iPR-2
iPR3
Function
iPR-x proximity readers is intended to be applied in different access control systems, using RS232, Wiegand
26, Wiegand 37 or Wiegand 42 interface. (Reader iPR-9 have with built-in keypad).
Types of identificators
Smart Innovations manufactures readers operating with amplitude modulation (ASK) proximity cards and
tags.
Design
The reader is placed in miniature hermetic plastic or vandal-proof of polished stainless steel (iPR-3) case.
Thanks to the small overall dimensions the reader is distinguished for its advanced reliability.
Specifications
Warm-up time
Case
Material
Dimensions
iPR-2
iPR-3
mm 150х45х22 110х80х15 95x50x16 95х50х16 105-200
Weight
iPR-2
iPR-3
gramm 50
150
Ambient Conditions
Temperature
Humidity
Power supply
Voltage
Current
Maximal current up to 80 mA
Voltage ripple up to 500 mV.
Distance of reading
Typical reading distance show in table 1 and depends on tag type used with it. This parameter is valid for
power supply voltage range from +9 to +16 VDC and ripple up to 150 mV
Table. 1
Reader type
iPR-2
Distance, mm 150-160 35-40 105-200
Wiring
Reader has 8-wire colored cable intended for connection to access control panel.
Table 2. The wires assignment:
Multiwire signal cable with 0.22 mm
reader and control panel. Using this cable the maximum length of 50 meters can be obtained.
Type of interfaces
The proximity reader is intended to be applied in different access control systems, using RS232, Wiegand 26,
Wiegand 37, Wiegand 42 or TouchMemory interface.
Mounting
It is recommended to mount the reader on a wall closely to a door at
appropriate height.
!
Do not mount the reader on metal surface, since it causes decreasing of
reading distance.
!
If two readers are mounted at a distance less than 50sm, reading distance
of a card may be reduced appreciably. In such a case, connect yellow
wires of the readers. The readers will synchronize and work in turn.
!
Synchronization allows mounting of two readers at a small distance, to the
extent of reading distance of a card. In case that, two readers are mounted
at a distance less than reading distance of a card the card may be read by
the reader behind the wall.
To mount the iPR-2, iPR-3 readers proceeds as follows:
- Connect the reader to the control panel's cable
Smart Innovations
User manual of iPR-x proximity readers
iPR6
iPR-7
10 seconds after power start
ABS plastic (1.5 mm thick stainless steel iPR-3)
iPR-6
iPR-7
iPR-6
iPR-7
105
105
-35 . . . +65
С
0
100% (without condensate)
+9. . . +16 V of direct current
up to 50 mA
iPR-3 iPR-6
iPR-7
140-150
wires' cross-sectional is recommended to use for connection of the
2
iPR-8
iPR-9
iPR-8
iPR-9
105-200
iPR-8
iPR-9
94
94
p-p
iPR-8
iPR-9
105-200
105-200
1
.
Table. 2
W2/W3/W4/WS
Color
Function
Green
Data 0
White
Data 1
Red
+V
Black
GND
Brown
Red Led
Orange
Green Led
Blue
Beep
Yellow
Hold/Synch
RS232
Rx
Tx
+V
GND
–
–
–
Hold/Synch
Need help?
Do you have a question about the iPR Series and is the answer not in the manual?
Questions and answers