  • Page 1 OPERATING MANUAL SESAM 800 RX, RXD and RX DIN 942858-000 EN -C1...
  • Page 2: Table Of Contents

    2 (28) Table of Contents Introduction ______________________________________________ 3 Scope ___________________________________________________ 3 Service __________________________________________________ 3 Maintenance ______________________________________________ 3 Technical Specifications ____________________________________ 4 Description of the System __________________________________ 5 Receivers _________________________________________________ 5 Transmitter ________________________________________________ 6 Description of the Receivers _________________________________ 6 Installation of the Receiver __________________________________ 9 Placement of the Receiver ____________________________________ 9 Antenna Placement ________________________________________ 10 Connections on the Receiver (all models) _______________________ 10...
  • Page 3: Introduction

    Introduction 3 (28) Introduction This manual only covers the installation of the Sesam radio remote door opening system. The Sesam System is not a complete door opening system: it provides only the set of outputs that are driven according to the actions performed by the operator of the transmitter.
  • Page 4: Technical Specifications

    Technical Specifications 4 (28) Technical Specifications Table 1. Technical Specifications, Sesam 800 L99 RX RXD System Specifications Operating frequency: 869,8 MHz Channel separation: 25 kHz Power output: < 5 mW Functional sensitivity: <= -107 dBm BER 10 Transmission principle: GMSK, TDMA, Operating Temperature: -25°C - +55°C Storage Temperature: -40°C - +85°C...
  • Page 5: Description Of The System

    Description of the System 5 (28) L99 Specifications IP- class: IP67 Dimensions: 120x75x30 Weight: 200g Battery type: 2 * AA Alkaline Screw Size: Description of the System Receivers This document covers three receiver models; RX, RXD and RX DIN. RX and RXD can be ordered as 230 VAC or 12-24 VAC/DC. RX DIN can be ordered only as 12-24 VAC/DC.
  • Page 6: Transmitter

    Description of the Receivers 6 (28) Transmitter This document covers the Sesam 800 L99 transmitter. Important features are: • A transmitter suitable for controlling up to 1000 different doors. • Integrated back lighted display • Optional cassette with external power and antenna connectors Type label position Description of the Receivers...
  • Page 7 Description of the Receivers 7 (28) Figure 2. Sesam 800 RX 12-24 V DC model indicators, connections and jumper. 1. LED 1 Relay 1 status 2. LED 2 Relay 2 status 3. LED 3 Relay 3 status 4. LED 4 Power LED 5.
  • Page 8 Description of the Receivers 8 (28) Figure 4. Sesam 800 RXD 230 V AC model connections  1. Power connection, 2. Connection to relay 1, ARROW UP 3. Connection to relay 2, STOP 4. Connection to relay 3, ARROW DOWN 5.
  • Page 9: Installation Of The Receiver

    Installation of the Receiver 9 (28) Installation of the Receiver The permanent installation of the receiver must include fuses that protect the equipment and wiring from overcurrent and short-circuit. In detail the power supply of the receiver and all relay contacts must be fused. All fuses are used as disconnecting devices.
  • Page 10: Antenna Placement

    Installation of the Receiver 10 (28) Antenna Placement Attach the supplied antenna to the antenna connector on the receiver. Note that the antenna must not be placed near metal objects such as wiring, tin roof, etc. If an antenna cable is needed, contact Åkerströms Björbo AB. Connections on the Receiver (all models) The receiver is equipped with connections for relays;...
  • Page 11: Indicators On The Receivers

    Indicators on the Receivers 11 (28) Indicators on the Receivers Sesam 800 RX The Sesam 800 RX model has seven LED indicators that are displaying system information (see fig. 1 for positions of the LEDs). The indications on the LEDs are as follows: LED 1 Relay 1 status: LED ON indicates that the relay is active.
  • Page 12: Sesam 800 Rx Din

    Configuration of the Receiver 12 (28) Sesam 800 RX DIN The Sesam 800 RX DIN model has three LED indicators that are displaying system information (see fig. 6 for positions of the LEDs). The indications on the LEDs are as follows: LED 5 Squelch: Indicates a detected signal on the operating frequency band.
  • Page 13: Sesam 800 Rx Din

    Configuration of the Receiver 13 (28) 10.2 Sesam 800 RX DIN 10.2.1 Basic Configuration Choose the door number that shall be used (0-999) and enter the number on the transmitter. Press the Learn/Erase button on the receiver until LED 7 is ON. The Learn Mode will be active for 10 seconds (as long as LED 7 is ON).
  • Page 14 Configuration of the Receiver 14 (28) 10.3.2 Advanced Configuration This configuration allows the user to choose at what memory position a certain transmitter shall be stored in. Adding a transmitter in a certain memory position Press the “Learn/Erase” button. The display window shall show “L r n” followed by the memory posi- tion that the transmitter will be stored in.
  • Page 15 Configuration of the Receiver 15 (28) 10.3.4 Re- configuring a Transmitter in the Receiver SESAM 800 RXD If the user attempts to program a transmitter that is already programmed in the receiver, the display will show “E r r 1” followed by the original memory position on the display. Erase the original memory position before proceeding with the configuration.
  • Page 16 Configuration of the Receiver 16 (28) To unlock the receiver do the following: Press the Enter button and hold it down for 5 seconds. The display should now show “Pin” followed by “_ _ _”. If the user is inactive for more than 10 seconds in the PIN configuration mode the receiver will return to nor- mal operations.
  • Page 17: High Security Transmission Mode

    Configuration of the Receiver 17 (28) 10.4 High Security Transmission Mode The High Security Transmission Mode uses encrypted authentication to ensure that the receiver only replies to commands from transmitters stored in the mem- ory. This mode makes it difficult to scan and record messages that could, with the right technology, open doors without using an authentic coded transmitter.
  • Page 18 Configuration of the Receiver 18 (28) 10.5.1 Copying Information from a Memory Card to a New Receiver Turn the power off the receiver. Unscrew the 6 screws holding the receiver lid. Carefully remove the display card. Insert the memory card that you want to copy in the memory card slot in the receiver (see fig.
  • Page 19: Description Of The Sesam 800 L99

    Description of the Sesam 800 L99 19 (28) 1. Memory card slot 2. Display slot Figure 10. Memory card and display slots in the receiver Description of the Sesam 800 L99  1. Indicator LED. 2. Display 3. Function buttons (from left to right ARROW UP, STOP, ARROW DOWN) 4.
  • Page 20: Indications On The Transmitter

    Using the System 20 (28) 11.1 Indications on the Transmitter 11.1.1 LED Indicator Normal operation Quick flashing RED = sending message. Continuous GREEN = Relay activated in the receiver (Feedback information from receiver). Battery warning 3 long RED flashes = Battery depleted, transmitter cannot send commands. Continuous RED after activating command = Low battery.
  • Page 21: Configuration Of The Transmitter

    Configuration of the Transmitter 21 (28) Configuration of the Transmitter 13.1 Group ID All Sesam 800 transmitters have a factory pre-programmed unique identity (ID). This is a number between 1000000 and 16777214. In addition to the pre-programmed unique ID, the Sesam L99 has support for Group ID.
  • Page 22: Display Window Illumination

    Configuration of the Transmitter 22 (28) 13.2 Display Window Illumination The display on the Sesam L99 has built in automatic illumination that can be ON or OFF. Typically, the battery life will increase by turning the illumination OFF. 13.2.1 Configuration of the Display Window Illumination Remove the back side of the transmitter (see fig. 15). Remove one battery.
  • Page 23: Installation Of Holder

    Installation of Holder 23 (28) Installation of Holder Holder with power supply and antenna (943015-000). Holder (943015-003). 14.1 Mounting and Attach Holder, Front Mounted Back Figure 12. Mounting holder For holder the screws on the back have to be screwed (see fig. 12). For all holders the ball has to be attached with a screw on the front and a nut on the back (see fig.
  • Page 24: Installation Of Power Supply To The Holder

    Installation of Holder 24 (28) 14.2 Installation of Power Supply to the Holder, Connect the holder to 12/24 V DC where the brown cable is connected to (+) and the blue cable to ground (-). If the cable is connected wrong a fuse inside the holder will blow. This fuse can be ordered from Åkerströms Björbo AB, art.nr 943696-000.
  • Page 25: Replacing Batteries In The Transmitter

    Replacing Batteries in the Transmitter 25 (28) Replacing Batteries in the Transmitter If the display on the transmitter indicates “L O b A T”, replace the batteries promptly. Note that changing of batteries must take place in a clean environment free from static electricity. The batteries are changed as follows: Open the battery cover by unscrewing the 6 screws on the backside of the transmitter housing (see fig.
  • Page 26: Error Codes

    Error Codes 26 (28) Error Codes The Sesam 800 receivers can display some error codes. The error code depends on the model of the receiver. Error codes, Sesam 800 RXD Table 2. Error codes Sesam 800 RXD ID already programmed Memory full Memory card mismatch during power up Memory card write error.
  • Page 27: Receiver Drill Measure For Rx And Rxd

    Receiver Drill Measure for RX and RXD 27 (28) Receiver Drill Measure for RX and RXD 225 mm 120 mm 102 mm Figure 18. Receiver Drill Measure for RX and RXD The receiver shall be attached with 4 mm screws that are suitable for the sur- rounding environment 17.1 Measure for RX DIN...
  • Page 28 Åkerströms Björbo AB Box 7, SE-785 21 Gagnef, Sweden street Björbovägen 143 SE-786 97 Björbo, Sweden Phone +46 241 250 00 Fax +46 241 232 99 E-mail sales@akerstroms.com www.akerstroms.com © Åkerströms Björbo AB, 2013...

This manual is also suitable for:

Sesam 800 l99 rxSesam 800 l99 rxdSesam 800 l99 rx din

Table of Contents