VDH FC 3500 DC User Manual

VDH FC 3500 DC User Manual

Fan control, frequency control

Advertisement

Description:
FC 3500 DC
Type:
Manual
File:
Do150304 FC 3500 DC V12 EN.docx
VDH Products BV
Manual FC 3500 DC
Fan Control
Pages:
By:
Initials:
23
Doc.no:
BVDB
Version:
Date:
150304
1.2
15-04-2015

Advertisement

Table of Contents
loading

Summary of Contents for VDH FC 3500 DC

  • Page 1 Manual FC 3500 DC Fan Control Description: FC 3500 DC Pages: Doc.no: 150304 Type: Manual BVDB Version: File: Do150304 FC 3500 DC V12 EN.docx Initials: Date: 15-04-2015 VDH Products BV...
  • Page 2: Table Of Contents

    Trouble shooting ............................. 18 Installation ................................. 19 Connection FC 3500 DC drawing 150182w0 ................... 19 Block diagram FC 3500 DC drawing 150201w1 ................20 Dimensions FC 3500 DC ........................21 Appendix-A: FC 3500 BP display panel ....................... 22 Page 2 of 23...
  • Page 3: Introduction

    FC 3500 DC Fan Control Document no.:150304 Version: 1.2 1 Introduction This document describes the working and control of the Heinen & Hopman FC 3500 DC. The system can consist of the following parts: 1) FC 3500 DC: Main Panel...
  • Page 4: Warning

    However VDH Products BV accepts no liability for any mistakes or errors. Copyright Notice Copyright 2015 VDH Products BV, Roden The Netherlands. No part of this document may be reproduced without the prior written permission of VDH Products BV. Edition v1.0 1st pre-release edition 31-03-2015...
  • Page 5: Safety Instructions

    2.1 Electric Shock Prevention WARNING · While power is on or when the FC 3500 DC is running, do not open the top cover of the housing. You may get an electric shock. · Do not run the FC 3500 DC with the top-cover removed. Otherwise, you may access the exposed high-voltage parts and get an electric shock.
  • Page 6: Additional Instructions

    Any person who is involved in the wiring or inspection of this equipment should be fully competent to do the work. · Check if the nominal supply voltage from the FC 3500 DC is equal to the AC-supply voltage. A incorrect power supply voltage can lead to fire, injury or failure. ·...
  • Page 7 Before running a FC 3500 DC which had been stored for a long period, always perform inspection and test operation. · For a good performance the FC 3500 DC must be installed in a room which is not applied to extreme temperature changes. ·...
  • Page 8 Do not carry out a megger (insulation resistance) test on the control circuit of the FC 3500 DC. · Replace parts only when the FC 3500 DC is switched off, wait 10 minutes and then open up the unit to replace the needed part. Disposing of the unit CAUTION ·...
  • Page 9: Technical Data

    FC 3500 DC Fan Control Document no.:150304 Version: 1.2 3 Technical Data FC 3500 DC Description Comment Power supply voltage 90Vac .. 260Vac, 50/60Hz Supply (L, N, PE) Power consumption 34,5 VA On/Off switch before 1,5mm2 (14 AWG) flexible or FC 3500 DC solid wirring stripped 9mm.
  • Page 10: Installation

    Version: 1.2 4 Installation This manual is written for the FC 3500 DC controller unit. Incorrect handling may cause the FC 3500 DC to operate incorrectly, causing its life to be reduced considerably, or at the worst, the FC 3500 DC to be damaged.
  • Page 11: Control

    Version: 1.2 5 Control To control the FC 3500 DC fan control, a display-unit should be connected to it. Standard is the FC 3500 BP (4 button display-unit, see appendix A) connected at the RS485 Network connection of the controller.
  • Page 12: Adjusting The Fan Speed

    FC 3500 DC Fan Control Document no.:150304 Version: 1.2 5.3 Adjusting the fan speed Press the FAN key to view the fan speed setting. The LED FAN will lit. Select with the RAISE or LOWER key the fan speed. (NB. It may not always be possible to lower the fan speed due to requirements for heating or boosting.
  • Page 13: Programming Parameters

    FC 3500 DC Fan Control Document no.:150304 Version: 1.2 6 Programming Parameters To access the parameter mode; · Switch the unit off with the ON/OFF key. · Press the LOWER key for more than 10 seconds. · You are asked to enter an access code.
  • Page 14: Parameter Table

    FC 3500 DC Fan Control Document no.:150304 Version: 1.2 6.1 Parameter table Number Description Range Unit Default Sensors P 10 Offset room sensor -10 .. 10°K °K/°F 0°K -18..18°F 0°F P 11 Offset water sensor -10 .. 10°K °K/°F 0°K -18..18°F...
  • Page 15 FC 3500 DC Fan Control Document no.:150304 Version: 1.2 Number Description Range Unit Default Humidity control Humidity control 0 .. 2 0 = None 1 = Readout only 2 = Readout and control Humidity set point 0 .. 100% Differential humidity while heating 1 ..
  • Page 16 FC 3500 DC Fan Control Document no.:150304 Version: 1.2 Number Description Range Unit Default Voltage output settings Voltage output at 0% auto-fan speed 12 .. 100 Voltage output at 100% auto-fan 12 .. 100 100% speed Water valve settings Pulse pause cycle time (water valve) 0 ..
  • Page 17 FC 3500 DC Fan Control Document no.:150304 Version: 1.2 Number Description Range Unit Default 3 = Fan with rpm Fan 3 speed 1 12 .. 100 Fan 3 speed 2 12 .. 100 Fan 3 speed 3 12 .. 100 Fan 3 speed 4 12 ..
  • Page 18: Night Temperature Offset (P70)

    FC 3500 DC Fan Control Document no.:150304 Version: 1.2 Additional explanation of parameter: 6.2 Night temperature offset (P70) During nighttime it is possible to give the set point an offset of parameter P70 (-10..10°K/- 18..18°F) degrees, which lowers the normal set point. F.i.: Set point at 20°C, and P70=+5°K gives at nighttime a set point of (20°C - (+5°K) )= 15°C or...
  • Page 19: Installation

    FC 3500 DC Fan Control Document no.:150304 Version: 1.2 8 Installation Installation drawings 8.1 Connection FC 3500 DC drawing 150182w0 Page 19 of 23...
  • Page 20: Block Diagram Fc 3500 Dc Drawing 150201W1

    FC 3500 DC Fan Control Document no.:150304 Version: 1.2 8.2 Block diagram FC 3500 DC drawing 150201w1 Page 20 of 23...
  • Page 21: Dimensions Fc 3500 Dc

    FC 3500 DC Fan Control Document no.:150304 Version: 1.2 8.3 Dimensions FC 3500 DC Page 21 of 23...
  • Page 22: Appendix-A: Fc 3500 Bp Display Panel

    FC 3500 DC Fan Control Document no.:150304 Version: 1.2 Appendix-A: FC 3500 BP display panel A1 Frontview FC 3500 BP drawing number 150233w0 A2 Dimensions FC 3500 BP Attention: There may be more types of FC 3500 BP display units which may have different...
  • Page 23 FC 3500 DC Fan Control Document no.:150304 Version: 1.2 A3 Connections FC 3500 BP Page 23 of 23...

Table of Contents