Flepcher FLP-ZS9812 MKII Operation Manual

Public address system, zone selector

Advertisement

Quick Links

FLP-ZS-9812 MKII
12 Channel Zone Selector
The ZS9812 MKII Zone Selector allows the selection of up to 12 individual zones, with a convenient ALL CALLS function to
provide activation for all the zones on the unit. When paging microphone is activated, the paging console will dictate the
selection of active zones in accordance to the settings. Similarly, once paging console is deactivated, the bypassed zones
shall revert back to the previous setting, providing both order and convenience to the users.
The ZS9812 MKII fits aptly into application that goes beyond the intended 12 zones. Configuration of the active zones can
be done either manually through front panel switches, or remotely via negative triggering method. When remote paging
microphone is in use, the zone selector switches on the unit will be temporarily deactivated, muting the BGM along the
way.
Product Features
• An ALL CALL button for simultaneous activation of all zones
• A priority triggering port feature for connection to handheld emergency paging microphone
• Priority relay to override DC signal
Specifications
Power Consumption
Zone Load Rating
Operating Voltage
Connections
Cable Size
Dimension (W x D x H)
Weight
Finish
Relay Trigger Output
Connect to
PMC-012
Relay Trigger Input
6:8W or 0.28A at ALL CALL
400W at 100V amplifier line output
24V DC via adaptor
Detachable connectors
Up to 2.5mm sq
484mm x 132mm x 44mm
2.1 kg
Black
To speaker
zone 1-6
Connect to
Connect to
PMC-012
amplifier 100v
To speaker
zone 7-12
Connect to
amplifier 100v
17

Advertisement

Table of Contents
loading

Summary of Contents for Flepcher FLP-ZS9812 MKII

  • Page 1 FLP-ZS-9812 MKII 12 Channel Zone Selector The ZS9812 MKII Zone Selector allows the selection of up to 12 individual zones, with a convenient ALL CALLS function to provide activation for all the zones on the unit. When paging microphone is activated, the paging console will dictate the selection of active zones in accordance to the settings.
  • Page 2 PUBLIC ADDRESS SYSTEM FLP-ZS9812MKII ZONE SELECTOR FLP-ZS9812MKII ALL CALL ZONE SELECTOR OVERRIDE SPEAKER ZONE SELECT Please follow the instructions in this manual to obtain the optimum results from this unit. We also recommend that you keep this manual handy for future reference.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS 1. SAFETY PRECAUTIONS ..................3 2. FEATURES .......................5 3. NOMENCLATURE AND FUNCTIONS 3.1 Front Panel ......................6 3.2 Rear Panel......................7 4. MACHINE OPERATION ..................8 5. APPLICATIONS .......................9 6.SPECIFICATIONS ....................10 7.DIMENSIONAL DIAGRAM ..................11 FLP-ZS9812MKII...
  • Page 4: Safety Precautions

    1. SAFETY PRECAUTIONS Be sure to read the instructions in this section carefully before use. Make sure to observe the instructions in this manual as the conventions of safety symbols and messages regarded as very important precautions are included. We also recommend you keep this instruction manual handy for future reference. Safety Symbol and Message Conventions Safety symbols and messages described below are used in this manual to prevent bodily injury and property damage which could result from mishandling.
  • Page 5 When Installing the Unit When Installing the Unit Never plug in nor remove the power supply plug Do not place heavy objects on the unit as this may with wet hands, as doing so may cause electric cause it to fall or break which may result in personal shock.
  • Page 6: Features

    2. FEATURES 1. Built-in independent partitions, with the region control. 2.12 amplifier audio signal input, 12 outputs, one correspondence. 3. Can be remote control district, the region features. 4. With a short-circuit signal control function of the region, and the short-circuit the signal output port. FLP-ZS9812MKII...
  • Page 7: Nomenclature And Functions

    3. NOMENCLATURE AND FUNCTIONS 3.1 FRONT PANEL FLP-ZS9812MKII ALL CALL ZONE SELECTOR OVERRIDE SPEAKER ZONE SELECT 1. OVER RIDE 2. Zoning button When it is light, other lights are off and Zoning indicator the ZONE1 ~ 12 after the board did not 3.
  • Page 8: Rear Panel

    NOMENCLATURE AND FUNCTIONS 3.2 REAR PANEL AMP 1 ZONE 1 AMP 2 ZONE 2 AMP 3 ZONE 3 AMP 4 ZONE 4 AMP 5 ZONE 5 AMP 6 ZONE 6 AMP 7 ZONE 7 AMP 8 ZONE 8 AMP 9 ZONE 9 AMP10 ZONE10 AMP11 ZONE11 AMP12 ZONE12 DC24V RELAY...
  • Page 9: Machine Operation

    4. MACHINE OPERATION 1. Panel 1 to 12 buttons and the corresponding channel indicator light after the plate AMP1 ~ 12 and ZONE1 ~ 12.Press the button corresponding to the channel after the board has a corresponding signal output (in the channel under the premise of an input signal),ALL ZONE button is pressed, after a 12-channel board can be output (100V).
  • Page 10: Applications

    5. APPLICATIONS REAR PANEL CONNECTIONS SHORT-CIRCUIT SIGNAL OUTPUT TO SPEAKER(100V) TO SPEAKER(100V) DC 24V AMP 1 ZONE 1 AMP 2 ZONE 2 AMP 3 ZONE 3 AMP 4 ZONE 4 AMP 5 ZONE 5 AMP 6 ZONE 6 AMP 7 ZONE 7 AMP 8 ZONE 8 AMP 9 ZONE 9 AMP10 ZONE10 AMP11 ZONE11 AMP12 ZONE12 DC24V...
  • Page 11: Specifications

    6.SPECIFICATIONS AUDIO AMPLIFIER RECEIVER MODULE MODEL FLP-ZS9812MKII AUDIO INPUT 100V 100V AUDIO OUTPUT DC 24V POWER REQUIREMENTS 484X132X44 DIMENSION(mm) WEIGHT 1.9kg FLP-ZS9812MKII...
  • Page 12: Dimensional Diagram

    7. DIMENSIONAL DIAGRAM UNIT:mm FLP-ZS9812MKII ALL CALL ZONE SELECTOR OVERRIDE SPEAKER ZONE SELECT AMP 1 ZONE 1 AMP 2 ZONE 2 AMP 3 ZONE 3 AMP 4 ZONE 4 AMP 5 ZONE 5 AMP 6 ZONE 6 AMP 7 ZONE 7 AMP 8 ZONE 8 AMP 9 ZONE 9 AMP10 ZONE10 AMP11 ZONE11 AMP12 ZONE12 DC24V...
  • Page 13 PUBLIC ADDRESS SYSTEM VersionV0.1...

Table of Contents