EAGLE 1
H
S Gas Detector Watch
2
Operating Instructions
Revision: 3
Approval by
Checked by
Originated by
OV
JH
OV
Rue du Marché 7 - P.O. Box 27 - 2520 La Neuveville - Switzerland - T. +41.32.751.29.64 - F. + 41.32.751.29.35 - info@northeagles.ch

Advertisement

Table of Contents
loading

Summary of Contents for NORTH EAGLES Eagle 1

  • Page 1 EAGLE 1 S Gas Detector Watch Operating Instructions Revision: 3 Approval by Checked by Originated by Rue du Marché 7 - P.O. Box 27 - 2520 La Neuveville - Switzerland - T. +41.32.751.29.64 - F. + 41.32.751.29.35 - info@northeagles.ch...
  • Page 2: Versions

    Versions Revision Date Editor Modifications 31.07.2018 OV Initial release 22.03.2018 OV US certification additions 07.08.2018 OV FCC certification additions Referenced Document Description File name [1] mode emploi V3 Mode d'emploi-v03.pdf Rue du Marché 7 - P.O. Box 27 - 2520 La Neuveville - Switzerland - T. +41.32.751.29.64 - F. + 41.32.751.29.35 - info@northeagles.ch...
  • Page 3: Table Of Contents

    Table of contents Versions ..................................2 Referenced Document ..............................2 Table of contents ................................3 Introduction ................................4 Safety Warning To Read Before Any Operating Of The Watch ................5 Security Warning To Read Before Any Operating Of The Watch................ 5 FCC Statement ..............................
  • Page 4: Introduction

    Introduction The NORTH EAGLES gas detecting watch “Eagle 1” is a single gas detection instrument manufactured by NORTH EAGLES in Switzerland. The watch permanently measures the concentration of H2s gas in the ambient air and triggers an alarm once the pre-set gas levels on the watch are exceeded.
  • Page 5: Safety Warning To Read Before Any Operating Of The Watch

    Safety Warning To Read Before Any Operating Of The Watch 1. Never replace the sensor, the battery or any other components by any person other than certified North Eagles technicians. 2. Never change the battery in a ATEX zone. 3. Regularly test the reaction of the watch by exposing the watch to a gas concentration superior to the low gas alarm setting.
  • Page 6: Ic Statement

    AGENT & IMPORTER FOR USA: CH MARKETING LLC P.O.Box 170 Peapack – NJ 07977 Phone: 201 924 02 66 IC Statement This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
  • Page 7: Factory Settings

    Factory Settings Both hands and the disc are set at the factory. The day time is set to Swiss time (GMT+1). The watch is delivered in SLEEP mode, the gas sensor is not activated, the hands a set at 9 0’clock and the disc is set on SENSOR 6.1.
  • Page 8: Setting The Time

    Setting The Time 7.1. Setting The Minutes And Hour Time Using the TIME mode, press simultaneously both pushers until you hear a beep. This beep sound indicates that the watch is in hours SETTING and the disc indicates DETECT Press the EXP pusher to increment hours. Press the EXP pusher to decrement hours.
  • Page 9: Alarm

    Alarm The watch is continuously measuring the presence of gas in the ambient air. In case of gas detection, the watch automatically reverts to code «ALARM Once gas is no longer detected, the watch reverts to TIME mode 8.1. Alarm Mode In ALARM mode, the disc indicates DETECT .
  • Page 10: Twa And Exposed Duration

    TWA and Exposed Duration When the watch is exposed to gas, both following values can be read: - TWA (Time Weighted Average), is the average time of exposure to gas on 8 hours. - Maximum exposition, this is the maximum level of gas concentration measured. It is possible to view the TWA and Maximum exposition when the watch is not exposed to gas.
  • Page 11: Eol (Eol=End Of Life)

    (EOL=End Of Life) It is possible to read the following two values: - EOL SENSOR, indicator of sensor caption (time before re-calibrating). - EOL BATTERY, battery end of life indicator. The sensor must be re-calibrated frequently. This period of time is configurable only with the technical application (the default value is 2 years) Checking EOL SENSOR and EOL Battery is only possible when the watch is not exposed to gas.
  • Page 12: Battery Discharged

    10.6. Battery Discharged When the battery is discharged (<5%) the watch does no longer display the time of day, and the disc will display BATT and the hour hand will indicate the lowest point on the scale marked REPLACE on the dial. 10.7.
  • Page 13: Calibration

    Calibration When the watch is subjected to a significant shock, it is possible that the disc or the hands lose their alignment. Also, during a battery change, it is necessary to re-calibrate the disc and hands. 11.1. Calibration Of The Hands And Disc From the «TIME »...
  • Page 14: Sleep Mode

    Sleep mode The sleep mode purpose is to avoid battery discharge. When in this mode, the gas detection is disactivated. The hands are resting at 9 o’clock and the disc is resting on SENSOR. The watch will keep the time but will not display it anymore The sleep mode can be only activated by an authorized service centre.
  • Page 15: Specifications

    Specifications 13.1. Norms and certifications The NORTH EALGES gas detector watch meets and complies with the following norms : EN 60079-0 :2012+A11 :2013 IEC 60079-0 Ed. 6.0 EN 60079-11 :2012 IEC 60079-11 Ed. 6.0 UL 61010-1 :2012/CSA C22.2No. 61010-1-12 UL 60079-0 Part0 : 6 edition UL 60079-11 Part 11 : 6 edition...
  • Page 16 13.5. Dimensions and mass of the product Case dimensions: 62 x 41 x 25 mm / 2.44 x 1.61 x 0.98 in Strap (long part) dimensions: 136 x 26 x 4 mm / 5.35 x 1.02 x 0.15 in Strap (short part) dimensions: 87 x 26 x 4 mm / 3.42 x 1.02 x 0.15 in Total mass: 115 gr / 4,05 oz 13.6.