Advertisement

Quick Links

PRODUCT MANUAL: GHR-CSA
Overview
Installation & Operation
901-GR Instructions
GHR Instructions
INTERTEC
TM
INTERTEC
TM
Maintenance
Instructions
901-GR
Leading the industry in Analytically Correct™ Sampling Systems, Components, and Technology. By applying sound
principles of science and a minimalistic design approach, we manufacture our products to solve your specific sampling
needs. We specialize in Analytically Correct Sample System Design, Sample Conditioning Components, and revolutionary
gas and liquid sampling technology.
We are The Sampling Experts™.
Genie®, GHR™, are trademarks or registered trademarks of A+Corporation, LLC. All other referenced trademarks are the property of their respective
owners. © 2012 A+ Corporation. All rights reserved.
SCC-GHR-MASTER 111319
24
110
GHR
ISO 9001:2015 certified
scan for mobile
Contact us for expert product application assistance.
1.225.644.5255
|
geniefilters.com
sales@geniefilters.com
A+ Corporation
41041 Black Bayou Road
Gonzales, Louisiana 70737 United States

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Sampling Experts Genie GHR and is the answer not in the manual?

Questions and answers

Summary of Contents for A+ Corporation Sampling Experts Genie GHR

  • Page 1 A+ Corporation Genie®, GHR™, are trademarks or registered trademarks of A+Corporation, LLC. All other referenced trademarks are the property of their respective 41041 Black Bayou Road owners. © 2012 A+ Corporation. All rights reserved. Gonzales, Louisiana 70737 United States SCC-GHR-MASTER 111319...
  • Page 2: Technical Specifications

    41041 Black Bayou Road Genie®, GHR™, are trademarks or registered trademarks of A+Corporation, LLC. All other referenced trademarks are the property of their respective Gonzales, Louisiana 70737 United States owners. © 2012 A+ Corporation. All rights reserved. SCC-GHR-MASTER 111319...
  • Page 3: Product Dimensions

    OVERVIEW PRODUCT MANUAL Model Numbering & Additional Part Numbers Your model number is determined by your specific needs. Materials of construction must be compatible with process fluid. Model GHR = GR with self-limiting block heater 901-GR = GR with temperature controller Sealing material 0 = Fluoroelastomer JW = RGD resistant HNBR...
  • Page 5: Before You Start

    41041 Black Bayou Road Genie®, GHR™, are trademarks or registered trademarks of A+Corporation, LLC. All other referenced trademarks are the property of their respective Gonzales, Louisiana 70737 United States SCC-GHR-MASTER 011619 owners. © 2012 A+ Corporation. All rights reserved.
  • Page 6: Connect Tubing

    INSTALLATION AND OPERATION PRODUCT MANUAL 901-GR Installation and Operation Notes NOTICE: Do not install the regulator in an enclosure that is heated above the regulator’s maximum ambient temperature. • The regulator should be installed in a KOZY™ insulated jacket, ACES™ enclosure, or similar type of insulating device. •...
  • Page 7 INSTALLATION AND OPERATION PRODUCT MANUAL Establish flow and adjust pressure Pressure adjustment CAUTION: The regulator will be HOT. Perform the following steps with gloves on to avoid burns. screw Locking 1. Slowly open external valving to avoid a sudden surge in fluid or pressure. 2.
  • Page 8 INSTALLATION AND OPERATION PRODUCT MANUAL GHR Installation and Operation Notes • The regulator should be installed in a KOZY insulated jacket, ACES enclosure, or similar type of insulating device. • For ATEX, refer to the “Temperature Limitations” section of the enclosed INTERTEC document for information concerning the heat transfer coefficient of the enclosure surrounding the regulator.
  • Page 9 INSTALLATION AND OPERATION PRODUCT MANUAL Establish flow and adjust pressure Pressure adjustment CAUTION: The regulator will be HOT. Perform the following steps with gloves on to avoid burns. screw Locking 1. Slowly open external valving to avoid a sudden surge in fluid or pressure. 2.
  • Page 10 HEATER BLOCK INSTRUCTION AND CERTIFICATION - CSA 24 PRODUCT MANUAL www.intertec.info SL BLOCKTHERM C 24 V Self-limiting Block Heater Application The self-limiting electric conduction heater is designed to be attached directly to manifolds, measuring or analyzing instruments, control valves and similar equipment installed in hazardous areas.
  • Page 11 HEATER BLOCK INSTRUCTION AND CERTIFICATION - CSA 24 PRODUCT MANUAL www.intertec.info SL BLOCKTHERM C 24 V Self-limiting Block Heater Temperature Limitation Dimensions PTC-Elements (Positive Temperature Coefficient) raise their electric resistance with rising temperature. High resistance results in low heating power. The heating power is very low at high temperatures so that the temperature cannot exceed the maximum temperature of the respective temperature class.
  • Page 12 HEATER BLOCK INSTRUCTION AND CERTIFICATION - CSA 24 PRODUCT MANUAL www.intertec.info Operating Instructions for Heaters SL …THERM 1 Application 4 Connection The heater must only by connected and secured by …THERM Heaters manufactured accordance with Directive 94/ 9EC (ATEX 100a) and personnel technically qualified in accordance with the are approved as conduction heaters (direct heating label specifications "rated voltage"...
  • Page 13 HEATER BLOCK INSTRUCTION AND CERTIFICATION - CSA 110 PRODUCT MANUAL www.intertec.info SL BLOCKTHERM C Self-limiting Block Heater Application The self-limiting electric conduction heater is designed to be attached directly to manifolds, measuring or analyzing instruments, control valves and similar equipment installed in hazardous areas. It heats the device by conduction.
  • Page 14 HEATER BLOCK INSTRUCTION AND CERTIFICATION - CSA 110 PRODUCT MANUAL www.intertec.info SL BLOCKTHERM C Self-limiting Block Heater Temperature Limitation Dimensions PTC-Elements (Positive Temperature Coefficient) raise their electric resistance with rising temperature. High resistance results in low heating power. The heating power is very low at high temperatures so that the temperature cannot exceed the maximum temperature of the respective temperature class.
  • Page 15 HEATER BLOCK INSTRUCTION AND CERTIFICATION - CSA 110 PRODUCT MANUAL www.intertec.info Operating Instructions for Heaters SL …THERM 1 Application 4 Connection The heater must only by connected and secured by …THERM Heaters manufactured accordance with Directive 94/ 9EC (ATEX 100a) and personnel technically qualified in accordance with the are approved as conduction heaters (direct heating label specifications "rated voltage"...
  • Page 17 41041 Black Bayou Road Genie®, GHR™, are trademarks or registered trademarks of A+Corporation, LLC. All other referenced trademarks are the property of their respective Gonzales, Louisiana 70737 United States SCC-GHR-MASTER 011619 owners. © 2012 A+ Corporation. All rights reserved.
  • Page 18: Maintenance Notes

    41041 Black Bayou Road Genie®, GHR™, are trademarks or registered trademarks of A+Corporation, LLC. All other referenced trademarks are the property of their respective Gonzales, Louisiana 70737 United States SCC-GHR-MASTER 011619 owners. © 2012 A+ Corporation. All rights reserved.
  • Page 19: Inlet Filter Replacement

    MAINTENANCE PRODUCT MANUAL INLET FILTER REPLACEMENT Required Tools and Materials • Retaining ring pliers • Gloves Inlet port Discard Remove old parts Clean CAUTION: The regulator may be HOT. Allow ample time for the heater to cool prior to performing maintenance and use gloves to avoid burns.
  • Page 20 MAINTENANCE MAINTENANCE PRODUCT MANUAL Separate the two halves 1. Clamp the regulator in a vice using the wrench flats near the bottom half of the regulator body. Discard the Set the 2. Remove the bolt, nut, washer, and o-ring from the top of the o-ring rest aside regulator.
  • Page 21 MAINTENANCE PRODUCT MANUAL Replace regulator top seal #2-027 o-ring 1. Orient the regulator top so that the larger female threads are facing you. Load Spring 2. Remove the #2-027 o-ring from the cavity, discard and replace with a new o-ring. Pointed Spring side up...

This manual is also suitable for:

Sampling experts genie 901-gr

Table of Contents