2.2.2 Digital output

Both digital device outputs can switch resistive, capacitive and inductive loads. The current is
automatically limited to these functions.
The following must be observed for inductive loads (e.g. relays): Inductivities up to 32 H can be
switched off without the D
inductivities.
If a freewheeling diode D

2.2.3 Digital input

The device has 2 digital inputs. Each has a range from 0 to 24 V with an impedance of 4.7
kOhm.
SIMATIC RTLS4060T
Manual, 06/2019, C79000-G8976-C550-02
freewheeling diode. A freewheeling diode D
V
is used, an additional polarity protection diode D
V
is required for higher
V
must be inserted.