Telular PHONECELL SX3e AMPS User Manual

Fixed wireless terminal

Advertisement

Quick Links

HONECELL ®
P
F
IXED
Total communications freedom at your
fingertips...voice/fax/data.
06/25/01
W
IRELESS
U
M
S E R
SX3e AMPS
T
ERMINAL
ANUAL
Part No. 56017302

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PHONECELL SX3e AMPS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Telular PHONECELL SX3e AMPS

  • Page 1 HONECELL ® IXED Total communications freedom at your fingertips...voice/fax/data. 06/25/01 SX3e AMPS IRELESS S E R ANUAL ERMINAL Part No. 56017302...
  • Page 2: Introduction

    Battery Back-Up (optional) Thank you for choosing the Phonecell SX3 Fixed Wireless Terminal from Telular. This innovative product lets you connect up to five pieces of standard telephone equipment into a cellular network for total communications flexibility. Please follow this guide to unpack, set up and operate your new Phonecell safely and properly.
  • Page 3: Table Of Contents

    Introduction...2 Technical Support ...2 Getting Started Unpacking the Phonecell SX3e...4 Pre-Installation Checklist ...4 Installation Summary ...5 Step 1. Choose an Antenna Location...6 How to Connect the Antenna ...7 Step 2. Plug in Your Telephone ...8 Connect Your Telephone ...8 Place a Call – Adjust Your FWT ...8 Adding More Phones ...8...
  • Page 4: Getting Started

    Carefully remove the unit from the shipping carton and check for evidence of shipping damage. If damage is found, contact your Authorized Telular Distributor or shipping agent immediately. Pre-Installation Checklist Before attempting Phonecell SX3e installation, make sure you have the following components, tools and materials. Components Needed Qty.
  • Page 5: Installation Summary

    There are four steps to installing the Phonecell SX3e FWT properly. These steps are summarized below and explained in detail in the remainder of this manual. Step 1. Choose an Antenna Location (pg. 6-7) Choose a location. Next, connect power to the FWT and turn the unit ON.
  • Page 6: Step 1. Choose An Antenna Location

    Never splice antenna cable. Fig. 2 Optional high-gain antenna installed on the building’s exterior. Always direct the antenna toward the nearest cell tower of your service provider. SX3e AMPS HONECELL Fig. 1 pointed upward and located near the window for optimum signal strength.
  • Page 7: How To Connect The Antenna

    (GREEN) signal, you’re ready for the next step – connecting a phone and making a call. WARNING! Never operate your Phonecell when any person is within 16 inches (40 cm) of the antenna. SX3e AMPS HONECELL Fig. 3 Optional Power Supply AC Line Cord...
  • Page 8: Step 2. Plug In Your Telephone

    (RJ-11) phone cord. 2) Connect the other end of the cord to the RJ-11 port on the back of your Phonecell SX3e – see Fig. 6. Place a Call – Adjust Your FWT: 1) Pick up the phone receiver and listen for dial tone.
  • Page 9: Step 3. Nam/Phone Number Setup

    If you need to override any of the settings, continue with the following steps (#5–8). Otherwise, hang up. The flashing LED indicator will become solid GREEN. Phone number setup is complete. SX3e AMPS HONECELL IMPORTANT! 1 2 3 4 4 3 2 1 #...
  • Page 10 0 to 1023. (For example, to set up channel 566, enter #*25*566#.) If you enter the channel incorrectly, you'll hear three short tones followed by the programming tone; if correct, you'll hear the programming tone again. SX3e AMPS HONECELL _ _ _ _ # _ _ _ _ #...
  • Page 11: Optional A-Key (Authentication Code) Setup

    SX3i will not update or store this; the currently stored value will remain. For security reasons, your complete A-Key is never transmitted over the phone. However, you should keep the number in a safe place to prevent counterfeiting, fraud or cloning. SX3e AMPS HONECELL _ _ # 0 for System “A” preferred 1 for System “B”...
  • Page 12: Step 4. Install Your Phonecell

    Then, mount the Phonecell onto the screws and slide it down- ward until the screw heads lock into the bracket and the unit is secure–see Figure 12. SX3e AMPS HONECELL -inch Fig. 12 Fig. 8 Fig. 9 Fig.
  • Page 13: Desktop/Tabletop Installation

    Your Phonecell SX3 must be placed or mounted on a flat, level surface to allow proper ventilation. Do not block the air vents or the space beneath your Phonecell as this could cause the unit to overheat and fail. SX3e AMPS HONECELL Phonecell Installation – Continued IMPORTANT! Fig.
  • Page 14: Phonecell Sx3E Operation

    Depending upon your phone, there are two ways to initiate the Hookflash function: Press the dedicated “HOOKFLASH” or “FLASH” key on your telephone. Press the hang-up or switch-hook mechanism on your phone once quickly (approximately -second). SX3e AMPS HONECELL LED Indicator Description Malfunction. Hardware fault detected...
  • Page 15: Important Tones And Alerts

    Depending upon the type of modem used and the cellular network’s capability, data transmis- sion rates of 2400 baud and higher are normally possible. SX3e AMPS HONECELL Phonecell Operation – Continued 8 until the desired level is reached. Down) 3 until the desired level is reached.
  • Page 16: Variable Dial Time (Auto Send Delay) Option

    Call Waiting – If your cellular provider requires codes to be entered involving dig- its 1-9, *, and # to answer a waiting call, the Out-of-Band Signaling option must be enabled. See the Data After SEND option on page 17. SX3e AMPS HONECELL <Auto SEND Delay> #...
  • Page 17: Data After Send (In-Call Dtmf Signaling) Option

    NOTE: cycling (turning ON/OFF) the power will erase the current list. A new list will be started when power is re-applied. To enable or disable this feature, see page 24. SX3e AMPS HONECELL Phonecell Operation – Continued <in-call DTMF option>...
  • Page 18: Phonecell Sx3E Troubleshooting

    If the telephone system or wiring is not working properly, replace or repair the equipment as required. Otherwise, contact your cellular provider or your authorized Telular distributor. Unable to Receive Incoming Calls If more than one telephone or telephone device is connected to your Phonecell, make sure that all devices are “on-hook”...
  • Page 19: Important Safety Information

    Standard. In March, 1993, the U.S. Federal Communications Commission (FCC) proposed the adoption of this updated Standard. The design of your Telular Phonecell SX3 FWT complies with this updated Standard. Of course, if you want to limit RF exposure even further than the updat- ed ANSI Standard, you may choose to control the duration of your calls and oper- ate your phone in the most power-efficient manner.
  • Page 20 Safety Information – Continued Driving Check the laws and regulations on the use of cellular products in the areas where you drive. Some jurisdictions prohibit your using a cellular device while driving a vehicle. Even if your jurisdiction does not have such a law, we strongly suggest that, for safety reasons, the driver use extreme caution when operating the cellular device while the vehicle is in motion.
  • Page 21 Increase the separation between the equipment and the terminal. Connect the equipment into an outlet on a circuit different from that to which the terminal is connected. Consult your Authorized Telular Distributor or an experienced radio/TV techni- cian for help. SX3e AMPS HONECELL Safety Information –...
  • Page 22: Amps Technician Programming

    Phonecell, violate local regulations and breach the service agree- ment with the cellular provider. For further assistance, please contact your Authorized Telular Representative. AMPS Technician Programming Commands The Phonecell SX3 can be programmed on location with an ordinary telephone, which is sometimes referred to as a POTS (Plain Old Telephone Set) phone.
  • Page 23: How To Set The Access Overload Class (Accolc)

    You must enter either 0 or 1, otherwise the FWT will not update or store this value; the existing stored parameter will remain. The factory default setting is 1. SX3e AMPS HONECELL < ACCOLC > # <EX option> #...
  • Page 24: How To Set The Post-Receiver Off-Hook (Roh) Option

    You must enter either 0 or 1, otherwise the FWT will not update or store this value; the existing stored parameter will remain. The factory default setting is 1. SX3e AMPS HONECELL <Post-ROH option> # 0 for continuous ROH tone 1 to turn off ROH tone and periodically check for an on-hook condition.
  • Page 25 The self test interval is programmed in 1 minute intervals from 1 to 65,535. A value of 0 disables the self test. If the value is not between 9 and 65,535 it will be considered invalid. The factory default setting is 180. SX3e AMPS HONECELL ANUAL...
  • Page 26 Part No. 56017302 ©2001 Telular Corporation...

Table of Contents