CONTENTS PVR01......................................1 Remote panel for control units ACPxx............................1 CONTENTS ....................................2 INTRODUCTION ..................................3 TECHNICAL CHARACTERISTICS ............................4 ELECTRICAL CHARACTERISTICS ..........................4 MECHANICAL CHARACTERISTICS ..........................4 CLIMATIC CHARACTERISTICS............................4 DESCRIPTION OF THE PANEL.............................5 NAVIGATION CONTROLS ..............................5 KEYS FOR DATA INSERTION ............................6 CONTROLS....................................7 SIGNALLING LED'S ................................8 CONNECTIONS..................................9 EXAMPLE OF CONNECTION TO AN ACPXX CONTROL UNIT ................9...
INTRODUCTION The PVR01 is a remote control panel that can be associated with the ACPxx fire detection control units and it is used to show the information of: Fire alarm • Fire pre-alarm • Test • Fault • Out of service •...
TECHNICAL CHARACTERISTICS ELECTRICAL CHARACTERISTICS The PVR01 panel is designed to be powered directly by the ACPxx control unit or by an external power supplier. Power supply: 24 V DC • Current input: 50 mA • MECHANICAL CHARACTERISTICS Weight: 450 g...
DESCRIPTION OF THE PANEL NAVIGATION CONTROLS "Go to main menu" key: use this key to access the main menu. Function key: this key is generally inactive, its function, variable, is specified by a message that appears at the key at the bottom of the page. "Display active events"...
KEYS FOR DATA INSERTION The alphanumeric keypad is used to insert numerical data such as passwords, addresses, and so forth. If it is used to insert names, it is possible to insert capital letters, small letters or numerals. The selection of the different modes is made using the function key as shown on the display.
CONTROLS Buzzer Use this control if you want to silence the acoustic signal in the event of fault (intermittent Mute: sound), or alarm (continuous sound). Use this control to silence all the alarm sounders connected to the control unit. Silencing the sounders does not reset the alarm.
This signal flashes when a fault occurs in the RS485 communications network. Fault yellow Check the status of connections and network settings. Main power This signal is on steady when power is supplied to the PVR01 panel. supply on green PVR01_EN 24838300 22-02-10.doc Page 8 of 24...
CONNECTIONS Remove the panel to access the internal terminals. = Connect the shielding of the connection cables. + 5V = Not used. = Connect to the “-“ of the other devices of the network. = Not used. = Connect to the terminal "A" of the other network devices. = Connect to the terminal "B"...
EXAMPLES OF USE The ACPxx control units and the PVR01 panels allow good flexibility in the creation of fire prevention systems. As shown in the examples that follow, it is possible to use the panels in various kind of systems.
EXAMPLE NO. 4 n Panels n Panels n Control Units n Control Units max. 80 network max. 80 network devices devices RS485 RS485 PVR01_EN 24838300 22-02-10.doc Page 13 of 24...
OPERATIONS SCREEN AT REST Once the panel is powered, the initial window will be shown. < data > < > B R A H M S E L E T T R O N I C A P A N N E L L O x x x x x x x P R O M P T M O D I F I C A B I L E...
1. OPERATOR Once this menu is selected, the display will show: Select the function with the keys /, and then M e n u o p e r a o r e I M P O S T A Z . D A T A - O R A confirm the selection with the key Sel/Ok, or typing in 2 - V E R S I O N I...
2. MAINTENANCE Once this menu is selected, the level 2 password will be requested. The default is 2 2 2 2 2 . Insert the numbers and confirm with the key Sel/Ok, the display will show: Confirm the choice with the key Sel/Ok . To exit a M e n u m a n u t e n z...
3. INSTALLATION Once this menu is selected, the level 3 password will be requested. The default is 3 3 3 3 3 . Insert the numbers and confirm with the key Sel/Ok, the diplay will show: M e n u i n s o n e Select the function with the keys /, and then...
3.1.2. Set Filter Not all of the events that take place on a given control unit may be useful. Therefore, it is possible to use this menu to select only those events that interest you and only those zones of the system that concern you. S E L E Z .
ZONE FILTER: • It is possible to select, by pressing the key , for which zones of the control unit the events set in events filter will be shown. Beside each zone, there are brackets. If an "X" appears, the zone is active. REMOTE CONTROL: •...
3.2. EVENTS The panel can memorize up to 1000 events. M E N U E V E N T I Select the function with the keys /, and then 1 - V I S U A L I Z Z A L I S T A confirm the selection with the key Sel/Ok, or typing in 2 - S T A M P A...
3.2.3. Delete S E L E Z I O N E E V E N T I Select the desired function with the keys /, and T U T T I confirm the selection with the key Sel/Ok . To exit a D E F I N I S C I function and return to the next highest level of the tree menu, press the key Esc.
3.3. SETTINGS I M P O S T A Z I O N I Select the desired function with the keys /, and 1 - O P Z I O N I E V A C U A Z I O N E confirm the selection with the key Sel/Ok .
3.4. LOCAL NET In order to use the control panel, it is necessary to connect it to the RS485, specify that it is connected, and assign it a network address. M E N U R E T E L O C A L E Select the desired function with the keys /, and 1 - S E T T A G G I O P A R A M E T R I...
3.4.2. View Devices In order to find out which device has a given network address, use this function. V I S . D I S P O S I T I V I R E T E To exit a function and return to the next highest level of ...