Download Print this page

KLIK LEDpod 50 Installation Instructions

Advertisement

Quick Links

KLIK LEDpod™ 50 Installation Instructions
Ø 0.96"
1.34"
Ø 1.02"
Use a 25mm annular cutter
Aprx 2"
Pull a loop of wire through hole.
3
90°
Fit clip into place until the clamping
6
ends are equally centered over the
hole. Use the tool to center the clasp
until equal pressure can be felt and
inspect by eye.
The notch indicates
Light
the direction of the light,
direction
Asymmetrical LEDPods
Push LEDPOD in until it snaps into place
9
and the outer surface is flush with the outer
surface of the tube.
Prod the rim of the clear silicone IP Seal to
provide a tighter fit.
www.klikusa.com - sales@klikusa.com
Ø 25 ± 0.2mm
to bore hole.
(Use 1" in aluminum.)
Rotate retaining clips in as shown. Avoid
4
tangling or severing through wire.
Install Scotchlok connectors to the (0.75-1.5sq) red
7
and black wires. Connect the corresponding color
wires of the driver to the Scotchloks and assure the
clip is secured.
LEDPOD Removal Steps
Insert removal tool into the
1
2mm holes in the LEDPOD.
With firm pressure, rotate
the LEDPod 90°.
OD 1.75"
2.38"
Make sure drilled holes are
1
deburred and excess swarf
is removed from railing.
Thru.
wire
Apply pressure as shown to deform clip into place in a
5
circular motion. Avoid damaging the surface of tube
and tangling or severing through wire.
POSITIVE [ + ]: Red
NEGATIVE [ - ]: Black
CAREFULLY feed the Scotchloks to the left of
8
the clip and the driver to the right with the
driver connector hanging out. Ensure wires
are clear from where the LEDPOD is to fit.
Proceed to connect the LEDPOD.
Carefully peel back
2
the IP silicone seal
one side at a time.
Be sure to re-attach
the silicone seal ready
for reinsertion.
PAGE 1 OF 2
2
Feed through appropriate
wires (0.75-1.5mm²).
Carefully remove the LEDPOD
3
from the clip, ensuring not to
damage or disconnect wires in
the process.
32864-C.1

Advertisement

loading

Summary of Contents for KLIK LEDpod 50

  • Page 1 KLIK LEDpod™ 50 Installation Instructions Ø 0.96” OD 1.75” 2.38” 1.34” Make sure drilled holes are Feed through appropriate deburred and excess swarf wires (0.75-1.5mm²). is removed from railing. Ø 25 ± 0.2mm Ø 1.02” Use a 25mm annular cutter to bore hole.
  • Page 2 KLIK LEDpod™ Soft Start Relay Installation Instructions Aprx 2” To LEDPods 24VDC Supply OUTPUT Feed power wires INPUT through tubing Carefully pull out a Cut wires at the center loop of wire at the of the loop. first LEDPOD location.