Daikin FXLQ-M Engineering Data page 19

R-410a, floor standing type/concealed floor standing type
Table of Contents

Advertisement

EDUS39-600-F7_a
2-1
ACCESSORIES
Check to ensure the following accessories are included
with your unit.
Name
Drain hose
Quantity
1 set
Hose × 1
Metal clamp × 1

Shape
Name
Sealing pad
Quantity
1 pc.
#
Shape
Name
Leveling screw
Quantity
4 pcs.
%
Shape
2-2
OPTIONAL ACCESSORIES
Table 1
Remote controller
Wired type
FOR THE FOLLOWING ITEMS, TAKE SPECIAL
CARE DURING CONSTRUCTION AND CHECK
AFTER INSTALLATION IS FINISHED.
a. Items to be checked after completion of work
Items to be checked:
Are the indoor and
outdoor units fixed firmly?
Is the gas leak test
finished?
Is the unit fully insulated?
Does drainage flow
smoothly?
Does the power supply volt-
age correspond to that
shown on the name plate?
FXLQ-M / FXNQ-M
Insulation for
fitting
1 each
(3)For gas pipe

(4)For liquid pipe
Clamp
8 pcs.
$
[Other]
• Operation manual
• Installation manual
BRC1D71
If not properly done,
the following can
occur:
Units may drop, vibrate or
make noise.
insufficient cooling
Dripping condensate water
Dripping condensate water
Unit may malfunction or the
components burn out.
Are wiring and piping cor-
rect?
Is the unit safely grounded?
Is wiring size according to
specifications?
Is something blocking the
air outlet or inlet of either
the indoor or
outdoor units?
Are refrigerant piping length
and additional refrigerant
charge noted down?
b. Items to be checked at time of delivery
Also review the SAFETY CONSIDERATIONS on the previ-
ous page.
Items to be checked:
Did you explain about operations while showing the oper-
ation manual to your customer?
Did you hand the operation manual over to your customer?
2-3
NOTE TO THE INSTALLER
Be sure to instruct customers how to properly operate the
unit, especially cleaning filters, operating different func-
tions, and adjusting the temperature.) Have them carry out
operations themselves while looking at the manual.
3.
SELECTING INSTALLATION SITE
• Select an installation site that meets with your cus-
tomer's approval and where the following conditions
are satisfied: Floor is strong enough to bear the indoor
unit weight.
• Floor is not significantly inclined.
• Nothing blocks the air passage.
• Condensate can be properly drained.
• Sufficient clearance for installation and maintenance
can be ensured.
• Optimum air distribution can be ensured.
• No risk of flammable gas leakage.
• Piping between indoor and outdoor units is possible
within the allowable limit. (Refer to the installation man-
ual of the outdoor unit.)
WARNING
• If the supporting structural members are not strong enough
to take the unit's weight, the unit could fall out of place and
Check
cause serious injury.
• Do not install unit in an area where flammable materials are
present due to the risk of explosion resulting in serious
injury or death.
NOTE
• Install the indoor and outdoor units, power supply wiring
and connecting wires at least 3.5 ft. away from televisions
or radios in order to prevent image interference or noise.
(Depending on the radio waves, a distance of 3.5 ft. may
not be enough to eliminate the noise.)
Installation
Unit may malfunction or the
components burn out.
Danger of electric leakage.
Unit may malfunction or the
components burn out.
insufficient cooling
Refrigerant charge in the
system is not clear.
Check
18