EN
Quick Reference
For fast access
1.) Mechanical installation
Increase the GENIUS lock recess at the top near the power cable by approx. 15 mm.
Install cylinder in accordance with DIN 18252.
CAUTION: Metal filings at the connecting terminals of the GENIUS System may damage the internal electronics.
GENIUS systems with the convenience feature (CA/CB only) do not have openings for
door-handle rose bolts.
2.) Connections GENIUS type B
Connec-
Function
tions
A, B, C, D
Connection for the IR sensor which carries
IR signals to the GENIUS door lock switch
B, C, D, 2
Connection of KFV finger scanner
Mode switch
0, 1
Day/night mode
Operating voltage 24V DC
Terminal 2 = + positive
2, 3
Terminal 3 = – negative
External unlocking signal.
If +24 VDC is supplied to this terminal for
4
≥1 sec., then an opening cycle is perfor-
med in both operating modes
Lock status indication.
The desired state is selected by the
7
rotary switch (optional signal output max.
20mA)
5.) Rotary switch (optional signal outputs)
Terminal 7; open collector; max. load 20 mA; isolated due to coupling relay 24V (KFV accessory).
Position State
The lock is fully locked and the
1
door is closed.
1
The door is closed
1
The latch is pulled into the cylin-
der operated lock
1
A connected alarm system can be
activated or deactivated
* See GENIUS operating instructions for details on controls
KFV Karl Fliether GmbH & Co. KG - Siemensstr. 10 - 42551 Velbert - Telephone: +49 2051/278-0 - Telefax: +49 2051/278-167
GENIUS type B
3.) Operating mode:
Switch position up = day mode
Switch position down = night mode
4.) Detection of open/closed door:
Install the sensor centrally (± 1 mm) to the reed sensor.
Max. distance 4 mm (± 3 mm)
Notes
• For use in combination with alarm systems.
›
Terminal 7 is connected to negative (--) ground.
• For use in combination with doorman monitoring.
›
Terminal 7 is connected to negative (--) ground.
• For use in combination with a revolving door motor.
›
Terminal 7 is connected to negative (--) ground.
• Control with 2-channel infra-red access key*
• In order to keep the alarm system activated in the event of a po-
wer failure, the terminal is connected to negative/ground when
the alarm is deactivated.
›
Alarm deactivated = terminal 7 = negative -- relay on
›
Alarm activated = terminal 7 = high resistance -- relay off
• The relay break contact must be used to switch on the alarm
system.