Download Print this page

TDK NB-59S-09S-0 User Manual page 2

Ultrasonic nebulizer units humidifier for mist generating system incorporate type

Advertisement

Ultrasonic Nebulizer Units
Incorporate Type
NB Series
The TDK ultrasonic humidifier unit was the first such product in the
world to be developed. There is an increasing need for indoor
humidification due to the proliferation of clean air heat pumps and
central heating systems.
When the appropriate amount of humidity is added as determined
by the relationship between humidity and sensible temperature
(temperature perceived by the body), humidification is advanta-
ELECTRICAL CHARACTERISTICS
Part No.
Eac(V)
Rated input voltage
Edc(V)
Power consumption (W)
Mist output ratio (l/h)
Ultrasonic frequency (kHz)
Normal water level (mm)
External potentiometer (k )
Operating water temperature range (°C)
Water quality
Transducer element life (h)
Cooling method
Parallel connected operation
Weight (g)
Main application
• The character at the end of the product number indicates the transducer's direction of tilt.
EXAMPLE OF ATOMIZATION CHAMBER CONSTRUCTION
Mist
Mist discharge tube
Atomization chamber
Air-flow
Water tank
Transducer
Drive
circuit
Ultrasonic humidifier unit
Fan moter
TYPICAL CHARACTERISTICS OF HUMIDIFIER UNITS
VOLTAGE CHARACTERISTICS(48V)
+40
+20
Input voltage ratio ( % )
–30
–20
–10
48V+10
+20
( 33.6V )
( 38.4V )
( 43.2V )
( 52.8V )
( 57.6V )
–20
–40
–60
• All specifications are subject to change without notice.
NB-59S-09S-0
48±10%
30±5
45010
–3
min.
1600 to 1750
40
0 to 45
Drinking water
10000
Water cooled
Yes
60
Various humidity control systems
Float switch
Power transformer
WATER TEMPERATURE CHARACTERISTICS(48V)
700
600
+30
( 62.4V )
500
10
Water temperature ( ˚C )
geous from the standpoint of both health and reduced energy con-
sumption.
In addition to such home uses, these ultrasonic humidifier units
have numerous advantages for humidification of vegetable show-
cases, preservation and growth of agricultural products, industrial
applications, etc. A wide variety of standard units are available
from TDK.
TYPICAL TRANSDUCER INSTALLATION
Air-flow
The direction of
water column
Transducer
(tilted about 7°)
13mm
20
30
40
50
NB-80E-01-H
12±10%
13.2max.
(150+100, –50)10
–3
2350 to 2600
35
10
0 to 45
Drinking water
5000
Air cooled
Yes
60
Microparticle applications such as for medical use
Tilt directions of the transducer
NB-59S-09S Type
The arrows indicate the tilt direction
of the transducer.
The tilt direction of transtucer will be the
same as the direction of water column.
WATER LEVEL CHARACTERISTICS
600
400
200
30
35
40
Water level ( mm )
002-03 / 20120316 / ef441_nb.fm
(1/3)
Transducer
48V series
24, 12V series
45
50

Advertisement

loading

This manual is also suitable for:

Nb seriesNb-80e-01-h