  • Page 1 Anleitung – Durchfluss-Steuereinheit . . . . . . .A - 1 Instructions for Use – Flow Rate Control Unit . .B - 1 Guide d’utilisation – Unité de contrôle du débit . C - 1 TROTEC GmbH & Co. KG Grebbener Straße 7 D-52525 Heinsberg •...
  • Page 2: Table Of Contents

    Interesse einer laufenden Produktverbesserung sowie Form-/Farbverände- rungen bleiben vorbehalten. Lieferumfang kann von den Produktabbildungen ab- weichen. Das vorliegende Dokument wurde mit der gebotenen Sorgfalt erarbeitet. Wir übernehmen keinerlei Haftung für Fehler oder Auslassungen. © TROTEC ® 01. AllGemeIne BeSChReIBUnG...
  • Page 3: Vor Der Inbetriebnahme Lesen

    Behebung des Wasserschadens. schichttrocknung eingesetzt werden. Darüber hinaus Alle drei Kanäle der Durchfluss-Steuereinheit müssen ist das Gerät auf die Trotec MultiQube-Module VE 4, WA angeschlossen werden, da sonst die Funktion nicht 4,WA 4i, WA 6 und VE 6 speziell abgestimmt.
  • Page 4: Inbetriebnahme

    führt werden. Auf Baustellen darf die DA 4 nur gemäß Verwendung des Einschraubadapters in einen Ein- DIN VDE 100 über eine elektrische 1~230 V; 50 Hz; 16 gang des 4-Fachverteilers am Verdichter (Abb 2.). A Spannungsversorgung mit entsprechend vorgeschal- • Platzieren Sie den grauen Raumluftsensor in der Nähe tetem FI Schutzschalter (RCD) 30 mA angeschlossen des Kondensationstrockners.
  • Page 5 Kanäle ebenfalls wieder verschlossen sind. serschadensanierung geeignet. – Diese Zyklen werden solange wiederholt, bis der am Beachten Sie, dass der Trotec Verdichter VE 4 für ei- Verdichter platzierte und an der DA 4 angeschlossene nen Einsatz bis 40 m dimensioniert ist.
  • Page 6: Außerbetriebnahme

    Achten Sie auf mögliches Restwasser in den • Instandhaltungs- und Reparaturarbeiten sollten Schläuchen. nur durch Trotec ausgeführt werden. Wenn diese durch Dritte durchgeführt werden, erlischt die Ge- • Netzstecker ausstecken. währleistung und Haftung. trennen Sie vor Wartungs-, Pflege-, oder Re- •...
  • Page 7: Störungen Und Fehlerbeseitigung

    „Kein USB Stick enthalten“ onalität des Gerätes und stellen keinen Mangel dar. Durch Zufuhr von Heißluft, z. B. von einem • Prüfen Sie, ob der USB Stick aus USB Anschluss Fön, kann der Originalzustand wieder hergestellt der DA 4 entfernt wurde. werden. „Keine Verbindung zum USB Stick“ •...
  • Page 8 The scope of delivery may deviate from the product images. This docu- ment was created with due diligence. We do not assume any liability for errors or omissions. © TROTEC ® 01. GeneRAl DeSCRIPtIon...
  • Page 9: Read Before Commissioning

    Furthermore, the device is specifically aligned to the Trotec Multi-Qube modules The use of a flow rate control unit in explosion-risk VE 4, WA 4,WA 4i, WA 6 and VE 6.
  • Page 10: Commissioning

    In order to avoid faults, the device is to be cleaned at • Place the grey room air sensor near the condensa- regular intervals during or after each use, depending tion dryer. on individual loads. • Connect the device to the power supply. When using extension cables or cable drums, the ca- •...
  • Page 11 ≤ 55% humidity for ter damage. all three ducts. Please note that the Trotec VE 4 compressor is de- – In the final interval, the subsequent drying phase of signed for use up to 40m approx.
  • Page 12: Decommissioning

    Pay attention to possible residual water in the hoses. • Maintenance and repair work should only be per- formed by Trotec. If such work is performed by • Disconnect the power plug. third parties, the guarantee and liability become Before maintenance, service or repair work, void.
  • Page 13: Faults And Error Rectification

    “No USB flash drive” and is not a defect. By supplying hot air, e.g. by means of a blow dryer, the original status can be • Check whether the USB flash drive has been re- restored. moved from the USB port of the DA 4. •...
  • Page 14 Le contenu de la livraison peut différer des illustrations des produits. Le présent document a été établi avec le soin requis. Nous déclinons toute respon- sabilité pour les erreurs et les omissions. © TROTEC ® 01. DeSCRIPtIon GénéRAle 230 V L'unité...
  • Page 15: À Lire Avant La Mise En Service

    à l'utilisation avec les modules pas endommagée. Trotec MultiQube VE 4, WA4, WA 4i, WA 6 et VE 6. L'utilisation de l'unité de contrôle du débit dans les L'unité de contrôle du débit est conçue pour répartir de zones et atmosphères explosives n'est pas autorisée.
  • Page 16: Mise En Service

    100 sur un réseau avec une alimentation électrique presseur en le fixant avec l'adaptateur sur une 1~230 V ; 50 Hz ; 16 A protégé par un disjoncteur de entrée du répartiteur quadruple (Ill. 2). protection à courant de défaut RCD (FI), 30 mA. • Placez le capteur d'air ambiant près du séchoir à Pour éviter les dysfonctionnements, il est conseillé...
  • Page 17 à l'unité DA 4 émet un air Veuillez noter que le surpresseur VE 4 de Trotec est dont l'humidité est ≤ 55 % pour les trois canaux dimensionné pour une utilisation allant jusqu'à 40 m en même temps.
  • Page 18: Mise Hors Service

    • Retirez la fiche de la prise de courant. vent exclusivement être réalisés par la société Avant tous travaux de maintenance, d'entre- Trotec. Dans le cas contraire, la garantie n'est plus tien ou de réparation, toujours retirer la fiche en vigueur et nous déclinons toute responsabilité.
  • Page 19: Conseils En Cas De Problème

    « Aucune clé USB détectée » lorations blanches. Ce changement de couleur, qui ressemble à une fissure, n'a aucune influence sur le • Vérifiez si la clé USB a été retirée du port USB de fonctionnement de l'appareil et n'est pas un défaut. l'unité DA 4. De l'air chaud, par exemple avec un sèche-cheveux, permet de remettre le carter dans son état d'origine.
  • Page 20 TROTEC GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg ® Tel.: +49 2452 962 - 400 • Fax: +49 2452 962 - 200 www.trotec.de • E-Mail: info@trotec.de...