schmersal AZM 200 AS Operating Instructions Manual
schmersal AZM 200 AS Operating Instructions Manual

schmersal AZM 200 AS Operating Instructions Manual

Solenoid interlock

Advertisement

Quick Links

Operating instructions
Solenoid interlock
Operating instructions. . . . . . . . . . . . .pages 1 to 8
EN
Original
Content
1

About this document

1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 Target group: authorised qualified personnel. . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3 Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
3
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.2 Manual release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
3.3 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
4
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .4
5
5.1 Mode of operation of the safety outputs. . . . . . . . . . . . . . . . . . . . . .4
5.2 Magnet control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
5.3 Programming the slave address . . . . . . . . . . . . . . . . . . . . . . . . . . .4
5.4 Configuration of the safety monitor . . . . . . . . . . . . . . . . . . . . . . . . .4
6
6.1 LED display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
6.2 Diagnostic information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
6.3 Read-out of the parameter port . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
7
7.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
7.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
8
8.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
8.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
9
EU Declaration of conformity
1. About this document

1.1 Function

This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety switchgear. The operating
instructions must be available in a legible condition and a complete
version in the vicinity of the device.

1.2 Target group: authorised qualified personnel

All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical specifications for the
selection, mounting and integration of the components.

1.3 Explanation of the symbols used

Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.

1.4 Appropriate use

The products described in these operating instructions are developed
to execute safety-related functions as part of an entire plant or machine.
It is the responsibility of the manufacturer of a machine or plant to
ensure the correct functionality of the entire machine or plant.
The safety switchgear must be exclusively used in accordance with
the versions listed below or for the applications authorised by the
manufacturer. Detailed information regarding the range of applications
can be found in the chapter "Product description".

1.5 General safety instructions

The user must observe the safety instructions in this operating
instructions manual, the country specific installation standards as well
as all prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal
catalogues or in the online catalogue on the Internet:
www.schmersal.net.
The information contained in this operating instructions manual is
provided without liability and is subject to technical modifications.
There are no residual risks, provided that the safety instructions as well
as the instructions regarding mounting, commissioning, operation and
maintenance are observed.
EN
AZM 200 AS
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AZM 200 AS and is the answer not in the manual?

Questions and answers

Summary of Contents for schmersal AZM 200 AS

  • Page 1 4.1 General information for electrical connection....4 Further technical information can be found in the Schmersal Functions and configuration catalogues or in the online catalogue on the Internet: 5.1 Mode of operation of the safety outputs.
  • Page 2 2.3 Purpose - Cover screws: 0.7 ... 1 Nm (Torx T10) The AZM 200 AS with non-contact electronic safety sensors is designed Manual release (Y/N): for application in the AS interface Safety at Work and is used for Ambient conditions monitoring the position and blocking movable protective equipment.
  • Page 3 2.5 Safety classification of the interlocking function personnel. Standards: ISO 13849-1, IEC 61508 Control Category: For fitting the AZM 200 AS solenoid interlock, two mounting holes for PFH: 4 x 10 M6 screws with washers (washers included in delivery) are provided. SIL: suitable for SIL 3 applications The solenoid interlock must not be used as an end stop.
  • Page 4 0 of the addressed AS-i slave AZM 200 AS. In the power to lock variant of the AZM 200 AS, the functional set of output bit 0 will cause the solenoid interlock to be locked.
  • Page 5 Error The "safety release" status signal from a Safety at Work slave can be Errors, which no longer guarantee the function of the AZM 200 AS cyclically queried by the control system through the AS-i master. To that solenoid interlock (internal error)s cause the safety outputs to be effect, the 4 input bits with the varying SaW code of a Safety at Work disabled within the risk time.
  • Page 6 Operating instructions Solenoid interlock AZM 200 AS 6.3 Read-out of the parameter port The parameter port P0 to P3 of a solenoid interlock can be read out through the control interface of the AS-i master (see component description) by means of the "Write parameter" instruction (with hexadecimal value F).
  • Page 7 Solenoid interlock AZM 200 AS 9. EU Declaration of conformity EU Declaration of conformity Original K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives.
  • Page 8 K.A. Schmersal GmbH & Co. KG Möddinghofe 30, 42279 Wuppertal Germany Phone: +49 202 6474-0 Telefax: +49 202 6474-100 E-Mail: info@schmersal.com Internet: www.schmersal.com...

Table of Contents