Ecom Ex 171-0 Operating Instructions Manual

Intrinsically safe data loggers for temperature and relative humidity

Advertisement

Quick Links

Bedienungsanleitung
Operating Instructions
Notice d'utilisation
Gebruiksaanwijzing
Explosionsgeschützter Datenlogger
für Temperatur und relative Feuchte.
Intrinsically Safe Data Loggers for Temperature
and Relative Humidity
Enregistreur de température et d'humidité pour
zones à risques d'explosion
Explosieveilige datalogger voor temperatuur en
relatieve vochtigheid
Ex 171-0 [°C]
Ex 171-3 [°C; %rF]
Ex 171-0 [°C]
Ex 171-3 [°C; % rH]

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ex 171-0 and is the answer not in the manual?

Questions and answers

Summary of Contents for Ecom Ex 171-0

  • Page 1 Intrinsically Safe Data Loggers for Temperature and Relative Humidity Enregistreur de température et d'humidité pour zones à risques d'explosion Explosieveilige datalogger voor temperatuur en relatieve vochtigheid Ex 171-0 [°C] Ex 171-3 [°C; %rF] Ex 171-0 [°C] Ex 171-3 [°C; % rH]...
  • Page 2 List of Contents Page 1. Safety advice 2. Faults and damage 3. Safety regulations 4. Technical safety advice 5. Data transmission 6. Battery change 7. Regular inspection and maintenance 8. Repair 9. Guarantee 10. Liability 11. Applications in Ex areas 12.
  • Page 3 1. Safety Advice 5. Data Transmission The following operating instructions contain information and precautionary The interface connection and the data transmission can only be advice which for the described conditions, must be taken into consideration carried out with an accompanying interface. to guarantee safe operation.
  • Page 4 11. Applications in Ex-Areas The data loggers Ex 171-0 and Ex 171-3 measure and store up to 55,000 measurements and have a battery life of up to four years. Applications in hazardous areas of - for example - the chemical and pharmaceutical indu- stry, are in the monitoring of the atmosphere, especially the documentation of atmospheric facts, temperature [°C] and relative...
  • Page 5 13. Technical Data: Ex 171-0 Ex 171-3 Measurement Temp. [°C] Temp. [°C] & Relative humidity [%rH] Temperature Range -35°C … +70°C -10°C … +50°C Resolution 0,1°C 0,1°C Accuracy ±0,5°C ≤ -40°C (± 1 digit) ±0,4°C ±0,6°C > +40°C Humidity 0 … 100%rH...
  • Page 6 ECOM Rolf Nied GmbH Industriestr.2 D-97959 Assamstadt Tel.: +49 (0) 62 94/42 24 0 Fax: +49 (0) 62 94/42 24 90 E-Mail: sales@ecom-ex.com Internet: www.ecom-ex.com...

This manual is also suitable for:

Ex 171-3

Table of Contents