7.3 Back up to USB memory stick............... 21 4.2.1 DC power connector (1) ................. 8 7.3.1 Making a backup of the content of the Zingui on a memory stick ....21 4.2.2 Headphones (2) ..................... 8 7.3.2 Restore the Zingui with the USB memory stick ..........22 4.2.3 USB port (slave) (3)..................
Page 5
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, translated to any language or transmitted in any form or by any means, be it electronic, mechanical, magnetic, optical, chemical, manual, recording, or otherwise without prior permission by Jabbla Jabbla www.jabbla.com...
Zingui should not be used for clinical, therapeutic or diagnostic applications. The Zingui is portable but it can also be mounted on a wheelchair. To ease the portability and to additionally protect the device a carry case is provided with the device.
The Zingui is a light weight portable device. When using mobile, we recommend to put the Zingui in its carry case and carry it in combination with the strap. This • The Zingui has a desk stand to allow you to put and use the device upright will avoid that the device drops from your hands on the floor.
2.3 The carry case The carry case allows you to carry and use the Zingui safely. The carry case will also protect the Zingui from dirt, moisture, shocks and bumps. Use the carry case in combination with the strap to avoid that the device can drop from your hands on the floor.
The on/off indicator will now blink every 4 seconds. The power consumption in standby mode is very low. Press the on/off switch to wake up the Zingui from the Standby mode. Waking up will take no time so that you can immediately restart to communicate.
The on/off switch (5) controls the power state of the Zingui. When completely switched off a short press on the on/off switch powers on the Zingui. Once the Zingui is powered on, a short press on the on/off switch will put the Zingui in 4.1.2 Microphone standby.
This is a 3.5 stereo mini-jack input connector for headphones. 4.2.3 USB port (slave) (3) The Zingui has two USB ports: a master and a slave. This mini USB port is the slave port. It is used to connect the Zingui to a computer to allow exchange of data between the computer and the Zingui.
Zingui 4.3.1 USB port (master) (1) The Zingui has two USB ports: a master port and a slave port. This is the master USB port. It can be used to connect a USB keyboard or USB mouse to the Zingui.
4.3.5 Reset button (5) In the event that the Zingui should not react anymore you can execute a reset by pressing the Reset button. The Zingui will be switched off. Press the on/off switch shortly to restart the Zingui.
Zingui is not active, charging the standard battery will take about 90 minutes (or Screw the battery lid back on the Zingui housing. 3 hours for the double capacity battery). You can use the Zingui while it is charged. In that case it will take longer to fully charge the battery.
Page 20
The Zingui will wake up instantly so that you can immediately continue to use the device. When you are using the Zingui every day you can put the Zingui in standby in the evening, charge it and wake up the Zingui in the morning.
• Keep pressed during the recording. Release when finished mode (if the option “Quick recoring” is enabled.) • Keep the Escape button on the back of the Zingui pressed during the 6.1 Making recordings in Recording mode recording. Release when finished.
1. Go to Tools > Options. Select Quick recording. 2. When you are working in Mouse mode and you want to make a recording, press the ESC button on the back of the Zingui and then select a cell. The 6. Tap to delete the recording.
6.4.1 Noise reduction Noise reduction stands in for a reduction of surrounding noises while recording. When this option is activated, Zingui will filter out the noise to improve the quality of recording. When Noise reduction and/or AGC are activated, wait a moment before speaking and do not speak too loud.
Zingui 2. Select Noise reduction. 6.4.2 AGC will try to set every recording to the same volume level. To activate AGC: 1. Go to Tools > Options and select Settings. 2. Select AGC. 3. Tap OK to confirm.
1. Go to Tools > Zingui and select Settings. The window Settings appears on the screen: 2. Choose whether you want to send the sound to the Speakers of the Zingui and/or to the phone (GSM)*. To modify these settings of the Zingui go to Tools > Zingui.
4. Shut down after (after going to Standby): Never - 5 hours - 10 hours - 20 hours - 25 hours. After the Zingui has been put in stand by mode, you can ask the Zingui to be shut down automatically after a specific time.
When you overwrite the recording of a specific cell, the previous recording will still be stored on the hard disk of the Zingui. When the free space on the hard 2. Go to Tools > Zingui > Back up to USB memory stick. Following window, disk is no longer sufficient, you can remove these old unused recordings.
USB, all changes will be lost. 7.4 Go to standby mode To put the Zingui in standby mode go to Tools > Zingui and select Go to 5. When copying is finished OK appears on the window. Standby.
Page 29
• Turn Microphone On: to turn the Microphone on • Turn Microphone Off: to turn the Microphone off • Toggle Microphone: to turn the Microphone on or off • Go to Standby: to put the Zingui in standby mode • Shutdown: to shut down the Zingui...
3. Put your remote control (in this example it will be the remote control of your television or cd player) in front of the IR window of the Zingui. The distance between your remote control and the IR window should be about two inches.
Repeat this procedure from (4) for all other command that you want to use. 8.2 Transmitting IR codes To send IR codes with the Zingui you have to link the command Send Gewa to a cell. 1. Go to Edit > Edit Mode.
Page 33
Zingui 2. The window restore appears on the screen. Select the backup you want to restore and tap OK. A sandglass will be displayed on the screen. When restoring is finished, the window disappears.
Page 35
Zingui Index Back up to USB memory disk 21 GEWA Backup 21 Backup of commands Programming IR codes Backup file of the GEWA commands 26 Restoring the GEWA backup Battery charging indicator 7 Transmitting IR codes Brightness Type command Automatically Adjust Brightness...
Page 36
Standby 20 Noise reduction 17 stop the scanning. 10 Switch input 10 Switch on 5 On/off indicator 7 Switch on the Zingui 5 On/off switch 7 Toggle Headphone 23 Record using noise reduction 17 Toggle Microphone 23 Recording Toggle speaker 22...
Need help?
Do you have a question about the Zingui and is the answer not in the manual?
Questions and answers