EFOY-MASTERVOLT CABLE
SCHEME
English
1.
Mastervolt MLi Ultra battery or
GEL battery with MasterShunt
2.
Fuse in positive battery cable
3.
MasterBus cable
4.
Multipurpose contact
5.
EFOY-MASTERVOLT cable
6.
EFOY fuel cell
7.
Loads
8.
Positive DC line
9.
Minus DC line
10.
MasterBus cable
11.
MasterBus terminator
12.
Fuse in positive cable
13.
Optional: Battery Safety relay
only in combination with MLI
Ultra battery. Refer to the MLi
Ultra manual.
Figure 2: Installation scheme of the EFOY-MASTERVOLT cable, this is not a complete system
MASTERBUS SETTINGS
MasterBus settings must be done on the Multipurpose Contact output (MPC) and the MasterShunt (for Gel batteries) or the MLi Ultra batteries.
For the Masterbus settings we refer to the Mastershunt (for Gel batteries) or the MLI Ultra battery user manual.
The percentages below are recommended values for the use of the EFOY fuel cell in combination with MASTERVOLT batteries.
Multipurpose contact settings
Device name
1 second pulse option
Alarm setpoints
Battery pre low
Battery low
Battery full
Events for Gel (MasterShunt) or MLi Ultra batteries
Event Source
Battery pre low
Battery low (for Gel batteries)
Battery low (for MLi Ultra batteries)
Battery full
Safety events for MLi Ultra battery
Event Source
Stop charge
Battery safety
Stop charge (on charger or Mass Combi)
Battery settings for MLi Ultra
MasterBus power
EFOY FUEL CELL SETTINGS
Figure 3: EFOY fuel cell settings
SPECIFICATIONS
Model
Applicable for MASTERVOLT Gel batteries
Applicable for MASTERVOLT Li-ion batteries
Applicable for EFOY fuel cells
Cable length
Connectivity
Mastervolt International B.V.
P.O.Box 22947, NL-1100 DK Amsterdam, The Netherlands.
SFC Energy AG
, Eugen-Sänger-Ring 7, D-85635 Brunnthal-Nord, Germany.
Nederlands
Deutsch
Mastervolt MLi Ultra accu of
Mastervolt MLi Ultra Batterie oder
GEL accu met MasterShunt.
GEL-Batterie mit MasterShunt
Zekering in pluskabel
Sicherung in Pluskabel
MasterBus kabel
MasterBus kabel
Multipurpose contact
Multipurpose contact
EFOY-MASTERVOLT kabel
EFOY-MASTERVOLT kabel
EFOY brandstofcel
EFOY Brennstoffzelle
Lasten
Lasten
DC Pluskabel
DC Pluskabel
DC Minuskabel
DC Minuskabel
MasterBus kabel
MasterBuskabel
MasterBus terminator
MasterBusterminator
Zekering in pluskabel
Sicherung in Pluskabel
Optioneel: Battery Safety
Optional: Batterie Sicherheitsrelais
relais, alleen in combinatie
nur in Kombination mit MLI Ultra-
met de MLi Ultra accu. Zie de
Batterie. Siehe Bedienungs-
MLi Ultra handleiding.
anleitung MLi Ultra.
MPC Fuel cell
On (checked)
MasterShunt (for Gel battery up to 200Ah)
50%
(fuel cell is switched On)
40%
(inverter is switched Off)
80%
(100 % by battery charger only)
Event Target
MPC Fuel cell
Mass Combi
MLi Ultra
MPC Fuel cell
Event Target
MPC Fuel cell
MPC Fuel cell
device dependent
Off (unchecked)
1. Select the External control mode
• Press
on the operating panel, or select "Operating mode" in the main menu. The operating mode selection appears.
• Select the "External control on" operating mode.
• Press [ok] to confirm your selection.
• If the EFOY-MASTERVOLT cable is correctly connected to the EFOY fuel cell, the infoscreen will show "Hybrid" and an open padlock.
• If the EFOY fuel cell is activated via the EFOY-MASTERVOLT cable, "RC" will be displayed on the Infoscreen
2. Choose the battery type in the expert menu
• To access the expert menu, press and hold [ok] and [menu] at the same time for two seconds. The expert menu appears.
• Press
[][
] to select a submenu.
• Choose the submenu "Battery type" and press OK.
• Choose the battery type "Gel" for the Gel batteries or "LiFePo4" for the MLi Ultra batteries
Note: The standard factory settings correspond to lead-acid batteries.
For all settings and language versions, please refer to the standard EFOY user manual
77032100 EFOY-MASTERVOLT Cable
12V GEL batteries up to 12V-200Ah
MLi Ultra 12/2500, MLi Ultra 12/5000
EFOY COMFORT 140 and 210, EFOY Pro 2400, 2400 Duo
1500 mm including the connectors
Multipurpose contact (article nr 77030500 not included)
Tel: +49 89 673 592 555
SCHEME / SETTINGS / SPECIFICATIONS
MLi 12/2500 or MLi12/5000
40%
(fuel cell is switched On)
20%
(battery is disconnected)
90%
(to avoid triggering stop charge event)
Event Command
Activate
Inverter
Open relay
Activate
Event Command
Activate
Activate
Charger On
Tel.:
+31-20-3422100
Email: info@mastervolt.com
Email: service@sfc.com
Web: www.sfc.com
Event Data
On
Off
On
Off
Event Data
Off
Off
Copy invert
Web: www.mastervolt.com