• Use the unit only when it is in a technically sound condition. Do not modify the device's components in any way. • It must be ensured that indoor air is circulating round the SENSOAIR. • Ensure that the device's ventilation openings are kept free and are not blocked by other equipment, furniture or objects.
Insert the Euro mains plug of the standard connecting cable only into a suitable 230 V AC mains power supply socket. If the mains connection cable for the unit is damaged, it must be replaced by SIEGENIA, its customer service or an equally qualified person to eliminate hazards.
Installation and operating instructions SENSOAIR 4. Description of device The SENSOAIR is an air sensor for checking the quality of air in closed rooms. 4.1 Device types SENSOAIR type plus smart Table unit version − Wall-mounted version Measure/display CO function...
The fuses may need to be removed. 5.2 Additional requirements for SENSOAIR smart • The SENSOAIR should be installed to be as free from interference as possible. The following interferences can have a negative influence on the WLAN signal: Water lines...
Page 7
Installation and operating instructions SENSOAIR 5.3 Installation steps 1. Remove the casing cover Note: In the delivered state, the cover is not clipped on. If it does need to be removed, insert a suitable object (e.g. coin or screwdriver) into the gap in the retention catches and twist to lever the cover off the casing.
Page 8
SENSOAIR Installation and operating instructions 3. Pull the power cable through the relevant cable cut-out (b or c). 4. Position the bottom part of the casing and use it as a drilling template. 5. Drill the holes for wall mounting.
Page 9
SENSOAIR 8. Optional: Connect devices (SENSOAIR plus only). SENSOAIR plus controls the connected devices via 230 V AC or 24 V DC control lines. The devices are connected to a relay circuit board. For wiring diagrams see from Page 4 Relay circuit board 24 V DC control lines...
Page 10
SENSOAIR Installation and operating instructions 9. Optional: Device control (see Page 13 onwards) 10. Clip on the casing cover 03.2017...
Installation and operating instructions SENSOAIR 6. Wiring diagrams for SENSOAIR plus 6.1 Ventilation units AEROMAT VT RS, AEROVITAL, AEROLIFE, AEROMAT VT WRG 1000 AEROPLUS, AEROPAC SN, AEROMAT VT WRG 1100 AEROVITAL ambience Switch distribution box, provided by Switch distribution box, provided by...
Page 12
Switch distribution box, provided Switch distribution box, provided by customer by customer Power supply VPS1 Power supply VPS1 sw rt SENSOAIR plus SENSOAIR plus − sw = black M- 24 V DC rt = red M- 24 V DC DRIVE...
Installation and operating instructions SENSOAIR 7. Device control 7.2 SENSOAIR plus • All connected devices are activated/deactivated using preset air quality values. • The presettings are made by means of DIP switches on the basic circuit board. Important: Do not switch on the power supply until all DIP switches have been configured.
Page 14
4. Both relays switch off after 90 seconds and the test is complete 7.2 SENSOAIR smart The SENSOAIR smart can be controlled by a tablet or smartphone. Please follow the enclosed quick start instructions (H47.MOTS005EN). Overview of the device functions •...
8.1 Automatic calibration of the CO and VOC sensors • The sensors are calibrated automatically as soon as the SENSOAIR is connected to the power supply (and also following a power failure). • The LED makes 1x long green flash during the calibration.
In case of a malfunction, do not open the device or try to repair it under any circumstances. If the problem is not listed in the table below, please contact your installation firm or SIEGENIA directly: Tel. +49 271 3931-0...
350 ppm. A level of above approx. 800 ppm negatively impacts our well-being. • If the CO content or the VOC concentration exceeds the following values, SENSOAIR indicates this using the LED traffic light and connected devices are activated. • The concentration of CO in a room depends on the number of people in the room, the length of time that they spend in that room, the volume of the room and the air change rate.
Although our products do not fall within the scope of the German Electrical and Electronic Equipment Act, SIEGENIA will continue to meet the requirements of this Act and will endeavour to completely eliminate the use of substances that are hazardous to the environment as soon as this becomes technically feasible.
14. EU Declaration of Conformity with regard to CE marking For our product SENSOAIR, we confirm that the general safety of the defined product, in accordan- ce with Directive 2001/95/EC, is compliant with the relevant protection requirements which are laid down in the Council Directives about electrical and electronic products.
Page 20
Phone: + Industriestraße Telefax: + Wilnsdorf info@sie enia.com GERMANY www.sie enia.com Hun ary Phone: + SIEGENIA worldwide: Austria Phone: + Italy Phone: + Belarus Phone: + Poland Phone: + Benelux Phone: + Russia Phone: + China Phone: + South Korea Phone: +...