INSTALLATION INSTRUCTIONS
DUAL CURRENT SENSING GROUND FAULT INDICATOR MODULE
The Model 596SGFI is a dual channel current sensing ground fault detector module. In
conjunction with any IED Monitor/Test System, it can be used to monitor the current in
any speaker circuit, as well as to detect a fault to ground in either side of an amplifier
such as the IED Models 6270L/H or 6208L/H.
Figure 1 shows wiring of the 596SGFI using the 8000 Monitor/Test System. The 596SGFI
is connected to the an 8081MT Monitor/Test card through the 8048TBM Rear Terminal
Module.
Figure 2 shows the 596SGFI connected to the IED Model 596 Monitor/Test System. The
596SGFI is wired to the Model 596 Monitor/Test System rear panel screw terminal con-
nectors.
When multiple 596SGFI modules are powered from a single power supply, they can be
plugged together and mounted in a Snap Track as illustrated in figure 3.
FUNCTIONAL MODULES
MODEL 596SGFI DUAL CURRENT SENSING GROUND FAULT INDICATOR MODULE
MAY 2003
Last Edit: 06/17/03 01:09 pm
MODEL 596SGFI
10
53
SECTION
GROUP
SUB
B
1
PAGE

Advertisement

loading

Summary of Contents for IED 596SGFI

  • Page 1 MODEL 596SGFI DUAL CURRENT SENSING GROUND FAULT INDICATOR MODULE The Model 596SGFI is a dual channel current sensing ground fault detector module. In conjunction with any IED Monitor/Test System, it can be used to monitor the current in any speaker circuit, as well as to detect a fault to ground in either side of an amplifier such as the IED Models 6270L/H or 6208L/H.
  • Page 2 Normal current sensing is available with or without the power supply Power Amplifier Figure 1 - Connecting the 596SGFI to the 8000 Series Innovative Electronic Designs, Inc. 9701 Taylorsville Road Louisville, Kentucky 40299 USA Phone: (502) 267-7436 Fax: (502) 267-9070 Internet: http://www.iedaudio.com SECTION...
  • Page 3 INSTALLATION INSTRUCTIONS MODEL 596SGFI DUAL CURRENT SENSING GROUND FAULT INDICATOR MODULE A portion of the rear panel of the 596M Mainframe LEDs indicate the occurrence of a ground fault Plug into adjacent 596SGFI +5 VDC POWER SUPPLY Power supply is needed for...
  • Page 4 MODEL 596SGFI DUAL CURRENT SENSING GROUND FAULT INDICATOR MODULE INSTALLATION INSTRUCTIONS Figure 3 - 3 596SGFIs mounted in Snaptrackä and interconnected to share a power supply Innovative Electronic Designs, Inc. 9701 Taylorsville Road Louisville, Kentucky 40299 USA Phone: (502) 267-7436 Fax: (502) 267-9070 Internet: http://www.iedaudio.com...