Energy Saving Products Hi-Velocity RCM-I Series Installation Manual

Refrigerant module for use with hvs-36 & hvs-60 variable speed heat pumps

Advertisement

Quick Links

Small Duct High Velocity Heating, Cooling and Home Comfort Systems
RCM-I Refrigerant Module
Installation Manual
For use with HVS-36 & HVS-60 Variable Speed Heat Pumps
RCM-I-70 (2.5-3 Tons)
RCM-I-100 (3.5-5 Tons)
Includes:
Service/Access Ports
L-Mounting Brackets
Double Sided Mounting Tape
Manufactured By
Carry-Over Screen
Module-RCM-I-Refrigerant-Module-Installation-050519

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Hi-Velocity RCM-I Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Energy Saving Products Hi-Velocity RCM-I Series

  • Page 1 Small Duct High Velocity Heating, Cooling and Home Comfort Systems RCM-I Refrigerant Module Installation Manual For use with HVS-36 & HVS-60 Variable Speed Heat Pumps RCM-I-70 (2.5-3 Tons) RCM-I-100 (3.5-5 Tons) Includes: Service/Access Ports L-Mounting Brackets Double Sided Mounting Tape Manufactured By Carry-Over Screen Module-RCM-I-Refrigerant-Module-Installation-050519...
  • Page 2: Mounting Brackets

    Module RCM-I RCM-I Installation www.hi-velocity.com Refrigerant Modules (RCM-I) Mounting Brackets The RCM-I cooling coil comes as a module and must be Mounting the cooling coil to the fan coil can be done with installed in the horizontal position on the return air side of the the L brackets supplied (Fig.
  • Page 3: Pipe Sizing

    Module RCM-I RCM-I Installation www.hi-velocity.com P - Trap Pipe Sizing The condensate drain must have a minimum 3” P-Trap Refer to charts below and Module HVS - Variable Speed Heat installed (Fig. 03), and run at a slope of ¼” per foot in the Pump Manual for pipe sizing.
  • Page 4: Outdoor Unit Installation

    Module RCM-I RCM-I Installation www.hi-velocity.com Outdoor Unit Installation Carry-over Screen Locate the outdoor unit in a suitable location, as close as All RCM-I refrigerant cooling modules come supplied with possible to the fan coil. Maintain the clearances recommended a nylon mesh carry-over screen and six stand-off plugs. The in the HVS Variable Speed Heat Pump manual to ensure proper Hi-Velocity units have a very high humidity removal rate, it is airflow.
  • Page 5: Return Air

    www.hi-velocity.com Return Air When sizing the return air ducts, keep in mind that if they are Where allowed by local codes, a single return air grill may be too small they can create noise, but if they are too large, the fan used.
  • Page 6 Module RCM-I RCM-I Installation www.hi-velocity.com RCM-I Specifications Refrigerant Cooling Module Specifications RCM-I-70 RCM-I-100 HE-Z/HE-B/HE/HV-70/71 Matching Fan Coil HE-Z/HE-B/HE-P/HE/HV-100/101 LV-70 Part Number 10090203070 10090203100 Tons 2.5 - 3.0 3.5 - 5.0 (8.8 - 10.6 Kw) (12.3 - 17.6 Kw) Refrigerant Type R-410A R-410A TX Cooling MBH...
  • Page 7: Warranty

    WARRANTY Energy Saving Products Ltd. is proud to offer a limited warranty. This warranty applies strictly to the first purchaser at wholesale level and only to the fan coil unit and module. It does not include connections, attachments and other products or materials furnished by the installer.
  • Page 8 Our facilities house Administration, Sales, Design, Manufacturing, as well as Research & Development complete with an in-house test lab. Energy Saving Products prides itself on Customer Service and provides design services and contractor support.