Table of Contents

Advertisement

Quick Links

CLOCK77/PCI
CLOCK77/USB
CLOCK77/ISA
© QUANCOM Informationssysteme GmbH

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CLOCK77/PCI and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Quancom CLOCK77/PCI

  • Page 1 CLOCK77/PCI CLOCK77/USB CLOCK77/ISA © QUANCOM Informationssysteme GmbH...
  • Page 2 All specification in this manual was arranged after careful check, and it is not considered as any warranty of product properties. QUANCOM shall not be responsible for any errors or omissions contained in this user’s manual, and reserves the right to make changes without notice. Passing on and duplication of this manual and the utilisation of its contents as well as the software belonging to the product are permitted only with written permission by QUANCOM.
  • Page 3: Table Of Contents

    ................................19 JP1: Address jumper for I/O connection in the PC ................................20 D-Sub 9 socket of CLOCK77/ISA, CLOCK77/PCI ................................20 ChapterIV Installing drivers and software for the QUANCOM CLOCK77 21 Installing the CLOCK77/USB ............................21 Installing the CLOCK77/PCI ............................23 © QUANCOM Informationssysteme GmbH...
  • Page 4 Inhalt Installing the CLOCK77/ISA ............................25 Installing the CLOCK77/PCI for Windows NT 4 ............................27 Installing the CLOCK77/ISA for Windows NT 4 ............................28 ChapterV Software Antenna adjustment for the reception of time signals ............................29 The monitor program (only Microsoft Windows) ............................30 ChapterVI The Windows 3.1x / DOS Programm Switch for the DOS program CLOCK77.EXE...
  • Page 5: Chapteri Overview

    At our design centres QUANCOM has developed an impressive range of products. Customer Communication QUANCOM wants to receive your comments on our products and manuals. We are also interested in the applications you developed with our products, and we want to help if you have problems with them.
  • Page 6 Overview · Driver/ Software for the various operating systems · Manual If a component is missing please contact your dealer. QUANCOM reserves the right to change the extent of delivery without a preliminary announcement. © QUANCOM Informationssysteme GmbH...
  • Page 7: Chapterii Installation Procedures

    In chapter “Technical hardware description” you’ll find more informations about the System requirements. Safety precautions For the sake of your security and the faultless function of your new QUANCOM board mind the following advice: · Before opening the computer please unplug it.
  • Page 8: Installation Of The Dcf-Clock Interface Board

    5. Fasten the board with the screw of the small metal plate on the back wall. 6. Close the cover of your computer. Cables, that you detached during the installation, should now be reconnected. 7. Connect the cable of the board into the slot belonging to it. © QUANCOM Informationssysteme GmbH...
  • Page 9: Connecting The Usb- Module

    CLOCK77/PCI CLOCK77/USB CLOCK77/ISA Connecting the USB- Module Switch on the PC and start Windows. Install the driver as shown in chapter “ Installing the CLOCK77/USB for Windows XP/2000 Installing the CLOCK77/USB for Windows ” or ” ME/98 and after that you safely can connect the USB-Module to the PC. If you do otherwise, Windows won’t find the drivers and the module won’t work properly.
  • Page 10: Chapteriii Technical Hardware Description

    USB-connector. All necessary signals and power supply for the module are supplied by the interface. The cable of the CLOCK77/PCI + CLOCK77/ISA of receiver can be extended on up to 20m. For distances more largely we offer an additional CLOCK AMPLIFIER , with which you can attach the receiver up to 100m far away from the CLOCK77 to 20m.
  • Page 11: How The Clock77 Works

    CLOCK77/PCI CLOCK77/USB CLOCK77/ISA source-code shows the access to the Interface and the CLOCK77. (Except for CLOCK77/USB which is only supported by Windows XP / 2000 / ME / 98) How the CLOCK77 works After calling up the software CLOCK77, the antenna system receives signals from the transmitter in Mainflingen.
  • Page 12: Clock77/Pci-Express

    Technical hardware description CLOCK77/PCI-Express 3.4.1 Board overview © QUANCOM Informationssysteme GmbH...
  • Page 13: Connector Of The Clock77/Pci-Express

    CLOCK77/PCI CLOCK77/USB CLOCK77/ISA 3.4.2 Connector of the CLOCK77/PCI-Express 3.4.3 LED Description The LED 1 ( Configuration LED ) lights until the PCI Express interface is configured. This happens at the start, until reset the computer or by the operating system.
  • Page 14: Clock77/Pci (Rev. 4.X)

    Technical hardware description CLOCK77/PCI (Rev. 4.x) 3.5.1 Board overview © QUANCOM Informationssysteme GmbH...
  • Page 15: Connector To The Clock77 Receiver-Module

    CLOCK77/PCI CLOCK77/USB CLOCK77/ISA 3.5.2 Connector to the CLOCK77 receiver-module © QUANCOM Informationssysteme GmbH...
  • Page 16: Led Description

    3.5.3 LED Description Die LED 1 ( Konfigurations- LED ) lights until the Clock77/PCI interface is configured. This happens at the start, until reset the computer or by the operating system. Die LED 2 ( Access LED ) flashes briefly when requests (such as reading, writing) to the CLOCK77/PCI Card .
  • Page 17: Clock77/Usb

    CLOCK77/PCI CLOCK77/USB CLOCK77/ISA CLOCK77/USB 3.6.1 USB Receiver Module © QUANCOM Informationssysteme GmbH...
  • Page 18: Clock77/Pci (Rev. 3.X)

    CLOCK77/PCI (Rev. 3.x) Available since May 2003. The card is comparable with the clock 77 PCI ( Rev.2.x ) The attitude between 3,3V and 5V operating voltage is new. It was replaced in the meantime by the CLOCK77/PCI (Rev.4.x.). 3.7.1 Board overview...
  • Page 19: Connector To The Clock77 Receiver-Module

    CLOCK77/PCI CLOCK77/USB CLOCK77/ISA 3.7.2 Connector to the CLOCK77 receiver-module 3.7.3 Jumper settings for cards power supply Semple Jumper settings for 5V power supply Semple Jumper settings for 3,3V power supply © QUANCOM Informationssysteme GmbH...
  • Page 20: Led Description

    3.7.4 LED Description Die LED 1 ( Konfigurations- LED ) lights until the Clock77/PCI interface is configured. This happens at the start, until reset the computer or by the operating system. Die LED 2 ( Access LED ) flashes briefly when requests (such as reading, writing) to the CLOCK77/PCI Card .
  • Page 21: Clock77/Pci Card (Rev. 2.X)

    CLOCK77/PCI CLOCK77/USB CLOCK77/ISA CLOCK77/PCI Card (Rev. 2.x) This version of the interface map became in May 2003 by the Rev. 3.x replaces. 3.8.1 Board overview © QUANCOM Informationssysteme GmbH...
  • Page 22: Connector To The Clock77 Receiver-Module

    Technical hardware description 3.8.2 Connector to the CLOCK77 receiver-module © QUANCOM Informationssysteme GmbH...
  • Page 23: Clock77/Isa Card

    CLOCK77/PCI CLOCK77/USB CLOCK77/ISA CLOCK77/ISA Card 3.9.1 Board overview © QUANCOM Informationssysteme GmbH...
  • Page 24: Jp1: Address Jumper For I/O Connection In The Pc

    Technical hardware description 3.9.2 JP1: Address jumper for I/O connection in the PC 3.9.3 D-Sub 9 socket of CLOCK77/ISA, CLOCK77/PCI © QUANCOM Informationssysteme GmbH...
  • Page 25: Chapteriv Installing Drivers And Software For The Quancom Clock77

    1. Step: Software Installation Insert the QUANCOM Installation- CD into the CD-ROM. It is important that you connect the USB-module after the software installation. · Click on ” Start | Run ”, and choose CLK77D.EXE from the WIN-XP-2000 folder of the Installations-CD and click on “OK”.
  • Page 26 Installing drivers and software for the QUANCOM CLOCK77 · After the files were copied and the drivers registered, the installation will be closed with “ Finish”. · You now may connect the CLOCK77/USB to a free USB- connector and reboot your system to ensure that all drivers are loaded properly.
  • Page 27: Installing The Clock77/Pci

    · In the next window you have to confirm with ”Next” that you want to install the driver. · In the following window you finish the installation of the QUANCOM driver with a click on the button ”Finish”. 1. Step: Software Installation: After installation of the drivers for the interface board, the CLOCK77 Software has to be installed.
  • Page 28 · You can choose the destination path of the CLOCK77-Software with “Browse”. Click on “ Next” to accept your decision. · Now you choose the model of your clock: CLOCK77/PCI and go on with “Next”. · The installation-process will be started with “Next”.
  • Page 29: Installing The Clock77/Isa

    CLOCK77/PCI CLOCK77/USB CLOCK77/ISA Installing the CLOCK77/ISA The installation of the drivers has to be done with the rights of the system-administrator. If you don’t own such rights, contact your system administrator. 1. Step : installation of the drivers: To install the drivers of the ISA-card insert the Clock-Installation- CD into your CD-ROM-drive and click on ”...
  • Page 30 Installing drivers and software for the QUANCOM CLOCK77 After installation of the drivers for the interface board, the CLOCK77 Software has to be installed. · Click on Start | Run , and choose CLK77D.EXE from the WIN-XP-2000 folder of the Installations-CD and click on “OK”.
  • Page 31: Installing The Clock77/Pci For Windows Nt

    CLOCK77/PCI CLOCK77/USB CLOCK77/ISA Installing the CLOCK77/PCI for Windows NT 4 The installation of the drivers has to be done with the rights of the system-administrator. If you don’t own such rights, contact your system administrator. 1. Step: Software Installation: After you inserted the interface board into the PC, the CLOCK77 Software has to be installed.
  • Page 32: Installing The Clock77/Isa For Windows Nt 4

    Installing drivers and software for the QUANCOM CLOCK77 Installing the CLOCK77/ISA for Windows NT 4 The installation of the drivers has to be done with the rights of the system-administrator. If you don’t own such rights, contact your system administrator.
  • Page 33: Chapterv Software

    Software Antenna adjustment for the reception of time signals So that the CLOCK77/USB , CLOCK77/PCI or CLOCK77/ISA card can receive a time signal to be analysed, the antenna must be properly aligned. Please start the CLOCK77 monitor program. This program displays the arriving signals as lines.
  • Page 34: The Monitor Program (Only Microsoft Windows)

    Software The monitor program (only Microsoft Windows) With the delivery of the QUANCOM CLOCK77 USB/PCI/ISA card you will get a special monitor program. This program is able to show whether the reception is good or bad. If the signal reception is bad, you will see red lines on your monitor program and if it is good, you will see green lines.
  • Page 35: Chaptervi The Windows 3.1X / Dos Programm

    CLOCK77/PCI CLOCK77/USB CLOCK77/ISA The Windows 3.1x / DOS Programm For DOS and Windows 3.1 the time will be adjusted by a Software-interrupt driven background-task. The program is located in the DOS folder of the Installation-CD. To start the program with every system-start-up, you have to copy the file to any folder on your harddisk and call it from with the AUTOEXEC.BAT with the proper switches.
  • Page 36: Switch For The Dos Program Clock77.Exe

    100 and 3FF /pxxx (default.: xxx=1D0) LPT1: 378 with Herkules- graphics-card: LPT1: LPT2: 278 searches for the CLOCK77/PCI Set offset for received time in hours (positive numbers add xx hours) and Allowed values: -12 ... 12 /txx (negative numbers subtracts xx Date is adjusted if needed hours).
  • Page 37: Chaptervii Annex

    CLOCK77/PCI CLOCK77/USB CLOCK77/ISA Annex When is the time set? The time is sequentially received (minütlich). If disturbances arise, e.g. to spikes, invalid telegrams are rejected. The time three times correctly received (plausibility check, parity, etc.) is intended the relative deviation of the telegrams for the system time. If these three telegrams do not deviate by any longer than +/-200ms from each other, then the three times are recognized as correct.
  • Page 38: Id' S In The Event Announcement Under Windows Xp/2000/Nt

    Open the diagnostic and attitude program “CLOCK77.EXE”, by clicking down right in the task border on the antenna symbol. Select “monitor program”. In the monitor you go please into the menu “attitudes”/“event announcement”. Switch all entries off up to “error messages”. © QUANCOM Informationssysteme GmbH...
  • Page 39: Windows Xp/2000/Nt: Error Message No.: 2140

    7.1.6 Windows XP/2000/NT: Error message No.: 2140 Windows XP/2000/NT: Error message No.: 2140 when starting of the service “QUANCOM CLOCK77” in the XP/2000/NT service manager. The error message arises, if the monitor program is active in the task border. The service started causes an error now.
  • Page 40: Possible Problems Under Dos

    Annex data in such a situation. 7.1.9 Possible problems under DOS Can I use a Memory-Manager ? (QEMM 386, EMM386) It is possible to use a Memory-Manager, but the performance maybe decrease. © QUANCOM Informationssysteme GmbH...
  • Page 41: Customer Communication And Help

    Customer Communication and Help Did you need help? If you don’t know how to go on during the installation or operation of your QUANCOM board please consult this user’s guide first. ! Tip ! You can find an ASCII – text – file README.TXT, which includes changes made after printing of this user’s manual on the QUANCOM installation CD.
  • Page 42 QUANCOM INFORMATIONSSYSTEME GmbH In der Flecht 14 50389 Wesseling Wenn Sie Hilfe brauchen, erreichen Sie uns unter: QUANCOM Hotline Deutschland If you need urgent help call:QUANCOM Hotline Germany 0 22 36 / 89 92 - 20 Monday-Thursday from 9:00 to 18:00...
  • Page 43: Technical Support Form

    Complete this form before contacting QUANCOM Informationssysteme GmbH for technical support and our applications engineers may answer your questions more efficiently. If you are using any other QUANCOM hardware or software products please add them to this configuration form. Include additional pages if necessary.
  • Page 44: Hardware And Software Configuration Form

    This form helps you to list your hardware and software settings. Complete this form each time you change your software or hardware configuration, and use this form as a reference for your current configuration. Complete this form accurately before contacting QUANCOM Informationssysteme GmbH for technical support, so that our application engineers can answer your questions more efficiently.
  • Page 45: Dokumentations Formular

    Interrupt Level of other Boards Dokumentations Formular QUANCOM Informationssysteme GmbH would like you to comment on the documentation supplied with our products. This information helps us to provide you with quality products to meet your needs. Please include additional pages if necessary.
  • Page 46 ________________________________________________ Company: ________________________________________________ Address: ________________________________________________ Phone: ________________________________________________ Fax: ________________________________________________ Comment: ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ Mail to: support@quancom.de Fax to: +49 2236 89 92 49 Address: QUANCOM Informationssysteme GmbH In der Flecht 14 50389 Wesseling Germany © QUANCOM Informationssysteme GmbH...
  • Page 47: Trademarks

    CLOCK77/PCI CLOCK77/USB CLOCK77/ISA Trademarks Linux is registered trade-mark of Linus Torvalds. MS, MS-DOS, Microsoft, Visual Basic, Windows, Windows Vista/XP/2000/NT/ME/98/95 is registered trade-mark of Microsoft Corporation. XT and PS/2 are trade-marks and IBM, OS/2 and AT are registered trade-mark of International Business Machines Corporation.

This manual is also suitable for:

Clock77/usbClock77/isa

Table of Contents