Download Print this page

TDK J Series JBW Specification Sheet page 6

Ac input single output, general-purpose, ul/c-ul/tüv approved

Advertisement

JBW30W Type
SPECIFICATIONS AND STANDARDS
Part No.
Rated output voltage and current
Maximum output power
Input conditions
Input voltage Eac/Edc
Input frequency
Input current
Fuse rating
Surge current
Leakage current
Power factor
Efficiency
Output characteristics
Output voltage Edc
Voltage variable range Edc
Maximum output current
Minimum output current
Overvoltage threshold Edc
Overcurrent threshold
Source effect
Load effect
Voltage
Temperature effect
stability
Drift(Time effect)
Recovery
Ripple Ep-p
Ripple noise Ep-p
Start up time
Hold up time
Auxiliary functions
Indicator display
Overvoltage protection
Overcurrent protection
Remote ON-OFF
Remote sensing
Parallel operation
Series operation
Output voltage external variable function
Standards
Safety standards
Noise terminal voltage
Input harmonics current requirement
Constructions
External dimensions
Weight
Mounting method
Case material
Current rating(maximum output current) is determined for –10 to +50°C. Derating is required when used outside this temperature range.
• Optional input, output cable kits are available at a separate price.
• All specifications are subject to change without notice.
JBW05-6R0
5V • 6A
W
30
V
85 to 265[Rating: 100 to 240]/110 to 370
Hz
47 to 440[Rating: 50 to 60](Single phase)
A
0.65typ./0.86max.[AC.100V]0.35typ./0.48max.[AC.240V]
A
2[AC.250V, built-in]
A
15typ./30max.[AC.100V]30typ./60max.[AC.240V] 1st surge current, cold start, reset after 1s minimum.
mA
0.35typ./0.75max.[AC.100V, 60Hz]0.5typ./0.75max.[AC.240V, 60Hz]
0.6typ./0.45typ.[AC.100/240V]
%
75typ.[AC.100V]
%
77typ.[AC.240V]
V
5
V
Fixed
A
6
A
0
V
5.6min.
A
6.3min.
%
0.4max.[Within the input voltage range]
%
0.8max.[0 to 100% load]
%
2max.[Ambient temperature: –10 to +50°C]
%
0.4max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
%
±4max.[50 to 100% sudden load change]
mV
80max.
mV
120max.
ms
650max.(350typ.)/320max.(130typ.)[AC.100/240V]
ms
20typ./160typ.[AC.100/240V]
No
Voltage shut-down type.
Rectangular type(Winker operation), automatic recovery.
No
No
Impossible
Impossible
No
UL60950-1, CSA C22.2 No.60950-1(C-UL), EN60950-1(TÜV) approved.
FCC-B, VCCI-B, EN55011-B, EN55022-B meet.
No
mm
26× 55× 122[H× W× L]
g
150max.
Can be attached to 1 side.
No(PWB Material: CEM3)
JBW12-2R5
JBW15-2R0
12V • 2.5A
15V • 2A
30
30
78typ.[AC.100V]
79typ.[AC.100V]
79typ.[AC.240V]
80typ.[AC.240V]
12
15
Fixed
Fixed
2.5
2
0
0
13.3min.
16.6min.
2.7min.
2.1min.
120max.
120max.
150max.
150max.
(6/30)
JAW24-1R3
24V • 1.3A
31.2
80typ.[AC.100V]
81typ.[AC.240V]
24
Fixed
1.3
0
26.5min.
1.4min.
120max.
150max.
004-02 / 20070523 / ea122_jbw.fm

Advertisement

loading