  • Page 1 U S E R M ANUA L...
  • Page 2: Table Of Contents

    About ......................3 Contents ...................... 4 Function of RF Device ................6 Mode 1 (Red LED + RF) ................7 Mode 2 (Purple LED + EMS) ..............9 Mode 3 (Blue LED + Cooling) ..............10 Before You Begin ..................11 Lifetime Warranty ...................12...
  • Page 3: About

    Radio Frequency Regimen is a multi- step routine that enhances skin texture and reduces the appearance of fine lines, breakouts and inflammation. The RF Regimen has three modes to enhance your skincare experience. Mode 1: Radio frequency (RF) and red LED stimulate collagen production and cellular activity, to help reduce the appearance of wrinkles,scars, and promote firmer, tighter skin.
  • Page 4: Contents

    C ONT EN TS RF Device Charging Port & Adapter Duo Component: 2 formulations, 1- Vibrant Renewal Cream 2- Advanced Facial Treatment Serum Radiance Reinforcing Powder (12 bottles) Silicone Device Cover Cleaning cloth Travel Pouch 4 | RF REGIMEN MANUAL...
  • Page 5 Treatment Surface Indicator Lights Mode Selector Button On/ Off Button Charging Port Socket Adapter DC Plug DC Pin Charging Port RF REGIMEN MANUAL | 5...
  • Page 6: Function Of Rf Device

    F UN C T I ON S O F TH E R F DEVI CE Mode 1: Red LED lights + Radio Frequency (RF) Mode 2: Purple LED lights + Electrical Muscle Stimulation (EMS) Mode 3: Blue LED Lights + Cooling Feature ON MODE 3 ONLY: After 5 minutes, Blue LEDs will automatically shut off.
  • Page 7: Mode 1 (Red Led + Rf)

    ‘reshapes’ and ‘re-contours’ the skin from its deeper layers. The treatment involves using RF electrodes to deliver radio frequency waves into the skin, warming up tissue and triggering an increased production of collagen and elastin, which in turn tightens loose skin and smooths wrinkles.
  • Page 8 DEL IVERY OF RF ENE R GY Non-ablative, sub-necrotic gentle dermal heating external electrode Flow of RF Energy 8 | RF REGIMEN MANUAL...
  • Page 9: Mode 2 (Purple Led + Ems)

    Thanks to the way purple LED stimulates collagen production, neutralizes acne-causing bacteria, and promotes oxygen supply to the skin, it is able to RF REGIMEN MANUAL | 9...
  • Page 10: Mode 3 (Blue Led + Cooling)

    COOLING FEATURE After using your device on RF mode, the effect of the stainless steel chillers cool down and calm your skin, reduce inflammation and redness, and tighten your pores to conclude the treatment.
  • Page 11: Before You Begin

    Before using your RF DEVICE for the first time, charge the battery to full. This may take up to 6 hours. Please note that you cannot use your RF DEVICE while it is charging. (Refer to section “Charging Your Device”).
  • Page 12: Lifetime Warranty

    100% Manufacturer Satisfaction Guarantee and will permit an exchange of the purchased product for any alternative Jelessi product of equal or lesser value. For any questions feel free to contact cservice@jelessi.com. 12 | RF REGIMEN MANUAL...
  • Page 13: Researched By Nasa

    (1) NASA WEBSITE - TECHNOLOGIES LED TREATMENT (2) NASA WEBSITE - NASA Light Technology The RF Regimen device has been tested and approved by a certified MD. The assessment concludes the RF Regimen device as safe and efficient for the purposes of anti-aging treatment.
  • Page 14: Light Indicators

    LI GHT IND ICAT OR S Steady Red: Device is powered on Mode 1 (Red LED + RF) Steady Purple: Device is powered on Mode 2 (Purple LED + EMS) Steady Blue: Device is powered on Mode 3 (Blue LED + Cooling) Rapid Yellow Flashing: Device needs to be charged.
  • Page 15: Treatment How To/Directions

    T R E A T M EN T H O W TO /DIR ECT I ON S Please note the RF Regimen device has an inactivity timer that will automatically turn the device off if it has not been in contact with the skin or in use for 10 minutes during Mode 1 (Red LED Lights + Radio Frequency) &...
  • Page 16 You may feel slight tightening — this is from the EMS function, stimulating and contracting your muscles. *Step 7 (optional): Apply the “Advanced Facial Treatment Serum” MODE 3 (Blue LED + Cooling) to your desired facial treatment areas (avoid eyes). 16 | RF REGIMEN MANUAL...
  • Page 17 MODE 2. If the device is off, push the POWER button, and the function key THREE TIMES). This initiates MODE 3 (Blue LED + Cooling) on your RF DEVICE. For three minutes, apply a light pressure while slowly moving the applicator in small, circular motions on your desired treatment areas.
  • Page 18: Treatment Areas

    T REAT MENT AR EAS FACE FOREHEAD AROUND EYES DO NOT use the device on eyelids. Be sure not to over-treat, and to follow the treatment regimen, as over-treating can lead to redness and swelling. 18 | RF REGIMEN MANUAL...
  • Page 19: What To Expect During Treatment

    During a session, it is normal to experience and/or feel: • A sensation of warmth, vibrating, or slightly invasive feeling during EMS and RF functions. You will also feel cooling during the Blue LED/Cooling function. This is normal and should disappear within an hour after the session.
  • Page 20: Potential Effects After Treatment

    • Minor skin discomfort: Your skin may become slightly irritated after using RF Regimen device. This should disappear within 24-48 hours after treatment. • Skin redness: Your skin may become slightly red right after using RF Regimen device.
  • Page 21: Important Safety Information

    Do not use this device on areas of potential skin cancer such as dark brown or black spots, large freckles, birthmarks, moles or warts. To do so may result in delaying the best medical treatment. RF REGIMEN MANUAL | 21...
  • Page 22 CAUSE SERIOUS INJURY OR DEATH • Do not place in, or drop into water or any other liquid. • Do not use RF Regimen device if it becomes damp or wet. • Do not attempt to open or repair your RF Regimen device. •...
  • Page 23: Safety Features Of The Rf Regimen

    RF Regimen device has an automatic inactivity shut-off feature. • The RF Regimen device has an inactivity timer that will automatically turn the device off if it has not been in contact with the skin or in use for 10 minutes during Mode 1 (Red LED Lights + Radio Frequency) &...
  • Page 24: Charging Your Device

    C A U T I O N ! Never use any power supply other than the one provided with your device. If you lose the power unit or it is damaged, contact the manufacturer for a new one. 24 | RF REGIMEN MANUAL...
  • Page 25: Maintenance Of Your Device

    S T O R A G E Store the clean device and all its parts in a cool dry place. • Do not place or store RF Regimen device where it can fall or be pushed into a tub, sink or any other vessel containing water.
  • Page 26: Troubleshooting

    If the applicator still does not charge, contact customer service. The applicator is broken. Contact customer service. Applicator temperature rises This is normal. No action is required. during use. 26 | RF REGIMEN MANUAL...
  • Page 27: Device Specifications

    Blue LED: 6 pcs, 465mm Charging Test Power: 0.7-4.7W Rated Voltage: 100V/240V; 50/60Hz 0.3A Lithium Battery Voltage & Current: 7.4V, 800mAh Charging Voltage and Current: 10.5V-0.4mA (DC Charging) Product Size: Length (198mm) x Width (45mm) x Height (59.6mm) RF REGIMEN MANUAL | 27...
  • Page 28: Labeling

    LABELING Degree of protection against electric shock : type BF applied part. WEEE- Waste Electrical and Electronic Equipment Follow the instructions for use IP22 Waterproof IP rating Keep Dry 28 | RF REGIMEN MANUAL...