Oksys ECOS-150 Use And Instruction Manual

Oksys ECOS-150 Use And Instruction Manual

Service station for a/c systems

Advertisement

Service station for A/C systems
ECOS-150
Use and Instruction Manual
Ecos-150 sw 1.x.x - ver. 1.0

Advertisement

Table of Contents
loading

Summary of Contents for Oksys ECOS-150

  • Page 1 Service station for A/C systems ECOS-150 Use and Instruction Manual Ecos-150 sw 1.x.x - ver. 1.0...
  • Page 2: Table Of Contents

    5.1 Hoses setting ..........................17 5.2 Information and statistics in use for the unit ..................18 6.Ordinary maintenance...........................18 6.1 Filter replacement..........................18 6.2 Oil replacement of vacuum pump....................18 7. Technical data............................19 8. Declaration of conformity........................20 Ecos-150 sw 1.x.x - ver. 1.0 Page 2/20...
  • Page 3: General Information For The User

    Use the unit in airy environments; During maintenance operations disconnect the unit from the electrical power. Avoid removing the connecting hoses if not necessary; in case always make a vacuum in the hoses before using again; Ecos-150 sw 1.x.x - ver. 1.0 Page 3/20...
  • Page 4: Warning Icons Used In The Present Manual

    The same procedure has to be followed for the refrigerant gas residual in the storage bottle. The exhaust oil drained from the pump is a specific waste and has to be collected according to the relevant regulations in force. Ecos-150 sw 1.x.x - ver. 1.0 Page 4/20...
  • Page 5: Installation And Preparing For Use

    2.2.2 Oil level checking of vacuum pump Check the level of hydraulic oil in the vacuum pump and, if necessary, fill up to the level (about half of the spy glass) Half of the level Ecos-150 sw 1.x.x - ver. 1.0 Page 5/20...
  • Page 6: Connection Of Tubes And Leak Test

    2.2.6 Position on an even surface During the operations, the unit must be located on a flat and leveled surface in order to correclty perform the weight measurements and in order to comply to the safety rules. Ecos-150 sw 1.x.x - ver. 1.0 Page 6/20...
  • Page 7: Use

    R134a Check oil levels (vacuum pump and new oil reservoir). After having turned on the unit, check the level of the refrigerant in the internal reservoir. 3.2 Description of the unit Ecos-150 sw 1.x.x - ver. 1.0 Page 7/20...
  • Page 8 Allows to access the max pressure valve Access to vacuum pump Allows the vacuum pump inspection Automatically releases pressure if max pressure Max pressure valve is reached. Allows to manually release NCG gases, if present Ecos-150 sw 1.x.x - ver. 1.0 Page 8/20...
  • Page 9: General Description Of The Working Cycles

    NCG's until the theoretical and the actual pressure comply. Note: if the value on the pressure gauge, on the opposite, is lower than the theoretical one, the gas quantity in the tank is too low. Ecos-150 sw 1.x.x - ver. 1.0 Page 9/20...
  • Page 10: Analytical Description Of The Working Cycles

    Using the buttons “UP” and “DOWN” you may choose the desired function and press ENTER to start Icon Meaning START: immediate start of AUTOMATIC and complete working cycle according to the parameters shown on display (all cycles performed at one time) (FOLLOWS) Ecos-150 sw 1.x.x - ver. 1.0 Page 10/20...
  • Page 11: Starting An Automatic Working Cycle

    If, on the opposite, you want to immediately perform the single cycle only, press ENTER 3.4.2.2 Recovery By selecting RECOVERY and pressing ENTER the unit carries out the refrigerant recovery from the A/C system and discharges the exhaust oil. Press ENTER Ecos-150 sw 1.x.x - ver. 1.0 Page 11/20...
  • Page 12: Vacuum

    (select this option only if the vacuum in the system has already been carried out) 3.4.2.5 Oil injection into A/C system By selecting icon OIL INJECTION, you access the oil injection selection menu Ecos-150 sw 1.x.x - ver. 1.0 Page 12/20...
  • Page 13: Dye Injection Into A/C System (Optional)

    “0” (see hereunder p “Setting the hose length” ) The refrigerant charging is carried out thanks to the pressure difference between the tank and the Note Ecos-150 sw 1.x.x - ver. 1.0 Page 13/20...
  • Page 14: Accessory Functions

    When the refrigerant level in the internal bottle reis too low, the units displays a warning message and it is necessary to recharge the bottle. Connect a R134a gas bottle to the high pressure service tube (red) Ecos-150 sw 1.x.x - ver. 1.0 Page 14/20...
  • Page 15: Load Cell Test

    At the end of the print out, the user is required to choose if the counters have to be reset to “0” or not. Press on ENTER to reset all counters or “EXIT” to maintain the existing data Ecos-150 sw 1.x.x - ver. 1.0 Page 15/20...
  • Page 16: Options Setting

    With “additional recovery” it is possible to set the duration of an additional recovery to be made after the “standard” recovery procedure has finished. Press ENTER Increase the extra recovery time by means of the buttons UP and DOWN Ecos-150 sw 1.x.x - ver. 1.0 Page 16/20...
  • Page 17: Basic Parameter Setting And Information

    NOTE: If the hose length is set to “0” (zero), at the end of the working cycle, the user will have to suction the gas residuals in the A/C system of the vehicle, instead of recovering them into the unit. Ecos-150 sw 1.x.x - ver. 1.0 Page 17/20...
  • Page 18: Information And Statistics In Use For The Unit

    - Check the oil level by means of the relevant sight glass (2). The level of the oil (when the pump is not working) should be at the middle of the sight glass. Ecos-150 sw 1.x.x - ver. 1.0 Page 18/20...
  • Page 19: Technical Data

    Tension(V/Hz) 230/50-60Hz Fuses 2 x 10A Overall dimensions 545x520x950 Package dimensions 565x540x1110 Net weight/Gross weight 55/65 Via Dell'Albereto 33/B 50041 Calenzano (FI) Italy www.oksys.com info@oksys.com Tel.:+39 055 8990665 Fax +39 055 8990665 Ecos-150 sw 1.x.x - ver. 1.0 Page 19/20...
  • Page 20: Declaration Of Conformity

    DICHIARAZIONE DI CONFORMITA' (Community directives about Machinery, Low Voltage Electrical Devices and Electro- magnetic Compatibility) Oksys srl Via Dell'Albereto 33/B - 50041 Calenzano (FI) (Italy) hereby declares that the following products: dichiariamo che i seguenti prodotti: R134 refrigerant recovery and recharge unit Unità...

Table of Contents