UPower UP-P22
User Guide
Feb. 2018 (v 0.7)
1 |
P a g e

Advertisement

loading
Need help?

Need help?

Do you have a question about the UPower UP-P22 and is the answer not in the manual?

Questions and answers

Summary of Contents for Onyx UPower UP-P22

  • Page 1 UPower UP-P22 User Guide Feb. 2018 (v 0.7) P a g e...
  • Page 2 ONYX Healthcare Inc., assumes no liabilities resulting from errors or omissions in this document, or from the use of the information contained herein ONYX Healthcare Inc. reserves the right to make changes in the product design without notice to its users P a g e...
  • Page 3 Onyx Healthcare EUROPE B.V. Ekkersrijt 4002, 5692 DA Son, The Netherlands TEL : +31-(0)499-462020 / FAX : +31-(0)499-462010 E-mail : eusales@onyx-healthcare.com / e-FAE@onyx-healthcare.com (Technical support) Onyx Healthcare Technology GmbH An der Trift65d 63303 Dreieich , Germany TEL : +49-(0)61033-7479-00 / FAX : +49-(0)61033-7479-49 E-mail : eusales@onyx-healthcare.com / e-FAE@onyx-healthcare.com (Technical support)
  • Page 4 Safety & Warranty WARNING: To avoid risk of electric shock, this equipment must only be connected to a supply mains with protective earth. WARNING: Do not modify this equipment without authorization of the manufacturer. Read these safety instructions carefully. Keep this user's manual for later reference. Disconnect this equipment from any AC outlet before cleaning.
  • Page 5 17. DO NOT LEAVE THIS EQUIPMENT IN AN UNCONTROLLED ENVIRONMENT WHERE THE STORAGE TEMPERATURE IS BELOW -20° C (-4° F) OR ABOVE 60° C (140° F). IT MAY DAMAGE THE EQUIPMENT. 18. External equipment intended for connection to signal input/output or other connectors, shall comply with relevant UL / IEC standard (e.g.
  • Page 6 This device complies with Part 18 FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received including interference that may cause undesired operation. UL Module Description UPower Pro-22 modules are developed to suitable for the Classification Mark...
  • Page 7 INSTRUCTIONS FOR USING THE BATTERIES IN UPOWER The UPower batteries are based on LI-ION Technology. A feature of this technology is that if the batteries are discharged until a certain point, they cannot be recharged again and internally the battery is destroyed. This is inherent of the LI-ION technology. In order to avoid that UPower batteries are not chargeable anymore we advise to use the UPower batteries as follows.
  • Page 8: Table Of Contents

    Contents Component identification………………………………………………………………………………………………9 Specification……………………………………………………………………………………………………………………10 Installation and Operation………………………………………………………………………………………………11 Cleaning…………………………………………………………………………………………………………………………14 Scrap Unit Recycling………………………………………………………………………………………………………16 P a g e...
  • Page 9: Component Identification

    Component Identification Battery LED indicator LED status What does it means Blue Lighting Adaptor output @AC mode Blue Flashing Charging (@AC mode) Green Lighting Capacity 16%~100% @Battery mode Orange Lighting Capacity 8%~15% @Battery mode Purple Lighting Capacity 0%~7% @Battery mode Green-Purple Flashing Error Micro USB...
  • Page 10: Specification

    Specification Main Specification Output Voltage 12/19/24V (can be selected only one voltage) mini-din 4pin : MAX 100W @24V with XL Battery* MAX 90W @12V/19V with XL Battery** MAX 50W @12V/19V/24V with standard battery*** Output Capacity USB Type A : MAX 10W ** (power output only) * total power output (mini-din+USB) MUST lower than 100W@24V with XL battery ** total power output (mini-din+USB) MUST lower than 90W@12V/19V with XL battery *** total power output (mini-din+USB) MUST lower than 50W with standard battery...
  • Page 11 Battery Specification Model GLW OPM-P01T GLW OPM-P02T Rating 10.8V, 5700mAh, 61.56Wh 10.95V, 8550mAh, 93.62Wh Power Supply Specification Model EDAC EM11701F EDAC EM11011M Input Voltage 100-240V AC @50-60 Hz 100-240V AC @50-60 Hz Output Power 24V / 6.25A, 150W max 24V / 5A, 120W max 11 | P a g e...
  • Page 12: Installation And Operation

    The installation and service of this product must be performed by individuals who are knowledgeable about the procedures and precautions. WARNING: The charger is restricted to charging ONYX batteries only. Never use this charger for other batteries. WARNING: The charging unit should only be used at normal indoor room conditions.
  • Page 13 How to Setup your UPower: 1. To lock the M3 screw to hold the mounting bracket in UPower 2. To lock the M3 screw to hold the UPower in a well-ventilated place How to Power the Equipment: Your equipment 1. Removed all the batteries, USB cable and adaptor from the UPower. 2.
  • Page 14 6. Insert the full charge batteries. (UPower would directly provide the power when inserting the battery) 7. Turn on your equipment. 8. If the battery power is low, replace to the full charge battery. (UPower would lose the power when user remove both batteries at the same time) # total power output (mini-din+USB) MUST lower than 100W@24V with XL battery;...
  • Page 15 3. The LED indicator will show blue light when full charging # the charging current will be auto-regulated (0A~4A) by the UP-P22 depending on the battery temperature or remaining adaptor power How to switch the voltage: 1. Turn off and removed the equipment from UPower 2.
  • Page 16: Cleaning

    Cleaning General Cleaning Tips You may need the following precautions before you begin to clean the computer. When you clean any single part or component for the computer, please read and understand the details below fully. 1. Never spray or squirt the liquids directly onto any computer component. If you need to clean the device, please rub it with a piece of dry cloth.
  • Page 17: Scrap Unit Recycling

    For the computers that are no longer useful or work well, please contact with worldwide distributors for recycling. The worldwide distributors show on the following website: http://www.onyx-healthcare.com.tw/Contact.php Note: Computer and battery pack should follow the national requirement to dispose unit...