2. INTRODUCTION & SPECIFICATION
A totally dry heat, no condensation, no gas, no fumes and no smell. Reaches maximum heat output within seconds of being turned on. Highly polished
aluminium reflector for maximum heat efficiency. Adjusts horizontally through 25° while mounted. Three settings, controlled by pull chain, allow the unit to
be on low, half or full power. Ideal for industrial or domestic applications. Suitable for indoor use or outdoor use, if weather protected.
Power: . . . . . . . . . . . . . . . . . . . 2000W
Input supply: . . . . . . . . . . . . . . . 230V 50Hz 13A
Dimensions (W x H x D): . . . . . 485 x 250 x 170mm
3. MOUNTING INSTALLATION
3.1
WALL MOUNTING (fig.1).
IMPORTANT! The following points should be noted: The heater
should always have a minimum clearance of 450mm from a
ceiling and at least 900mm from any object. Ensure that
mounting surface is capable of supporting the weight of the
heater.
3.2
Use the bracket (fig.1C) as a template, fix the metal bracket to
the wall by means of the four holes and appropriate fixings
(not supplied).
3.3
Secure the neck (fig.1B) to the heater head (fig.1A) using a
single bolt.
3.4
Next with the help of a second person holding the heater, bolt the
neck (fig1.B) to the wall bracket (fig.1C) using a nut, bolt and two
washers.
3.5
Adjust the angle of heater to direct heat where required.
4. OPERATION
Note: The infrared lamp is fragile and therefore it is important that it is not subjected to any unnecessary shocks or vibration and is not moved
when it is on or until cooled down.
WARNING! Ensure you read, understand and apply the safety instructions in Section 1 before using the heater.
4.1
Ensure the heater is at least 900mm from any object. The heater can be tilted from 0° to 25° set it to the required angle before switching
the heater on.
4.2
Plug in the heater and switch it on.
4.3
The heater has the following settings:
Position 0:
Off position.
Position l:
middle element only.
Position m:
Two outer elements.
Position H:
All three elements.
4.4
make sure the heater plug is disconnected from the mains supply before any cleaning is attempted. Also allow the heater to cool
completely. Do not use water or other liquids, or harsh abrasive cleaners to clean the heater.
4.5
Clean the exterior with a soft damp cloth with some mild detergent.
4.6
When the heater is no longer required, switch off and unplug the unit.
4.7
To replace any of the lamps, contact your authorised Sealey dealer.
4.8
IWMh2003.V2 is fitted with an tilt safety mechanism so that if for any reason the heater would be tilt beyond 25° the heater will
cut-out. Position the heater upright to turn the heater back on.
Recycle unwanted materials instead of disposing of them as waste.
All tools, accessories and packaging should be sorted, taken to a recycle centre and disposed of in a manner which is compatible
with the environment.
When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid waste
authority for recycling information.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
fig.1
Environmental Protection.
Sole UK Distributor, Sealey Group,
Kempson Way, Suffolk Business Park,
Bury St. Edmunds, Suffolk,
IP32 7AR
Original Language Version
www.sealey.co.uk
01284 757500
Web
sales@sealey.co.uk
01284 703534
email
IWmH2003.V2