Installation Manual
BE SURE TO FOLLOW
THESE PRECAUTIONS AND
INSTRUCTIONS
These safety precautions are essential for safe
installation and use of the product.
Please read the precautions thoroughly before
installing the product.
Do not pour water or cleanser
inside or on the body and remote
control, or on the power plug.
*There is danger of electric shock or fire.
Do not pull out or insert the power
plug with wet hands.
*There is danger of electric shock.
Do not install or leave the main
body or remote controller in a
constantly humid location or
location where water, liquid or
splash may affect them.
Do not use any power supply other
than AC 220 V. Do not use any
other method to connect the plug to
an improperly configured receptacle.
*Use of exceeding the rated voltage could cause fire.
Lead water from a system that
provides drinkable water. If dirt or
impure substances clogs the strainer,
install a filter to the water inlet.
●Use an receptacle with a maximum rating of AC 220 V and 1200 W.
●The length of the power cord is 1.2 m.
Install the receptacle so that it is within reach of the power cord and high enough from the floor so that water won't splash on it.
●Be sure to install a ground (Class 3 ground terminal construction).
* Ask an electrical contractor to install the wiring.
* Do not insert the power plug in the receptacle until installation is completely finished.
Doing so may cause system failure.
Water Supply
●Be sure to connect the water supply parts to the potable water line.
If surface water, industrial water or well water is used, it may cause
deterioration of electrical and mechanical parts and lead to accidents.
Water Pressure
●The minimum operating water pressure when 20 L/min. is
flowing is 0.1 MPa {1.0 kgf/cm
pressure is 0.75 MPa {7.5 kgf/cm
Even if other fixtures are used simultaneously, a supply water
pressure of 0.1 MPa {1.0 kgf/cm
MPa {7.5kgf/cm
2
} is required. If this minimum water pressure is
not reached, pressure will be insufficient to operate the product's
cleaning functions.
DV-218-VH-W (GBC-941SU-AY)
Explanation of Terms and Symbols
WARNING···
CAUTION ···
NOTE
WARNING
Absolutely do not allow anyone except
an authorized service technician to
disassemble, repair or modify this product.
DON'T POUR
WATER
*There is danger of electric shock, or fire, causing injury.
Do not use a receptacle that is loose and
in which the plug does not fit snugly.
NO WET
*There is danger of electric shock or fire.
HAND
Do not nick, damage, carve, bend unduly, pull
on, twist, bind or place heavy objects on top of
the power cord, or pinch it between two objects.
FORBIDDEN
*The above could damage the electrical conductors
and cause electric shock or fire.
Make sure that the earth wire is
properly fixed.
*Otherwise it may electrify the user in case
FORBIDDEN
of malfunction or a short circuit.
*Consult your electrician if there is no earth terminal
around the power point.
Thoroughly insert the power plug to
the power point.
* Otherwise, it may cause fire or electrify
OBSERVE
the user.
Power Supply
2
} or greater. The maximum water
} under hydrostatic pressure.
2
2
} or greater and less than 0.75
Indicates a potentially hazardous situation which, if not avoided,
could result in death or serious injury.
Indicates a potentially hazardous situation which, if not avoided,
may result minor or moderate injury or in damage to other
property.
···
Indicates a potentially hazardous situation, if not avoided, may
result in damage to other product.
Porcelain is breakable.
●Before installation, make sure the toilet
bowl is not cracked or otherwise damaged.
DON'T
DISASSEMBLE
●When installation is completed, check the toilet to
make sure it has not been damaged during the
installation work.
*Damaged parts could cause injury or water
leakage and soaking in the bathroom.
FORBIDDEN
Be sure to adjust the water shutoff
valve and check for water leakage
after installation.
FORBIDDEN
*Household articles may get wet if there is water leakage.
●When removing the strainers, be sure
to close the water shutoff valve.
●When installing the strainers, tighten if
EARTH
fully until the line is hidden by the body.
*Household articles may get wet if there is water leakage.
If freezing weather is anticipated
before handing the product to the
customer, keep the water drained out.
*Freeze damage may cause water leakage or
OBSERVE
damage household articles.
Minimum Installation Clearance
●The amount of space required for this toilet is shown in the following diagram.
At least 400 mm of clear space is required in front of the toilet in order for the
open/close function of the non-touch toilet seat lid to operate correctly.
1050 or more
CAUTION
OBSERVE
OBSERVE
OBSERVE
OBSERVE
400 or more
(mm)

Advertisement

loading

Summary of Contents for Inax SATIS DV-218-VH-W

  • Page 1 PCW-1115-W(08100) Installation Manual DV-218-VH-W (GBC-941SU-AY) Explanation of Terms and Symbols BE SURE TO FOLLOW THESE PRECAUTIONS AND WARNING··· Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. INSTRUCTIONS CAUTION ··· Indicates a potentially hazardous situation which, if not avoided, may result minor or moderate injury or in damage to other These safety precautions are essential for safe property.
  • Page 2 Positioning of water supply and drain pipes Remote Control Unit Mounting Location As much as possible, install the remote controller on the wall on the side where the remote controller receptor is located. Drain pipe Water supply 1/2B If the remote control unit is If the remote control unit is (VP100, VU100, VP75, or VU75) (in case of supply from the wall)
  • Page 3: Installation

    Please note that the following installation steps 4 to 7 varies depending on the distance between the wall and the centre of the soil pipe. Distance between the wall and the centre of the soil pipe If the distance is between 200 and 450mm, go to section A. If the distance is between 451 and 580mm, go to section B.
  • Page 4 ●Please read this installation manual carefully in order to install the product correctly. NOTE ●Be sure to perform trial operation after installation. ●Be sure to hand this manual, User's Manual, and a warranty card to the customer. Explain how to use the product when you hand it over to the customer. Distance between the wall and the centre of the soil pipe: 200 - 450mm NOTE 2 ●...
  • Page 5 Distance between the wall and the centre of the soil pipe: 451 - 580mm NOTE 2 ● Never drop the drain adjuster or flange on the Cutting the Drain Adjuster floor by mistake. It may cause water leakage from the damaged part. Cut the drain adjuster for 100mm as shown in the ●...
  • Page 6: Installing The Body

    Mounting the Toilet Bowl NOTE 7 Do not place the toilet bowl on the pedestal or drain socket. (1) Insert the drain pipe of the toilet bowl in the rubber drain socket joint, Otherwise it may damage the socket or packing Mounting Fastener Drain Pipe then position thetoilet bowl with the front end raised up and loose.
  • Page 7: Connecting The Power Supply

    Installing the Water Supply Hose (Water shutoff valve side) NOTE 18 Do not bend the water supply hose at a sharp angle. (1) Remove the cap from the end of the water supply hose, then Installation There is danger of its becoming insert it in the water supply outlet of the water shutoff valve.
  • Page 8 Water leakage check NOTE 24 1. Turn the Open/Close handle of the water 2. Check to make sure there is no water leakage. shutoff valve to the fully open position and Repeat the test to check on (1) Operate the remote control unit, flushing the toilet water leakage from the water several times.