Download Print this page

Packard 320725-753 Installation Instructions

Psc inducer motor housing assembly kit

Advertisement

Quick Links

NOTE: Read the entire instruction manual before starting the
installation.
This symbol → indicates a change since the last issue.
SAFETY CONSIDERATIONS
Installing and servicing of heating equipment can be hazardous
due to gas and electrical components. Only trained personnel
should install or service heating equipment.
Untrained personnel can perform basic maintenance functions
such as cleaning coils or cleaning and replacing filters. All other
operations should be performed by trained service personnel.
When working on heating equipment, observe precautions in the
literature, on tags, and on labels attached to the unit.
Follow all safety codes. Wear safety glasses and work gloves.
Have fire extinguisher available.
Recognize safety information. This is the safety-alert symbol
When you see this symbol on the furnace and in instructions or
manuals, be alert to the potential for personal injury.
Understand the signal words DANGER, WARNING, and CAU-
TION. These words are used with the safety-alert symbol. DAN-
GER identifies the most serious hazards which will result in severe
personal injury or death. WARNING signifies a hazard which
could result in personal injury or death. CAUTION is used to
identify unsafe practices which would result in minor personal
injury or product and property damage.
Before beginning any installation or modification, be sure the
main electrical disconnect switch is in the OFF position.
Electrical shock can cause personal injury or death.
Label all wires prior to disconnection when servicing con-
trols. Wiring errors can cause improper and dangerous
operation.
INTRODUCTION
This instruction covers installation of the permanent split capacitor
(PSC) inducer motor kit Part No. 320725-753 on models
340MAV, 345MAV, 350MAV, 490AAV, 58MCA, 58MSA, and
58MXA Condensing Gas Furnaces. See Table 1 for kit applica-
bility.
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book 1 4
PC 101
Catalog No. 565-826
Tab 6a 8a

Installation Instructions

Part No. 320725-753
.
Printed in U.S.A.
PSC Inducer Motor
Housing Assembly Kit
Cancels: IIK 340M-40-15
→ Table 1—Kit Usage
MODEL
SERIES
NUMBER
340MAV
350MAV
490AAV
C
340MAV
350MAV
D
490AAV
345MAV
101
58MCA
111
58MXA
121
58MCA
131
58MXA
58MSA
101
* For 060120 and 120-20 size units on models and series specified, use high
output PSC inducer motor housing assembly kit, Part No. 320725-754. For
060140 and 140-20 size units on models and series specified, use high output
PSC inducer motor housing assembly kit, Part No. 320725-755.
DESCRIPTION AND USAGE
Use this PSC inducer motor kit to replace a failed inducer motor
assembly.
This kit contains the following items:
Inducer assembly
Installation Instructions
NOTE: Inducer assembly consists of motor and fan, capacitor,
wheel, motor mount, inducer cover, inducer housing, vent cap, and
vent clamp.
INSTALLATION
Step 1—Remove Old Motor Assembly
1. Turn off gas and electrical supplies to unit.
2. Remove main furnace door.
3. Remove drain tube from inducer motor mounting cover plate.
4. Remove pressure switch tubes. (See Fig. 1.)
a. Remove tube attached to pressure switch from collector
box.
b. Remove tube attached to pressure switch from burner
enclosure and gas valve.
5. Remove screw securing pressure switch and capacitor to
inducer housing.
6. Disconnect motor lead connector at quick-connect.
7. Using backup wrench, disconnect gas supply pipe from gas
valve.
8. Remove wires from gas valve. Note location for reassembly.
9. Remove burner box cover.
10. Remove screws securing manifold to burner box.
Form 58M-39SI
Pg 1
IIK 340M-40-24
USED ON
A
B
All Sizes
All Sizes Except
060120 and 060140*
All Sizes Except
A
060120*
All Sizes
All Sizes Except
120-20 and 140-20*
All Sizes Except
120-20*
11-96
Replaces: 58M-37SI
11-96
1
1

Advertisement

loading

Summary of Contents for Packard 320725-753

  • Page 1: Installation Instructions

    Remove tube attached to pressure switch from collector This instruction covers installation of the permanent split capacitor box. (PSC) inducer motor kit Part No. 320725-753 on models b. Remove tube attached to pressure switch from burner 340MAV, 345MAV, 350MAV, 490AAV, 58MCA, 58MSA, and enclosure and gas valve.
  • Page 2 COMBUSTION-AIR INTAKE CONNECTION BURNER GAS VALVE ENCLOSURE AUXILIARY PRIMARY HEAT JUNCTION BOX EXCHANGER VENT OUTLET (BEHIND CELL INLET PANEL) CONDENSING HEAT CAP AND EXCHANGER CLAMP (BEHIND CELL (UNUSED INLET PANEL) DRAIN CONNECTION) PRESSURE SWITCH VENT OUTLET INDUCER MOTOR CONTROL CENTER CONDENSATE TRAP BLOWER...