• Do not carry the tool by the cable.
Do not unplug the cable by tug-
ging on it. Keep the cable away
from heat, oil and sharp edges.
• Connect the appliance to a pow-
er socket with a residual current
circuit breaker of rated residual
current no more than 30 mA.

Residual risks

Even if properly operating and han-
dling this electric tool, some residual
risks will remain. Due to its construc-
tion and build, this electric tool may
present the following hazards:
a) Cuts
b) Ear damage if working without
ear protection.
c) Damage to your health caused
by swinging your hands and
arms when operating the appli-
ance for longer periods of time
or if the unit is not held or main-
tained properly.
Warning! During operation,
this electric tool generates an
electromagnetic ield which,
under certain circumstances,
may impair the functionality
of active or passive medical
implants. To reduce the risk of
serious or lethal injuries, we
recommend that persons with
medical implants consult their
doctor and the manufacturer
of their medical implant before
operating the machine.
10

Assembly instructions

Always disconnect the tool
from the mains before con-
ducting any work on it.
While assembling the tool,
make sure that the mains
cable (2) does not become
caught and has enough slack.

Mounting the handlebars

(pre-mounted)
1. Fasten the central bar (3) onto
B
the lower bar (4). Use a screw,
quick-release lever and washer
(11) to fasten.
2. Attach the handlebar (1) to the
central bar (3). Use a screw,
quick-release lever and washer
(11) to fasten.
When properly mounted, the ends
of the handlebar will point away
from the front of the appliance (see
illustration
3. Fasten the mains cable (2) with
the cable clip supplied (10).
Position the cable clamp (10) on
the upper end of the centre spar
(3). Press the cable clamp (10)
onto the centre spar (3) and slide
the cable clamp (10) onto the
round part of the centre spar (3).

Operation

Observe noise-abatement laws and
local by-laws.
).
A