Important Note - EA -PS 3032-10 B Manual

Laboratory power supply
Table of Contents

Advertisement

Available languages

Available languages

Important! The signal ground (GND) of the analogue interface and the positive (+) output are internally con-
nected. When wiring the signal ground to a control application (eg. a SPS) and the negative (-) output to a
load, they must not be connected to each other, because it will be a short-circuit and high current will flow
through the signal ground and damage the device.
In order to measure the voltage at the load, use and wire the „Remote sense" feature. The actual value output UMON,
represents the voltage on the load and can be wired with the control application to measure the voltage. This prevents
the current flowing via the control resp. measure lines.
© EA Elektro-Automatik GmbH & Co. KG , DE-41747 Viersen , Helmholtzstr. 31-33 , TEL. 02162-3785-0, FAX. 02162-16230
Correct

Important note

8
Wrong

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ps3000b series

Table of Contents