Wireless signal transmission system for safety edges, two channels
Translation of original operating instructions
General
50.8
10.8
1

Safety instructions

Warning: Switch off the operating voltage before working on the
system. Only trained, qualified personnel may perform installation
and startup. The unit may only be repaired by the manufacturer. The
switching unit may only be used to protect against dangers on
crushing and shearing points and on automatic industrial doors and
gates (intended use). National and international regulations on
industrial door and gate safety must be complied with. Always
2

Common application

2.1
Industrial door
Transmitter input 1 corresponds to receiver output 1
i
Transmitter input 2 corresponds to receiver output 2
ON
1
2
3
4
5
DIP switch 5 OFF
Receiver
50.8
10.8
Transmitter
Contact
(wicket door)
Safety edges
8.2 kΩ
Transmitter
Safety edges
Receiver
80
consider the safety functions of your application as a whole, never just in
relation to one individual section of the system. The installer is responsible
for carrying out a risk assessment and installing the industrial door system
correctly.
It is recommended to change the batteries every year.
i
2.2
Site entrance gate
Transmitter 1 input 1 corresponds to receiver output 1
i
Transmitter 2 input 1 corresponds to receiver output 2
Receiver
Transmitter 1
ON
1
2
3
4
5
DIP switch 5 ON
Transmitter 2
Receiver
Transmitter 2
Safety edges
Safety edges
8.2kΩ
8.2kΩ
Transmitter 1
Safety edges
341032D
01/19
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RFGate 2.2.NG and is the answer not in the manual?

Questions and answers

Summary of Contents for Bircher RFGate 2.2.NG

  • Page 1 341032D 01/19 RFGate 2.2.A RFGate 2.2.NG Wireless signal transmission system for safety edges, two channels Translation of original operating instructions General Transmitter Receiver 50.8 50.8 10.8 10.8 Safety instructions Warning: Switch off the operating voltage before working on the consider the safety functions of your application as a whole, never just in system.
  • Page 2 8K2 8K2 Change from NC to NO, see chapter 3.2 Input IN2 and DIP switch 2 only active at RFGate 2.2.NG (see paragraph 4.3, DIP switch 5) Change input from NC to NO (factory setting = NC) > 1.5 sec.
  • Page 3 10 sec. channel 2 Press and Beep Wait Code saved beeps release button LED goes out 6.2. RFGate 2.2.NG, pairing transmitter with receiver > 1.5 sec. On the receiver Beep Press Beep Release button button lights up On the...
  • Page 4 Devices with this symbol must be treated separately during disposal. This must be done in accordance with the laws of the respective countries for environmentally sound disposal, processing and recycling of electrical and electronic equipment. Contact BBC Bircher Smart Access, BBC Bircher AG, Wiesengasse 20, CH-8222 Beringen, www.bircher.com Designed in Switzerland / Made in EU...

This manual is also suitable for:

Rfgate 2.2.a

Table of Contents