Jetblack Safety JS-606 Series Instruction Manual

Personnel cleaning booth extractor

Advertisement

Quick Links

ACM-0002 Issue 3
PERSONNEL CLEANING BOOTH EXTRACTOR

Advertisement

Table of Contents
loading

Summary of Contents for Jetblack Safety JS-606 Series

  • Page 1 ACM-0002 Issue 3 PERSONNEL CLEANING BOOTH EXTRACTOR...
  • Page 2: Table Of Contents

    INSTALLATION | OPERATION | MAINTENANCE TABLE OF CONTENTS: GENERAL SAFETY INSTRUCTIONS INSTALLATION GUIDE EXTRACTOR OVERVIEW / DRAWINGS SET-UP / OPERATION MAINTENANCE INSTRUCTIONS SPARE PARTS MALFUNCTION-CAUSE-REMEDY WARRANTY INFORMATION MANUFACTURER SERVICE ADDRESS ENVIRONMENTAL VALUES DECLARATION OF CONFORMITY 2 of 17...
  • Page 3: General Safety Instructions

    GENERAL SAFETY INSTRUCTIONS • The extractor is controlled via the JetBlack Safety Cleaning Booth and will operate automatically without warning. Extreme caution is advised when carrying out any maintenance to the equipment. All electrical connections should be removed from the Cleaning Booth.
  • Page 4: Installation Guide

    The two brake castor wheels should be fitted at the fan end of the extractor base. See below image. • The JetBlack Safety extractor requires only the castors to be fitted before its ready to be connected to the Cleaning Booth. •...
  • Page 5: Extractor Overview / Drawings

    3. EXTRACTOR OVERVIEW / DRAWINGS Filter cover MR280S Fan Shaker motor Fan Motor Motor pedestal Trolley base X2 Locking wheels 5 of 17...
  • Page 6 Filter cover handle Extractor inlet Extractor drum Extractor handle Motor pedestal Collection bag 6 of 17...
  • Page 7 The hose-tail needs connecting to the Cleaning Booth LEV system via Ø8mm flexible air tube. If the extractor is not being used in conjunction with the Cleaning Booth, the hose-tail needs to be removed and replaced with a 1/8 BSP plug. 7 of 17...
  • Page 8 8 of 17...
  • Page 9 9 of 17...
  • Page 10: Set-Up / Operation

    4. SET-UP / OPERATION • The extractor is powered directly from the Cleaning Booth via two IP67 Blue Cable Mount 2P+E Industrial Power Plugs, Rated At 16A, 230 V and one IP67 Blue Cable Mount 2P+E Industrial Power Plug, Rated At 32A, 230 V.
  • Page 11: Maintenance Instructions

    5. MAINTENANCE INSTRUCTIONS Note: Before performing any maintenance, the extractor must be locked out and isolated from the electrical supply. Filter replacement: • Remove the filter cover by undoing the X4 M10 hex bolts, X1 M8 nut located on top of the filter cover. Use the X2 handles to lift the cover over the filter.
  • Page 12 • Replace the filter element and gasket making sure both mating surfaces are clear of any debris, secure using X4 M10 hex bolts. • Replace the filter cover with X4 M10 hex bolts, and X1 M8 nut. Note: Before performing any maintenance, the extractor must be locked out and isolated from the electrical supply. Waste collection bag removal: •...
  • Page 13: Spare Parts

    6. SPARE PARTS PARTS DESCRIPTION QTY REQUIRED PART NUMBER FILTER HEPA H14 JS-606/FILTER/H14 FILTER HEPA H10 JS-606/FILTER/H10 FILTER HEPA F7 JS-606/FILTER FILTER GASKET JS-606/33 FAN ASSEMBLY MR280S-00001 FAN GASKET JS-606/38 FILTER COVER JS-606/FILTER/COVER SHAKER MOTOR 8-708 SHAKER MOTOR AV MOUNTS 7-976 Filter cover Shaker...
  • Page 14: Malfunction-Cause-Remedy

    7. MALFUNCTION-CAUSE-REMEDY Malfunction Possible Cause Remedy Check and correct blower rotation if Incorrect blower rotation required These items MUST be changed regularly • Low flow, Low Dirty or contaminated filters (maximum of 6 months) dependant on amount of use Pressure Damaged hose lining Replace damaged hose Air leaks in system...
  • Page 15: Warranty Information

    8. WARRANTY INFORMATION JetBlack Safety is a trading name of Air Control Industries Ltd (ACI). Subject to the restrictions mentioned below, your equipment Warranty covers the repair or replacement, free of charge, of parts acknowledged to be faulty by Air Control Industries Ltd (ACI), as well as the labour necessary to repair the equipment for twelve months from the date of shipment*.
  • Page 16: Manufacturer Service Address

    9. MANUFACTURER SERVICE ADDRESS Air Control Industries Ltd Weycroft Avenue, Millwey Rise Industrial Estate, Axminster, EX13 5HU, UK www.aircontrolindustries.com sales@aircontrolindustries.com Tel: +44(0)1297 529242 Air Control Industries INC 76 Augusta Rockland Road, Windsor, Maine, USA www.aircontrolindustries.com/us inquiries@aircontrolindustries.com Tel: 207-445-2518 10. ENVIRONMENTAL VALUES WEEE RECYCLING &...
  • Page 17: Declaration Of Conformity

    11. Declaration of Conformity 17 of 17...