Brahms PVR01 Manual

Remote panel for control units

Advertisement

Quick Links

BPT
Spa
PREVENTION
THEFT
Centro direzionale e Sede legale
Via Cornia, 1/b
FIRE
33079 Sesto al Reghena (PN) - Italia
GAS
http://www.bpt.it
mailto:info@bpt.it

PVR01

Remote panel for control units ACPxx

PVR01_EN 24838300 22-02-10.doc
Page 1 of 24

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PVR01 and is the answer not in the manual?

Questions and answers

Summary of Contents for Brahms PVR01

  • Page 1: Pvr01

    PREVENTION THEFT Centro direzionale e Sede legale Via Cornia, 1/b FIRE 33079 Sesto al Reghena (PN) - Italia http://www.bpt.it mailto:info@bpt.it PVR01 Remote panel for control units ACPxx PVR01_EN 24838300 22-02-10.doc Page 1 of 24...
  • Page 2: Table Of Contents

    CONTENTS PVR01......................................1 Remote panel for control units ACPxx............................1 CONTENTS ....................................2 INTRODUCTION ..................................3 TECHNICAL CHARACTERISTICS ............................4 ELECTRICAL CHARACTERISTICS ..........................4 MECHANICAL CHARACTERISTICS ..........................4 CLIMATIC CHARACTERISTICS............................4 DESCRIPTION OF THE PANEL.............................5 NAVIGATION CONTROLS ..............................5 KEYS FOR DATA INSERTION ............................6 CONTROLS....................................7 SIGNALLING LED'S ................................8 CONNECTIONS..................................9 EXAMPLE OF CONNECTION TO AN ACPXX CONTROL UNIT ................9...
  • Page 3: Introduction

    INTRODUCTION The PVR01 is a remote control panel that can be associated with the ACPxx fire detection control units and it is used to show the information of: Fire alarm • Fire pre-alarm • Test • Fault • Out of service •...
  • Page 4: Technical Characteristics

    TECHNICAL CHARACTERISTICS ELECTRICAL CHARACTERISTICS The PVR01 panel is designed to be powered directly by the ACPxx control unit or by an external power supplier. Power supply: 24 V DC • Current input: 50 mA • MECHANICAL CHARACTERISTICS Weight: 450 g...
  • Page 5: Description Of The Panel

    DESCRIPTION OF THE PANEL NAVIGATION CONTROLS "Go to main menu" key: use this key to access the main menu. Function key: this key is generally inactive, its function, variable, is specified by a message that appears at the key at the bottom of the page. "Display active events"...
  • Page 6: Keys For Data Insertion

    KEYS FOR DATA INSERTION The alphanumeric keypad is used to insert numerical data such as passwords, addresses, and so forth. If it is used to insert names, it is possible to insert capital letters, small letters or numerals. The selection of the different modes is made using the function key as shown on the display.
  • Page 7: Controls

    CONTROLS Buzzer Use this control if you want to silence the acoustic signal in the event of fault (intermittent Mute: sound), or alarm (continuous sound). Use this control to silence all the alarm sounders connected to the control unit. Silencing the sounders does not reset the alarm.
  • Page 8: Signalling Led's

    This signal flashes when a fault occurs in the RS485 communications network. Fault yellow Check the status of connections and network settings. Main power This signal is on steady when power is supplied to the PVR01 panel. supply on green PVR01_EN 24838300 22-02-10.doc Page 8 of 24...
  • Page 9: Connections

    CONNECTIONS Remove the panel to access the internal terminals. = Connect the shielding of the connection cables. + 5V = Not used. = Connect to the “-“ of the other devices of the network. = Not used. = Connect to the terminal "A" of the other network devices. = Connect to the terminal "B"...
  • Page 10: Examples Of Use

    EXAMPLES OF USE The ACPxx control units and the PVR01 panels allow good flexibility in the creation of fire prevention systems. As shown in the examples that follow, it is possible to use the panels in various kind of systems.
  • Page 11: Example No. 2

    EXAMPLE NO. 2 n Panels (max. n Panels (max. 1 Control Unit 1 Control Unit RS485 RS485 PVR01_EN 24838300 22-02-10.doc Page 11 of 24...
  • Page 12: Example No. 3

    EXAMPLE NO. 3 1 Panel 1 Panel n Control Units (max n Control Units (max RS485 RS485 PVR01_EN 24838300 22-02-10.doc Page 12 of 24...
  • Page 13: Example No. 4

    EXAMPLE NO. 4 n Panels n Panels n Control Units n Control Units max. 80 network max. 80 network devices devices RS485 RS485 PVR01_EN 24838300 22-02-10.doc Page 13 of 24...
  • Page 14: Operations

    OPERATIONS SCREEN AT REST Once the panel is powered, the initial window will be shown. < data > < > B R A H M S E L E T T R O N I C A P A N N E L L O x x x x x x x P R O M P T M O D I F I C A B I L E...
  • Page 15: Operator

    1. OPERATOR Once this menu is selected, the display will show: Select the function with the keys /, and then M e n u o p e r a o r e I M P O S T A Z . D A T A - O R A confirm the selection with the key Sel/Ok, or typing in 2 - V E R S I O N I...
  • Page 16: Maintenance

    2. MAINTENANCE Once this menu is selected, the level 2 password will be requested. The default is 2 2 2 2 2 . Insert the numbers and confirm with the key Sel/Ok, the display will show: Confirm the choice with the key Sel/Ok . To exit a M e n u m a n u t e n z...
  • Page 17: Installation

    3. INSTALLATION Once this menu is selected, the level 3 password will be requested. The default is 3 3 3 3 3 . Insert the numbers and confirm with the key Sel/Ok, the diplay will show: M e n u i n s o n e Select the function with the keys /, and then...
  • Page 18: Set Filter

    3.1.2. Set Filter Not all of the events that take place on a given control unit may be useful. Therefore, it is possible to use this menu to select only those events that interest you and only those zones of the system that concern you. S E L E Z .
  • Page 19: Remove

    ZONE FILTER: • It is possible to select, by pressing the key  , for which zones of the control unit the events set in events filter will be shown. Beside each zone, there are brackets. If an "X" appears, the zone is active. REMOTE CONTROL: •...
  • Page 20: Events

    3.2. EVENTS The panel can memorize up to 1000 events. M E N U E V E N T I Select the function with the keys /, and then 1 - V I S U A L I Z Z A L I S T A confirm the selection with the key Sel/Ok, or typing in 2 - S T A M P A...
  • Page 21: Delete

    3.2.3. Delete S E L E Z I O N E E V E N T I Select the desired function with the keys /, and  T U T T I confirm the selection with the key Sel/Ok . To exit a D E F I N I S C I function and return to the next highest level of the tree menu, press the key Esc.
  • Page 22: Settings

    3.3. SETTINGS I M P O S T A Z I O N I Select the desired function with the keys /, and 1 - O P Z I O N I E V A C U A Z I O N E confirm the selection with the key Sel/Ok .
  • Page 23: Local Net

    3.4. LOCAL NET In order to use the control panel, it is necessary to connect it to the RS485, specify that it is connected, and assign it a network address. M E N U R E T E L O C A L E Select the desired function with the keys /, and 1 - S E T T A G G I O P A R A M E T R I...
  • Page 24: View Devices

    3.4.2. View Devices In order to find out which device has a given network address, use this function. V I S . D I S P O S I T I V I R E T E To exit a function and return to the next highest level of ...

Table of Contents