Hide thumbs Also See for RR Series:

Advertisement

RR ...
Dispensers
ERR ...
Issue: 2011-01-04
Pipe dispensers R ...
round, RR ...
• • • •
square, RE ...
• • • •
Exchange dispensers WE ...
Platform dispensers P ...
open, PO ...
• • • •
closed, PG ...
• • • •
circulating air-heated, PU ...
• • • •
Ultra dispenser REU ...
Built-in dispensers ERR ...
Original user guide
PO ...
ERR ...

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RR Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Rieber RR Series

  • Page 1 PO … RR … Dispensers Pipe dispensers R … round, RR … • • • • square, RE … • • • • Exchange dispensers WE … Platform dispensers P … open, PO … • • • • closed, PG … •...
  • Page 2: Table Of Contents

    Choose the correct cleaning method........................ 28 Clean and service stainless steel parts ......................28 Cleaning the casters ............................28 Clean and service plastic parts ........................29 Dry the appliance to keep it ready for next use ....................29 Rieber GmbH & Co. KG...
  • Page 3 Contents 10 Fault - What now? ............................29 11 Warranty and liability............................ 31 12 Address of manufacturer..........................32 Rieber GmbH & Co. KG...
  • Page 4: Revision Index

    If there are any deficits from your point of view, please do not hesitate to let us know. With your help, we will try to get even better. Please add your notes here: Rieber GmbH & Co. KG...
  • Page 5: Representation Conventions In The Text

    Failure to follow these warning instructions may cause serious bodily injury or even death. CAUTION! indicates a potentially harmful situation. Failure to follow these warnings may cause minor bodily injury. Rieber GmbH & Co. KG...
  • Page 6: Description Of Product

    50/60Hz. Environmental conditions +5° C up to +40° C. Casing with double-wall insulation. Cooling unit refrigerant R134a. Emitted sound pressure level closed 52.0 dB, emitted sound pressure level open 61.5 dB. Protection class IPX5 according to DIN EN 60529 (jet-proof, nozzle, from any angle). Rieber GmbH & Co. KG...
  • Page 7: Accessories And Their Use

    These products may only be moved manually, machine-supported moving is not • • • • permissible. When transporting mobile units, wear safety shoes. • • • • Rieber GmbH & Co. KG...
  • Page 8: Use Of Pipe Dispensers R

    … provided with ventilation slots. For pre-cooling plates etc. in cold or freezer rooms With RRV 190-280: from Ø 190 mm to Ø 280 mm. With RRV 230-320: from Ø 230 mm to Ø 320 mm. Rieber GmbH & Co. KG...
  • Page 9: Use Of Exchange Dispensers We

    6 change rods can be installed as required in 18 holes. Adjustable for crockery parts • • • • of different sizes. Max. load capacity 150 kg • • • • WE-H WE-Q 1/1 R … R … Rieber GmbH & Co. KG...
  • Page 10: Use Of Platform Dispensers Po

    Platform dispenser, open ― ... Food distribution ― … Gastronorm ― … square ― SV1/1 Special design with side tray guide for tray stacking ― TA1/1 Special design with side tray guide for tray stacking Rieber GmbH & Co. KG...
  • Page 11 PU … PU-M R … Type identification: Platform dispenser, circulating air heated ― … Gastronorm ― ... food distribution ― … square ― … stainless steel hinged lid; only suitable for stainless steel baskets Rieber GmbH & Co. KG...
  • Page 12: Use Of Ultra Dispensers Reu

    Purpose 4.5 Use of ultra dispensers REU ... Generally, the following are intended uses for the product: For stacking and dispensing and heating of heat/ultra bowls from Rieber. • • • • REU-P R … Type identification: Ultra dispenser REU ―...
  • Page 13: General Safety Instructions

    Make sure the appliance cannot be switched on unintentionally. Double check that the • • • • main switch is in the "OFF" position before inserting the plug in the socket. Connecting the appliance to the power supply while it is switched on can cause an accident. Rieber GmbH & Co. KG...
  • Page 14 Service Only have the device repaired by qualified and authorised staff. Only use original spare • • • • parts. In this way you can ensure that the appliance remains safe. Rieber GmbH & Co. KG...
  • Page 15: Operator's Duties

    Only ‘Qualified Staff’ is allowed to carry out repair work. • • • • IEC 60204-1 defines qualified personnel as "persons who, on account of their training and relevant experience are in the position to recognise risks and avoid potentially dangerous situations." Rieber GmbH & Co. KG...
  • Page 16: Provide Protective Equipment For Personnel

    ► Finally remove the securing bar/rod taking proper care due to the pre-loaded parts. Also refer to ‘Adjust the dispenser to the crockery used’, page 19 Rieber GmbH & Co. KG...
  • Page 17: Information About Regulations To Be Followed

    User tip ► Inform yourself in detail taking the company-internal instructions as a reference. Remember the rules of conduct. ► We recommend that half-yearly emergency training sessions should be carried out. Rieber GmbH & Co. KG...
  • Page 18: Before First Use

    Protective foils or heat-sensitive objects at/in the appliance might damage the appliance during heating. ► Ensure that there are no protective foils in the inside and on the outside of the appliance. Clean the appliance See chapter ‘Cleaning, maintenance and care’, page 27 Rieber GmbH & Co. KG...
  • Page 19: Adjust The Dispenser To The Crockery Used

    Fix adjustment rod (1) in bottom hole (4). All adjustment rods must be fixed in the corresponding hole. ▌ Between the adjustment rods (1) and plates, there should be a continuous gap of 2 to 5 mm in order to compensate for crockery tolerances. Rieber GmbH & Co. KG...
  • Page 20 Spring adjustment is ideal if approx. 3 to 6 plates project over the edge of the pipe. If more plates project, remove the springs again. If too few plates project, install springs. After adjustment of the pipes, reinstall them in the dispenser carefully. Rieber GmbH & Co. KG...
  • Page 21: Exchange Dispensers We

    Between the change rods (1) and plates, there should be a continuous gap of 2 to 5 mm in order to compensate for crockery tolerances. After adjustment, lock all spring clips again, using the tool. Rieber GmbH & Co. KG...
  • Page 22 Spring adjustment is ideal if approx. 3 to 6 plates project over the edge of the pipe. If more plates project, remove the springs again. If too few plates project, install springs. After adjustment of the pipes, reinstall them in the dispenser carefully. Rieber GmbH & Co. KG...
  • Page 23: Platform Dispenser Po

    Ensure that the dispensing level is always above the lower edge of the casing. 7.3 Platform dispenser PO … 1 hexagon socket screw 3 removed spring 2 suspended spring Apply parking brake and unplug mains plug. Rieber GmbH & Co. KG...
  • Page 24: Ultra Dispenser Reu

    7.4.1 Built-in dispensers E… Procedure See chapter ‘Pipe dispenser R …’, page 19 When reinstaling the adjustable pipe, insert the 3 locking clips (1) in the corresponding cutouts (2) at the upper termination ring of the jacket. Rieber GmbH & Co. KG...
  • Page 25: Information On Using The Product

    Always secure the unit in its position by applying the parking brake. The socket outlet must be easily accessible so that the unit can be disconnected • • • • from power supply at any time. Rieber GmbH & Co. KG...
  • Page 26: Operation

    Estimate the heating/cooling time until the temperature is reached realistically. If the appliance is used for cooling, only use pre-chilled meals. Remove crockery Remove lid directly before portioning only. Remove crockery evenly (if there are several crockery parts on platform). Rieber GmbH & Co. KG...
  • Page 27: Cleaning, Maintenance And Care

    Do not use a steam cleaning unit to clean electrical appliances. Doing so may allow moisture to get into the electrical system and cause a short circuit. ► Electrical appliances used in rough conditions should be checked by a qualified electrician every 6 months at the latest. Rieber GmbH & Co. KG...
  • Page 28: Choose The Correct Cleaning Method

    Clean the appliance with a mild detergent diluted in hot water. After cleaning, rub surfaces dry with a soft cloth. User tip ► We recommend Rieber cleaning agent for stainless steel for cleaning stainless steel. ▌ Is an especially tough yet soft cleaner, produces a dazzling shine, cleans and protects in one.
  • Page 29: Clean And Service Plastic Parts

    ERRV-H..., ERE-H Sensor not fixed properly. Disconnect appliance from or heated plate dispenser power supply, switch off heats up too much existing circuit breakers/fuses in switchbox. Repair Qualified electrician Repair. Plug / spiral cable / rocker Rieber GmbH & Co. KG...
  • Page 30 Replace defective springs. User See page 19 In the case of round pipes, adjust rods centrically. User See page 19 Distribute springs evenly across the circumference. User See page 19 Replace defective spring. Spring defective User Rieber GmbH & Co. KG...
  • Page 31: Warranty And Liability

    Customer service, spare parts IMPORTANT Customer service needs information about the type and number of the appliance. If you have a fault you cannot remedy yourself, please get in touch with your Rieber partner or Rieber central customer service. Disposing of your product Your appliance is made of high-quality material which can be reused / recycled.
  • Page 32: Address Of Manufacturer

    Address of manufacturer 12 Address of manufacturer Rieber GmbH & Co. KG Hoffmannstraße 44 D-72770 Reutlingen, Germany Phone +49 (0) 7121 518-0 +49 (0) 7121 518-302 Email info@rieber.de www.rieber.de Rieber GmbH & Co. KG...

Table of Contents