Ensure the spray gun is depressurized. 2. Remove the air cap retaining ring air cap. 3. Remove the fluid tip using the DUX 10mm fluid tip driver. 4. Unscrew the trigger housing and fully remove it, along with the fluid needle and trigger piston from the main spray gun body (See Figure 14).
6. Lubricate the fluid needle as indicated in figure 6 and reinstall the trigger housing, along with the fluid needle and trigger piston. 7. Replace the fluid tip using the DUX 10mm fluid tip driver. NOTE: See page 12 to view order of packing Figure 19 components.
AUTOMATIC Fluid Seal Base B. Fluid Seal C. Fluid Seal O-Ring D. Fluid Seal Spacer E. Fluid Seal Nut The DUX Automatic spray gun can easily be Cleaning Guide cleaned in the following ways: Cleaning the DUX Automatic Flushing Daily...
410466 Air Cap, A1, Stainless Steel 410467 Air Cap, A2, Stainless Steel Tools 310112 Fan Control Valve w/locking ring 310174 Dux 10mm Fluid Tip Driver 310173 Dux Packing Tool 410606 Dux Multi-Tool Wrench 410522 Packing Driver 310310 Packing Pressure Gauge Page 13 For customer service call 888.389.2732...
Fitting for 3/8” Diameter Tubing Quick Disconnect/Push Lock Swivel Fluid Inlet Fitting for 3/8” Diameter Tubing Feed Type Automatic Manual adjustment or Automatic Fan Control adjustment (external air supply) Fan Control Inlet (Automatic Quick Disconnect/Push Lock Swivel Adjustment) Fitting for 1/4” Diameter Tubing...
AUTOMATIC DUX Standard Warranty DUX TECHNOLOGIES INC. WARRANTS TO CUSTOMER THAT ALL DUX TECHNOLOGIES INC. PRODUCTS (A) ARE FREE FROM DEFECTS IN MATERIALS OR WORKMANSHIP AND (B) MEET ALL APPLICABLE DUX TECHNOLOGIES INC. SPECIFICATIONS. THE FOREGOING WARRANTY WILL REMAIN IN EFFECT FOR ONE YEAR FROM THE DATE OF SALE.
Need help?
Do you have a question about the Automatic and is the answer not in the manual?
Questions and answers