LG LB-H306GSS0 Installation Manual page 11

Concealed duct air conditioner
Table of Contents

Advertisement

Indoor unit installation
Installation of Unit
Install the unit above the ceiling correctly.
CASE 1
POSITION OF SUSPENSION BOLT
• Apply a joint-canvas between the unit and duct
to absorb unnecessary vibration.
• Apply a filter Accessory at air return hole.
Dimension
A
B
C
Capacity
30 kBtu/h
36 kBtu/h
1232 1180 355 45.5 450
42 kBtu/h
48 kBtu/h
1282 1230 477
60 kBtu/h
CASE 2
POSITION OF CONSOLE BOLT
• Install the unit leaning to a drainage hole side
as a figure for easy water drainage.
• A place where the unit will be leveled and that
can support the weight of the unit.
• A place where the unit can withstand its
vibration.
• A place where service can be easily
performed.
(Unit:mm)
D
E
F
(G)
H
I
30
87
830 186
56
590
30
120 1006 294
Installation of Indoor, Outdoor Unit
A
B
(G)
H
Drainage hole
M10 Nut
X 4
M10 SP. washer
X 4
M10 washer
X 4
M10 washer
X 4
M10 SP. washer
X 4
M10 Nut
X 4
Installation Manual 11
(Local
supply)
(Local