PROLITE - 41
MENU INTRODUCTION
Function
SpliceMode
System
History
SPLICE MODE MENU
SpliceMode
Fiber type
SM
Splice operate mode
Auto
Splice program No.
SM-1
Edit splice program
Clean Arc time
100 ms
Surface angle threshold
3.0 °
Fiber angle threshold
0.8 °
Align offset threshold
0.4 um
Loss threshold
0.10 dB
Compensation arc time
1.0 s
Fiber alignment mode
Core align
Fast splice mode
Off
FUNCTION SETTINGS MENU
Function
Sleeve heating mode
Enter
Fast ArcTest Mode
on
Tension test
on
Reset waiting time
12 s
Auto starting
on
Auto heating
on
100%
Enter
Maintain
Back
09-30
Help
09:30
14.11.2018
100%
Enter
Back
09:30
14.11.2018
Sleeve heating mode: Set the sleeve heating time.
100%
Fast ArcTest Mode:
Tension Test:
Enter
Reset Waiting
Time:
Back
Auto Starting:
09:30
Auto Heating:
14.11.2018
QUICK REFERENCE GUIDE
Function:
Set the parameters of some system functions such as heating
mode, arc compensation, reset time, etc.
Splice Mode:
Set the parameters of splice mode.
Maintain:
Electrode maintenance, arc correction, calibration, etc.
System:
Set the display parameters, system language & time, restore
to initial settings, etc.
History:
Record of number of arc times, splice results, etc.
Help:
Provide key operation manual.
Set according to the type of fibre used such as SM (single
Fiber type:
mode), MM (Multimode), DS (Dispersion shifted), NZDS (Non-
zero dispersion shifted). Each fibre type can have up to 30
fusion splice pre-set programs. Other available fibre types are
BIF (Bend Insensitive Fibre), UBIF (Ultra-Bend Insensitive
Fibre), EDF (Erbium Doped Fibre) and G.657B3 (Bend
Insensitive Single-Mode fibres).
Splice Operate
Automatic, Semi-automatic or Manual.
Mode:
Splice Program No.: 30 groups preset splice program and 80 groups of users-set
splice program.
Edit Splice
Edit splice parameters under the current number of program.
Program:
Clean Arc Time:
It cleans dust on the fiber surface by short-time arc. The
duration ranges from 0 to 200 ms.
An error message is displayed if the head face angle of either
Surface Angle
left or right side of fiber exceeds the angle threshold. The
Threshold:
setting range is 0-8°.
Fiber Angle
An error message is displayed if the clamp angle of the two
Threshold:
fibers spliced exceeds the angle threshold. The setting range
is
0-4°.
Align Offset
An error message is displayed if the misalignment of the two
Threshold:
fibers spliced exceeds the misalignment limit. The setting
range is 0.0-1.5 µm.
Loss Threshold:
An error message is displayed if the estimated splice loss
exceeds the loss limit. The setting range is 0-0.2db.
Compensation arc
Splice loss may be improved by compensative arc in some
Time:
cases.
Fiber Alignment
Cladding align or core align can be set.
Mode:
Fast Splice Mode:
If it is "on" it accelerates the alignment.
If this is set "on", after splice is completed, the equipment
adjusts arc current and tension test.
If this is set "on", after splice is completed, the equipment will
restore and Tension test will perform itself.
If the Tension test is set "off", the system will restore the
equipment after the waiting time is over.
If it is set "on", it will perform a splice itself when the cover is
closed.
If it is set "on", it starts heating when the cover is lid.