Dover GROEN NHFP Operator's Manual
Dover GROEN NHFP Operator's Manual

Dover GROEN NHFP Operator's Manual

Braising pans

Advertisement

OPERATOR MANUAL
IMPORTANT INFORMATION, KEEP FOR OPERATOR
This manual provides information for:
MODELS NHFP & NHFP(E)
BRAISING PANS
· Stainless Steel
· Power Tilting
· Gas Heated
THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE.
READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND
WARNINGS CONTAINED IN THIS MANUAL.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
POST IN A PROMINENT LOCATION
Instructions to be followed in the event user smells gas.
This information shall be obtained by consulting your
local gas supplier. As a minimum, turn off the gas and
call your gas company and your authorized service agent.
Evacuate all personnel from the area.
WARNING
Improper installation, adjustment, alteration, service or
maintenance can cause property damage, injury or death.
Read the installation, operating and maintenance instructions
thoroughly before installing or servicing this equipment.
NOTIFY CARRIER OF DAMAGE AT ONCE
It is the responsibility of the consignee to inspect the container upon receipt of
same and to determine the possibility of any damage, including concealed dam-
age. Unified Brands suggests that if you are suspicious of damage to make a
notation on the delivery receipt. It will be the responsibility of the consignee to file
a claim with the carrier. We recommend that you do so at once.
Manufacture Service/Questions 888-994-7636.
Information contained in this document is known to be current and accurate at the time
of printing/creation. Unified Brands recommends referencing our product line websites,
unifiedbrands.net, for the most updated product information and specifications.
PART NUMBER 121010 REV. B (10/07)
1055 Mendell Davis Drive
Jackson, MS 39272
888-994-7636, fax 888-864-7636
groen.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GROEN NHFP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Dover GROEN NHFP

  • Page 1 OPERATOR MANUAL IMPORTANT INFORMATION, KEEP FOR OPERATOR This manual provides information for: MODELS NHFP & NHFP(E) BRAISING PANS · Stainless Steel · Power Tilting · Gas Heated THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE. READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS CONTAINED IN THIS MANUAL.
  • Page 2 OM-NHFP IMPORTANT — READ FIRST — IMPORTANT CAUTION: SHIPPING STRAPS ARE UNDER TENSION AND CAN SNAP BACK WHEN CUT. CAUTION: UNIT WEIGHS 500 TO 600 LB. (230 TO 255 KG). FOR SAFE HANDLING, INSTALLER SHOULD OBTAIN HELP AS NEEDED, OR EMPLOY APPROPRIATE MATERIALS HANDLING EQUIPMENT (SUCH AS A FORKLIFT, DOLLY, OR PALLET JACKET) TO REMOVE THE UNIT FROM THE SKID AND MOVE IT TO THE PLACE OF INSTALLATION.
  • Page 3: Table Of Contents

    OM-NHFP Table of Contents IMPORTANT OPERATOR WARNINGS ..........2 EQUIPMENT DESCRIPTION .
  • Page 4: Equipment Description

    OM-NHFP Equipment Description Groen NHFP and NHFP(E) Gas Fired Braising A fully enclosed, spring-type actuator Pans provide a stainless steel pan equipped with counterbalances the cover to keep it opened or heat transfer fins, burner/combustion chamber, closed. The cover opens to the back and is...
  • Page 5: Inspection And Unpacking

    OM-NHFP Inspection and Unpacking Cut the straps holding the unit on the skid, and The unit will arrive completely assembled, lift the unit straight up off the skid. wrapped in protective plastic on a heavy skid, in a heavy cardboard carton. Immediately upon receipt, inspect the carton for damage.
  • Page 6: Initial Start-Up

    OM-NHFP 8. In Canada, the installation must conform to CAN/CGA B149, Installation Codes for Gas Appliances and Equipment, and/or local codes. 9. The braising pan and its shutoff valve must be disconnected from the gas WARNING supply piping system during any testing ELECTRICALLY GROUND THE UNIT AT THE at pressures in excess of ½...
  • Page 7: Operation

    OM-NHFP Operation A. Controls Operator controls for the Braising Pans are: 1. The thermostat dial, located on the control console to the right of the pan body. This dial is used to turn the thermostat on or off and to set the thermostat for pan temperatures between and 425 2.
  • Page 8 OM-NHFP (c) Disconnect the electrical (2) Set the thermostat to "OFF". power from the unit. (3) Depress the knob on the Combination Control and turn it clockwise to "OFF". (4) Wait 5 minutes, then proceed as instructed at "To Start Pan" WARNING above.
  • Page 9: Sequence Of Operation

    OM-NHFP 4. To Move a Unit on Casters 2. Leave the cover vent open to let excess steam escape. For long simmering The unit must be anchored with a cable operations, you may wish to close the or chain to avoid accidentally breaking or vent.To check cooking progress when pulling loose the gas connection.
  • Page 10 OM-NHFP for sixty seconds heats the thermopile to The thermostat controls heating by operating temperature, so the thermopile alternately calling for flames at the full begins to provide electric current at 750 capacity of the main burner and then millivolts. Electricity from the thermopile signaling the control to shut the burner powers the control circuit and the off completely.
  • Page 11: Cleaning

    OM-NHFP Cleaning abrasive materials or metal implement that might scratch the surface, because scratches make the pan hard to clean and provide places for bacteria to grow. Do NOT use steel wool, which may leave particles imbedded in the pan surface and cause eventual WARNING corrosion and pitting.
  • Page 12: Maintenance

    OM-NHFP agent from your supplier of sanitizing products. Following the supplier's instructions, apply the sanitizing agent after the unit has been cleaned and drained. Rinse off the sanitizer thoroughly. 9. If there is difficulty removing mineral deposits or a film left by hard water or food residues, clean the pan thoroughly and then use a deliming agent, like Lime-Away from ECOLAB, in accordance with the...
  • Page 13: Troubleshooting

    OM-NHFP Troubleshooting Your Groen Braising Pan will operate smoothly and efficiently if properly maintained. However, the following is a list of checks to make in the event of a problem. If the actions suggested do not solve the problem, call your qualified Groen Service Representative. For the phone number of the nearest agency, call your area Groen representative or the Groen Parts and Service Department.
  • Page 14 OM-NHFP WHAT TO CHECK SYMPTOM • indicates items which must be performed by an authorized technician. Model NHFP with Thermopile Ignition System Pilot will not light. User Lighting procedure, to ensure that the instructions in the Operation section of this manual are followed •...
  • Page 15 OM-NHFP WHAT TO CHECK SYMPTOM • indicates items which must be performed by an authorized technician. Burner does not come Auth Service Voltage across the terminals of the gas valve solenoids. If on, but the igniter heats. Rep Only 24 VAC is present, replace the gas valve assembly. If not, •...
  • Page 16 OM-NHFP OM-NHFP...
  • Page 17: Parts List

    Parts List To order parts, contact your authorized Groen Service Agency. Supply the model designation, part description, part number, quantity, and, where applicable, voltage and phase. Description Part No. Description Part No. 1, 2 Actuator Cover 014085 Igniter, 24V 088254 Spring 012533 Ignition Control 24V...
  • Page 18 OM-NHFP Cover Hinges and Actuator Part No. Description Size 3 Pan Size 4 Pan Stud-Weld 012590 012590 Hinge, Cover 013485 013485 Bracket, Cover Attachment 013277 013277 Actuator Assembly 014085 014085 Nut, Dome 005471 005471 Bracket, Hinge 054876 004556 Nut, Hex, 5/16 - 18 003823 003823 Washer, Lock 5/16...
  • Page 19 OM-NHFP Model NHFP(E) with Electronic Coil Ignition Wiring Diagram for units built before May, 1991 Wiring Diagram for units built after April, 1991 OM-NHFP...
  • Page 20 OM-NHFP Model NHFP with Standing Pilot Wiring Diagram Carborundum Igniter Assembly OM-NHFP...
  • Page 21: References

    OM-NHFP References American Gas Association Laboratories National Fire Protection Association 8501 East Pleasant Valley Rd. 60 Battery March Park Cleveland, Ohio 44131 Quincy, Massachusetts 02269 Z223.1-1984 National Fuel Gas Code NFPA/54 Installation of Gas Appliances & Gas Piping American National Standards Institute NFPA/70 The National Electrical Code 1403 Broadway...
  • Page 22 OM-NHFP Service Log Model No. ______________________________ Purchased From _________________________ Serial No. ______________________________ Location _______________________________ Date Purchased _________________________ Date Installed ___________________________ Purchase Order No. ______________________ For Service Call _________________________ Date Maintenance Performed Performed by OM-NHFP...
  • Page 23: Warranty

    OM-NHFP Warranty Limited Warranty To Commercial Purchasers * (Domestic U.S., Hawaii & Canadian Sales Only) Groen Foodservice Equipment ("Groen Equipment") has been skillfully manufactured, carefully inspected and packaged to meet rigid standards of excellence. Groen warrants its Equipment to be free from defects in material and workmanship for (12) twelve months with the following conditions and subject to the following limitations.
  • Page 24 1055 Mendell Davis Drive • Jackson MS 39272 888-994-7636 • 601-372-3903 • Fax 888-864-7636 groen.com PART NUMBER 121010 REV. B (10/07)

This manual is also suitable for:

Groen nhfp(e)

Table of Contents