Installation Instructions SS2520 SS2570
General Note: This product is to be installed by a licensed plumber, installation must comply with AS/NZS 3500 and
local plumbing codes.
Pressures & Temperatures
Maximum Hydrostatic Pressure – 500 kpa. (As per AS/NZS3500)
Note: AS/NZS 3500.1-2003 (Clause 3.3.4) states that "Provision shall be made to ensure that the
maximum static pressure at any outlet, other than a fire service outlet, within a building does not
exceed 500 kPa.
Note: Pressures above 500kPa can cause damage from water hammer, reduced life of appliances,
taps and fittings, and cause excessive noise in the system.
Minimum Hydrostatic Pressure – 100 kpa
The Maximum operating temperature for the Mixer Tap is 65
Please ensure that the lines are flushed prior to installation as contaminates in the water can damage the
Ceramic Cartridge, flow regulator and also affect the performance of the Mixer.
N.B This mixer is designed to have the Handle to the right hand side of the mixer, doing so will put the cold inlet to the
front of the mixer, the purpose is to assist with accidental scalding if a child pulls the handle forward trying to turn on
the mixer, installing the handle to the centre will put the cold on the left hand side which is not recommended.
1. Remove product from packaging and check for damages, if the product is damaged do not install and return
to store of purchase.
2. The WELS compliant aerator has been pre-assembled into the mixer outlet. To comply with WELS the flow
regulated aerator must remain in place.
3. Ensure Product is complete as per exploded drawing.
4. A single 35mm Hole is required in the mounting surface.
5. The maximum mounting surface thickness cannot exceed 37mm.
6. Ensuring bench sealing washer (A) is in place on base of Mixer.
7. Screw the Mixer tails (B) into base of the Mixer being careful to avoid damage to the o'ring seals, the Mixer
inlet ports are colour coded, Red for hot and Blue for cold.
8. Feed the Mixer tails through the Mounting surface, each end alternatively and position the mixer on the
mounting surface ensuring the sealing washer (A) is positioned correctly.
9. Feed Mixer tails, each alternatively through Stabiliser Plate (C).
10. Slide Rubber Washer (D) onto Mixer thread followed by Metal Washer (E).
11. Using Fixing Nut (F) tighten Mixer to mounting Surface, lock Fixing nut in place with screws (G)
12. Connect Mixer tails to Mains Water supply line.
13. Ensure the Mixer tails are not Kinked, Bent, stretched or twisted when assembling to the Mains Water Supply.
The Mixer Tail connection between the mixer and the Water supply must have a natural curve.
14. Ensure Mixer tails are not exposed to Abrasions, corrosive agents or alike.
15. It is recommended that In-Line filters be installed to ensure a cleaner flow of water to the mixer.
To the consumer
1. The Mixer is to only be cleaned with warm soapy water.
2. Under No Circumstances should any abrasive, cream or acid based cleaning agents be used as these types
of cleaners will damage the chrome finish, Cartridge, seals and aerators.
o