SC iCare 110 | 140 – Protective Functions
Short-circuit protection
1� If a short circuit should present itself before using the device, the LED light will flash rapidly 3 times
before the short circuit occurs and the device will switch off automatically�
2� If a short circuit should occur while the device is in use, the LED light will flash slowly 3 times�
Atomizer head protection
The device will switch off automatically if the activation button is pressed down for longer than 10
seconds� The LED light will flash 8 times to indicate this process�
Low voltage protection
If the battery voltage should fall below 3�3V, then LED indicator will flash 10 times and the device will
switch off� Connect the device to a compatible power supply to charge it�
Resistance detection
If the device's resistance is below 1 ohm, it will switch off automatically as soon as you press the
activation button�