Aircommand Kingfisher Installation, Ongoing Maintenance, Specifications, Trouble Shooting, Warranty
Aircommand Kingfisher Installation, Ongoing Maintenance, Specifications, Trouble Shooting, Warranty

Aircommand Kingfisher Installation, Ongoing Maintenance, Specifications, Trouble Shooting, Warranty

Advertisement

Quick Links

AIRCOMMAND
KINGFISHER
I
INSTALLATION
ONGOING MAINTENANCE
SPECIFICATIONS
TROUBLE SHOOTING
WARRANTY
Page 1 of 7
Revised 13/7/05
More information https://www.caravansplus.com.au

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Kingfisher and is the answer not in the manual?

Questions and answers

Summary of Contents for Aircommand Kingfisher

  • Page 1 AIRCOMMAND KINGFISHER INSTALLATION ONGOING MAINTENANCE SPECIFICATIONS TROUBLE SHOOTING WARRANTY Page 1 of 7 Revised 13/7/05 More information https://www.caravansplus.com.au...
  • Page 2 INSTALLATION INSTRUCTIONS The Aircommand Kingfisher is designed for installation beneath a benchtop or similar and is installed through the outside wall of the van. The unit requires a minimum depth of 550 mm from the outside skin of the van (refer fig.1).
  • Page 3 475mm. Ensure the inside and outside holes line up. POWER SUPPLY: Install a GPO near the front left-hand side of the unit (refer fig. 2). UNPACKING OF THE KINGFISHER: Check the following components have been supplied: Air conditioner. Facia assembly.
  • Page 4 the louvre moulding to fix it to the van. Fit caps on screws provided (see fig. 7). CHECK AGAIN THAT THE DISCHARGE DOOR HAS CLEARANCE. 5: Before installing facia, plug the unit into the GPO. A suitable clearance hole may be made to allow the plug through.
  • Page 5 ONGOING MAINTENANCE Normally the only item requiring ongoing attention is the return air filter. Aircommand recommends that the filter is inspected at least monthly and depending upon how dusty the environment, the return air filter may need to be removed, cleaned and replaced. To do this, grasp the filter with the finger grip, pull outward and upward to remove the filter assembly (see fig.
  • Page 6 UNIT SPECIFICATIONS Height: 595mm Width: 470mm Depth 500mm Weight: 52Kg Rated Voltage: 230V 50Hz Cooling output: 2.5Kw Heating Output: 2.5Kw Max. Current: 4.8Amps Locked Rotor Current: 20Amps Rated Power Input: 1150W Refrigerant: Charge 830grams Air Volume Off Evaporator 150l/s TROUBLE SHOOTING Unit will not energise Not plugged in Check plug at GPO...
  • Page 7 Should a defect due to either Faulty Material or Workmanship become apparent within the period of 12 months from date of original retail purchase of the product then Aircommand Australia will rectify such a defect, without cost to you for either labour or material, at the premises of Aircomand Australia or their Authorised Service Repairer subject to: 1.Particulars of the model and serial number,(chassis number if applicable) the date of original...