Do you have a question about the Ignis 5I and is the answer not in the manual?
Questions and answers
Summary of Contents for Valiant Ignis 5I
Page 1
FIR913 IGNIS 5I Wood & Multi Fuel Cassette Inset Stove DEFRA Approved Instructions for Use, Installation & Servicing...
Page 2
FIR913 Valiant Ignis 5i Technical Specification EN13229:2001 + EN13229-A2:2004 Parameter - Tested on wood Valiant 5i (5kW) Test Duration Total Efficiency 82.7 Nominal Heat Output Nominal Heat Output to Space Mean CO emission (at 13%O2 ) Mean flue gas temperature ºC...
Appliance Commissioning Checklist Purchase Record Name of retailer: Address: Telephone no: Date of purchase: Product Record Valiant model name: Product serial number: Date installed: Address of install: Installation Record Company name: Address: Telephone number: Name of installer: Date installed: Commissioning Checklist – to be completed & signed by the installer:...
We recommend that you understand these instructions to enable safe, easy use a Valiant Moisture Meter to test and ensure and effective use of your Valiant Ignis stove. that wood fuel contains less than 20% moisture content.
• Place fire lighters or loose paper in the grate and use a Valiant Moisture Meter to test and ensure put dry kindling on top. that wood fuel contains less than 20% moisture content. • Light the fire lighters or paper.
• Lightly oil the door catch mechanism and hinge pins - avoiding glass and rope seals. Guarantee • Your Valiant multifuel stove is guaranteed for a period of 2 years against faulty materials and workmanship, subject to the stove being installed by a recognised qualified installer and registered to Valiant.
Troubleshooting Tips Issue Cause Solution Creosote build-up in Burning wet wood Use dry seasoned wood (less the chimney (over 20% moisture than 20% moisture content). content) Operating the appliance at a high temperature for a short period of time each time it is used will avoid the build-up of tar and creosote Tar around flue joints...
Page 8
These instructions cover the basic instructions All Valiant stoves must be flued into the chimney to ensure the satisfactory installation of the using a minimum 130 diameter pipe and sealed appliance, although details may need slight into the flue liner using a clay pot adaptor.
Air Supply Distances to combustibles may be reduced if a suitable heatshield or insulation is fitted in All stoves require adequate fresh air for efficient accordance with building regulations. and safe combustion. It is essential that an appropriate sized air supply is permanently Constructional Hearth provided, as close to the appliance as possible to reduce unpleasant draughts and enable the stove...
Page 10
Installation • The appliance is factory supplied with a top flue outlet, connection to the chimney or • Remove all packaging and transport fasteners, flue liner must be made using a vitreous or remove fire bricks and baffles. stainless steel flue pipe of the same diameter •...
• Record the appliance’s serial number in Appliance Commissioning Checklist. • Give this instruction manual to the customer to keep in a safe place. Replacement Parts Only genuine replacement Valiant parts may be used in this appliance. Contact your local dealer for details.
Need help?
Do you have a question about the Ignis 5I and is the answer not in the manual?
Questions and answers