EnOcean will not be reliable for consequences of any HW or SW changes/modifications of the developer board(s) done by the developer. Before using EDK 300 please consider country specific radio regulations and frequencies, e.g.
EDK 300 Getting Started 1 Introduction EDK 300 and EDK 300C are designed to support hardware and software application development for following EnO- cean modules: 868 MHz (EDK 300): TCM 3x0, STM 300 315 MHz (EDK 300C): TCM 3x0C, STM 300C TCM 320 Content of EDK 300 Developer‟s Kit:...
EDK 300 Getting Started USB power supply 2.2 Default Configuration Power Management: Power Switch (On/Off) USB connector for external power supply Mode and configuration jumper for TCM 300 Standard FW: MODE 1: Serial bidirectional mode MODE 2: 1 channel receiver mode ...
5. Switching PTM 2x0 will toggle CH0 LED (relay pin) Attention: If you have changed TCM firmware: Load EnOcean TCM 300 default firmware from CD If you have changed mode settings: Clear ID - press CLEAR button > 2s (LEDs “LMI”...
/ not equipped Attention: If you have changed FW: Load EnOcean TCM 300 default firmware from CD If you have changed mode settings: Clear ID - press CLEAR button > 2s (LEDs “LMI” will light & “CH0” blink)
DolphinView Visualize properites of EnOcean radio nodes Receives, sends and analyses radio telegrams according to the EnOcean standard Get detailed information e.g. subtelegram timing and signal strength Content of telegrams can be analyzed online and logged with time stamp ...
EDK 300 Getting Started 3.3 DolphinStudio Installation Launch DolphinStudio setup pro- gram and follow instructions Connect EOP300 to PC via USB cable Press “Options” button within menu “Options” window will appear, press “Refresh” to recognize EOP 300 programmer Programmer settings/firmware will...
3.4 Check FW Version with DolphinStudio Connect EVA 300 or EVA 320 with STM/TCM 3x0 plugged via EOP 300 to PC Launch DolphinStudio Select “EOPX (Program- mer)” tab Select “Chip information” Press “Retrieve” button Current application type and version e.g. “TCM 300 2.0.0.0”...
EDK 300 Getting Started 3.5 Update Module FW with DolphinStudio Connect EVA 300 or EVA 320 with STM/TCM 3x0 plugged via EOP 300 to PC Launch DolphinStudio Select “EOPX (Programmer)” tab Select “Programmer” Select FW file via “Browse…” button; chip configuration file will be automatically recognized by ending *cfg.hex...
STM 300 is designed for multiple applications, therefore no application specific EnOcean Equipment Profile (EEP) is implemented. To use the auto learn function in DolphinView (or other EnOcean devices), the EEP profile must be configured first with DolphinStudio: Start Dolphin Studio and select „Chip configuration‟...
EDK 300 Getting Started DolphinView installation / presetting DolphinStudio has to be installed first, to get the required USB device driver. Launch DolphinView setup program and follow instructions Connect EOP 300 programmer to PC via USB cable and connect programmer to EVA 300 or EVA 320 Select COM port for serial interface “COM10 ...”...
3.8 Example ‘EVA 300 as Transceiver’ (Mode 1) EVA 300 configured as transceiver (Mode 1): Check jumper configuration and TCM 300 module according to the picture on the right side Connect EVA 300 via EOP 300 to Switch on EVA 300 board power DolphinView: Select COM port, ESP type and Connect button TCM 300...
Page 16
Now it‟s possible to set up manually the EEP* Profile in the tab EEP View, e.g. for the RPS telegram Subsequently the node button shows the label „EEP has been selected‟ The tab EEP View indicate the complete EEP profile details * EnOcean Equipment Profile Details see: http://www.enocean-alliance.org/ Page 16/24...
4 Self-powered Applications with EVA 320 and STM 300 4.1 Overview EOP 300 EVA 320 Board Programmer LED: Power EOP - Short term cap VCCUSB - Gold cap - Lithium accu (optional) LED: Power EVA Attention: VCCIO If EVA 320 + STM 300 stored ACCU ACCU for more then 2 weeks in darkness,...
EDK 300 Getting Started 4.2 Default Configuration Power Management: Power Switch (On/Off) Power Selector (USB/Solar/ExternalSolar/External) Storage Selector (Optional Accu/Goldcap /None) Connector for external power source Wake up & retransmit STM 300 standard Wake Up (1s/10s/100s/None) ...
4.3 Example: ‘Self-powered temperature sensor’ EVA 320 as temperature sensor, DolphinView to monitor radio with EVA300 as receiver: Set EVA 320 jumper configuration according to the image right side: - retransmit = every - wakeup = 10s - storage = GCAP - power source = solar - ADIO0 = NTC (temperature sensor) and DVDD = set...
Page 20
EDK 300 Getting Started Use EVA 300 in transceiver (gateway) mode to receive telegrams via DolphinView: Setup EVA 300 to USB transceiver (Mode1) Press the LRN button on the EVA 320 to teach-in the STM 300 in Dolphin- View automatically (on the basis of LRN telegram which includes the EEP no.)
4.4 Example: ‘Self-powered room operating panel’ EVA 320 as room operating panel and Dol- phinView to monitor radio with EVA 300 as receiver: Configure EVA 320: Set EVA 320 jumper configuration according to the image right side: - retransmit = Every STM 300 - wakeup= 10s - storage= GCAP...
Need help?
Do you have a question about the EDK 300 and is the answer not in the manual?
Questions and answers