2-3.
MEMORY WRITE CONFIRMATION METHOD
1. After completing all adjustments turn the set off with the Remote Commander and WAIT for the fans to turn off before proceeding to the next step.
Note: It may take up to two minutes for the fans to stop.
Caution: To avoid over heating the lamp, do not unplug the set until the fans have stopped.
2. After the fans have stopped, unplug the set from the AC outlet, then plug the set back in the AC outlet.
3. To verify the changes repeat steps 2 through 5 from sections 2-1. Setting the Service Adjustment Mode and 2-2. Service Adjustment Mode Memory.
4. To exit service mode, turn the power off.
Note: To restore the User Controls and Channel Memory settings to the preset factory conditions, put the set into service mode (step 2
from 2-1. Setting the Service Adjustment Mode), then press 8 then ENTER on the Remote Commander. The set will restart and display the
initial setup screen.
2-4.

REMOTE ADJUSTMENT BUTTONS AND INDICATORS

KDF-42WE655/50WE655
All manuals and user guides at all-guides.com
MUTING
Write into
memory
Adjustment
1
item up
Category up
2
Adjustment
4
item down
8
Restore User Control
and Channel Memory
VOLUME (+)
POWER
DISPLAY
3 Data value up
6 Data value
down
5 Category down
ENTER
0
Read data
from last
saved NVM
JUMP
Displays Service Menus