C&J DGT 5000 Owners Book

Suite ‘shelf’ or ‘slab’ burner

Advertisement

C&J DGT5000
Suite 'Shelf' or 'Slab' Burner
Owner's Book
(THIS APPLIANCE IS FITTED WITH ALKALINE BATTERIES)
INCLUDES USER, INSTALLATION & MAINTENANCE
INSTRUCTIONS
Please read these instructions carefully before you start using the
appliance
Keep this booklet handy for future reference
This appliance is
for use in GREAT BRITAI or IRELA D only
A QUALITY PRODUCT FROM C&J FIRES

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DGT 5000 and is the answer not in the manual?

Questions and answers

Summary of Contents for C&J DGT 5000

  • Page 1 C&J DGT5000 Suite ‘Shelf’ or ‘Slab’ Burner Owner's Book (THIS APPLIANCE IS FITTED WITH ALKALINE BATTERIES) INCLUDES USER, INSTALLATION & MAINTENANCE INSTRUCTIONS Please read these instructions carefully before you start using the appliance Keep this booklet handy for future reference This appliance is for use in GREAT BRITAI or IRELA D only A QUALITY PRODUCT FROM C&J FIRES...
  • Page 2: Table Of Contents

    C&J DGT 5000 Instructions CONTENTS PAGE USER INSTRUCTIONS SECTION ONE Introduction Consumer Protection Health and Safety Introduction SECTION TWO Operating the appliance SECTION THREE Fuel Bed Cleaning and Layout Coal Layout Pebble Layout SECTION FOUR Important information INSTALLATION INSTRUCTIONS SECTION FIVE Specification...
  • Page 3: User Instructions

    INTRODUCTION • The C&J DGT 5000 as been designed and tested to the requirements of EN 509 and is suitable for use in GB (Great Britain) and IE (Ireland). • The C&J DGT 5000 incorporates a single gas control, which selects ignition pilot, with variable setting between low and high settings.
  • Page 4 SECTION ONE Introduction Continued The C&J DGT 5000 is battery operated; therefore no mains electrical supply is required. Power to the appliance is provided by 6 high power alkaline 1.5V batteries (AA size) (a spare set of 6 AA batteries is supplied with the appliance). Non-rechargeable high power AA Lithium type batteries (often sold for digital cameras) can give even longer service.
  • Page 5 C&J DGT 5000 Users Instructions SECTION ONE Introduction Cont. Warning:- This appliance has a naked flame, has with all fires it is recommended that a fireguard should be used for the protection of children, the elderly and infirm. Fireguards should conform to BS 6539 (1984) (fireguards for use with solid fuel appliances).
  • Page 6: Section Two Operating The Appliance

    C&J DGT 5000 Users Instructions SECTION TWO Operating the Appliance Before attempting to operate the appliance check that nothing has been placed in front of the appliance that may interfere with the remote sensor operation. To light the appliance using the remote hand set: a.
  • Page 7 C&J DGT 5000Users Instructions SECTION TWO Operating the Appliance Continued Low Battery Indication (Appliance) If you hear a double ‘bleep’ sound come from the appliance this indicates the appliance battery pack is low and should be changed as soon as possible. The appliance will continue to work normally for a short period but if the warning is ignored you may experience difficulty lighting the appliance or the appliance may automatically switch off for no apparent reason.
  • Page 8: Coal Layout

    C&J DGT 5000 Users Instructions FUEL BED LAYOUT (GRANULAR FIRE BED OPTION) • Place the black or white granular burner bed material in position in the burner tray shown. place granular materials over the top grille of the burner unit as it will drop through, block the grille,...
  • Page 9: Section Three Fuel Bed Cleaning And Layout

    C&J DGT 5000 Users Instructions SECTION THREE Fuel Bed Cleaning and Layout Cont. • Place the final row of five coals bridging between the back and front row of coals to form a final top layer as shown. DO NOT lay any further coals or pebbles on top of the burner area of the fire.
  • Page 10 C&J DGT 5000 Users Instructions SECTION THREE Fuel Bed Cleaning and Layout Cont. • Place a front row of 6 pebbles on to the front of the granular bed as shown.. • Place the final top row of 5 pebbles bridging between the first low two rows.
  • Page 11: Section Four Important Information

    Servicing It is advised that the C&J DGT 5000 fire is serviced annually this is more likely to provide trouble-free operation. A competent person must carry this out, i.e. CORGI Registered Installer in accordance with the current Gas Safety (Installation and Use) Regulations 1998 (as amended).
  • Page 12: Section Five Specification

    Use) Regulations 1998 (as amended). Failure to do so could lead to prosecution. • This C&J DGT 5000 is for use ONLY with the GAS STATED ON THE DATA BADGE this will be G20 for Natural Gas CHECK YOU HAVE THE CORRECT APPLIANCE FOR THE GAS YOU ARE USING.
  • Page 13: Section Seven Siting The Appliance

    C&J DGT 5000 Installation Instructions SECTION SIX Regulations and Warnings Continued • It can be used in conjunction with the following chimneys: - • A conventional brick or stone chimney, • A metal flue and box conforming to BS 715, further details are covered in later text.
  • Page 14: Section Eight Fireplace Requirements

    C&J DGT 5000 Installation Instructions SECTION EIGHT Fireplace Requirements INSTALLATION BASE CUTOUT (To insert outer box into) The cut out in the horizontal base of the fireplace for the outer box needs to be between 510mm and 525mm side to side and 190mm and 210mm front to back dimension. It is recommended that the base of the fireplace is no narrower than 555mm (22”) and no...
  • Page 15: Clearance To Shelf

    C&J DGT 5000 Installation Instructions SECTION EIGHT Fireplace Requirements Continued Where the fire is fitted as a “Hole in the Wall” without a hearth the installer MUST ensure the appliance is fixed firmly into the opening to ensure no movement takes place to the fuel bed when the appliance batteries are changed for example.
  • Page 16: Section Nine To Install The Appliance

    C&J DGT 5000 Installation Instructions SECTION NINE To Install the Appliance EXAMINE FLUE / CHIMNEY Check that the flue/chimney conforms to the required specifications as previously stated. Examine the condition and carry out any remedial work. If the flue/chimney has been used for solid fuel or oil, it should be swept prior to appliance installation.
  • Page 17: Installation Instructions

    C&J DGT 5000 Installation Instructions SECTION NINE To Install the Appliance Continued Form the tube so that it enters the fire via the purpose provided silicone rubber sealing membrane over the opening in the base & side of the firebox. Carefully cut ONE slit into the rubber at the most convenient point for the pipe to enter.
  • Page 18: Checking Product Clearance

    C&J DGT 5000 Installation Instructions SECTION NINE To Install the Appliance Continued • Refit pressure test point screw and check for leaks. • Refit heat shield and burner permanently ensuring that the silencer is properly in position ready to hook under the side of the burner correctly –...
  • Page 19: Maintenance Instructions

    C&J DGT 5000 Installation Instructions SECTION TEN Maintenance Instructions IMPORTANT: - REFER TO THE ‘HEALTH & SAFETY NOTICE LOCATED ON PAGE 3 OF THIS BOOKLET BEFORE CLEANING OR REPLACING ANY REFRACTORY MATERIAL. • Servicing should be carried out annually by a competent person such as a CORGI- registered person in accordance with the relevant regulations, to ensure the safe and correct operation of the appliance.
  • Page 20: Replacement Of Pilot Assembly

    C&J DGT 5000 Installation Instructions SECTION TEN Maintenance Instructions Cont. REPLACEMENT OF OXY-PILOT ASSEMBLY NOTE: If the pilot assembly is replaced it must be replaced by an identical unit from the same manufacturer and replaced as a complete unit it is a NON SERVICABLE ITEM.
  • Page 21: Warranty Cover

    For future reference we suggest you record the following details here, and keep the receipt as proof of purchase. This information may be asked for when you contact the helpdesk. Model: C&J DGT 5000 Serial No. This information can be found on the label attached to the packaging and on the data badge, which is located on a swing tab under appliance.
  • Page 22 Blank Page LT5032 (01:05-08)
  • Page 23 ________________________________ Post Code TELEPHONE No. PRODUCT DETAILS Model: C&J DGT 5000 Serial Date of Purchase This information can be found on the label attached to the packaging and on the data badge, which is located behind the appliance trim. WHERE DID YOU PURCHASE THIS PRODUCT...
  • Page 24 C&J DGT 5000 Packing NG JD Product Serial No Serial No ID Label Prefix Prefix Fire Box Labels: Spillage (Text) Data Badge Burner Tray / Box Assembly Warning Label (Fire Guard) Granules Set x 2 black & white Vermiculite bag x 1...

Table of Contents